In this work, we are obviously interested in a general solution for the calculation of the image of a single bar in partially coherent illumination. The solution is based on the theory of Hopkins for the formation of images in optical instruments in which it was shown that for all practical cases, the illumination of the object may be considered as due to a self – luminous source placed at the exit pupil of the condenser , and the diffraction integral describing the intensity distribution in the image of a single bar – as an object with half – width (U0 = 8 ) and circular aperture geometry is viewed , which by suitable choice of the coherence parameters (S=0.25,1.0.4.0) can be fitted to the observed distribution in various types of microscope , the aberration were restricted to defocusing and coma upto third – order , the method of integration was Gauss quadrature: The necessary set of integration depends , of course , on the amount of present aberrations and had to be chosen (20) points of Gauss which decrease the computation time to few seconds: The aberration free systems corresponding to the paraxial receiving plane (W20= 0.0) is especially interesting as it predicts diffraction pattern shape. The influence of defocusing is very pronounced and relatively distorts the object , the influence of the off – axis aberration (third – order coma ), in which it was shown that for the high peaks in the images are most noticeable in the region of almost perfect coherence (S=0.25). As (S) is increased from (0.25) to (1.0) there is a pronounced redistribution of intensity, with peaks moving from one side of the image to the other. Calculations were also performed for systems having spherical aberration, but the results are qualitatively similar to an aberration – free defocused system and are omitted, so we will not present any numerical results. A computer program was written in FORTRAN 77 which solved the modified intensity distribution of Hopkins for(U´) dimensionless distance. The advantage of that additional work on this class of problems to investigate the development of more efficient numerical methods, also the reduction in computation time to few seconds for data runs for individual curves of intensity.
Compression for color image is now necessary for transmission and storage in the data bases since the color gives a pleasing nature and natural for any object, so three composite techniques based color image compression is implemented to achieve image with high compression, no loss in original image, better performance and good image quality. These techniques are composite stationary wavelet technique (S), composite wavelet technique (W) and composite multi-wavelet technique (M). For the high energy sub-band of the 3rd level of each composite transform in each composite technique, the compression parameters are calculated. The best composite transform among the 27 types is the three levels of multi-wavelet
... Show MoreInformation hiding strategies have recently gained popularity in a variety of fields. Digital audio, video, and images are increasingly being labelled with distinct but undetectable marks that may contain a hidden copyright notice or serial number, or even directly help to prevent unauthorized duplication. This approach is extended to medical images by hiding secret information in them using the structure of a different file format. The hidden information may be related to the patient. In this paper, a method for hiding secret information in DICOM images is proposed based on Discrete Wavelet Transform (DWT). Firstly. segmented all slices of a 3D-image into a specific block size and collecting the host image depend on a generated key
... Show MoreMedian filter is adopted to match the noise statistics of the degradation seeking good quality smoothing images. Two methods are suggested in this paper(Pentagonal-Hexagonal mask and Scan Window Mask), the study involved modified median filter for improving noise suppression, the modification is considered toward more reliable results. Modification median filter (Pentagonal-Hexagonal mask) was found gave better results (qualitatively and quantitatively ) than classical median filters and another suggested method (Scan Window Mask), but this will be on the account of the time required. But sometimes when the noise is line type the cross 3x3 filter preferred to another one Pentagonal-Hexagonal with few variation. Scan Window Mask gave bett
... Show MoreObjectives: study the relation between the effect of time (long time duration) with high concentration of iodine
and study its effect on the activity of the thyroid gland (hormonal and histological changes).
Methodology: An experimental study was done on (30) albino rats (8 weeks of age) to know the effect of high
concentration of iodine on the activity of the thyroid gland (hormonal and histological changes) related with
time. The study last for six months for the period of 1/2/2007 to 31/7/2007, the experiment was carried out in the
research lab. of pathology department, College of Medicine, University of Baghdad.
Results: The study shows changes in hormonal levels of thyroid hormones (T3 & T4) and also histologic
The adhesion strength between Polyethylene (PE) film and Aluminum surface by using the adhesive material (Cyanoacrylate) has been studied. Aluminum (Al) was used as a substrate, and polyethylene (PE) was used as a film adhered to the Al surface. Standard specimens were prepared to use in the peeling test in dry condition, other specimens were immersed in water for 12 days at room temperature. the results for the specimens in the dry condition had shown that high value in the peel force and the peel energy, the peel force was 0.38*103 N/m and the peel energy was 0.605*103 N/m, peeling the film from Al surface leaves a residual of the adhesive material on both adherend, the failure for this specimen were combination of adhesive and cohesive f
... Show MoreObjectives: study the relation between the effect of time (long time duration) with high concentration of iodine
and study its effect on the activity of the thyroid gland (homonal and histological changes).
Methodology: An experimental study was done on (30) albino rats (8 weeks of age) to know the effect of high
concentration of iodine on the activity of the thyroid gland aiormonal and histological changes) related with
time. The study last for six months for the period of I/2/2007 to 31/7/2007, the experiment was carried out in the
research lab. of pathology deparment, College of Medicine, University of Baghdad.
Results: The study shows changes in homonal levels of thyroid hormones (T3 & T4) and also histological<