In this study, phytoplankton density, chlorophyll-a, and selected physico- chemical parameters were investigated in Erbil wastewater channel. The surveys were carried out monthly from May 2003 to April 2004. Samplings were established on three sites from headwaters to the mouth. The results showed that pH was in alkaline side of neutrality, with significant differences (P<0.05) between sites 1 and 3. TSS concentration decreased from site 1 toward site 2 (mean value, 80.15 to 25.79 mg.l-1). A clear gradual increase in mineral content (TDS) observed from site one of the channel towards the mouthpart. Soluble reactive phosphate has a concentration maximum mean value reached 48.4 µg.l-1 which is recorded in site 2. A high positive relationship (P<0.01, r =0.449) obtained between phosphate concentration and phytoplankton density. The results of chlorophyll-a concentration were (mean values, 2.26, 3.88 and 2.42 µg.l-1 respectively), showed the positive relationship (P<0.05, r =0.012) with phytoplankton density. The PCA produced three significant main components which represented by more than 64.5% of the total variance, namely, nutrients related to algal productivity; disposal wastewater and storm water runoff, in which explained by 31.29, 19.68 and 13.55% respectively of the total variance of water quality in polluted channel.
In this study water quality was indicated in terms of Water Quality Index that was determined through summarizing multiple parameters of water test results. This index offers a useful representation of the overall quality of water for public or any intended
use as well as indicating pollution, which are useful in water quality management and decision making. The application of Water Quality Index (WQI) with ten physicochemical water quality parameters was performed to evaluate the quality of Euphrates River water for drinking usage. This was done by subjecting the water samples collected from seven stations within Al-Anbar province during the period 2004-2010 to comprehensive physicochemical analysis. The ten physicochemical paramete
Six house-hold Abyssinian pumps distributed in different villages of Mansoura (Mans-I, Mans-II and Mans-III) and Talkha (Talk-I, Talk-II and Talk-III) cities, Egypt, have been selected for regular seasonal water quality assessment during 2017. Water samples have been collected within the mid-periods of four seasons Standard assessment tools were employed for the integrated water quality assessment including Water Quality Index (WQI) and ISO standard algal toxicity test. WQI displayed remarkable local and seasonal variations with excellent (≥ 90) and good (70 - 89) only recorded for water samples collected from Mans-I pump located in sparsely populated area and far 50 meters only from the eastern (Damietta) branch of Nile River. WQI of
... Show MoreFinancial Reporting Quality (FRQ) is one of the important topics in the financial management, it has the impact on the users decisions, it also effect on many other variables i.e dividend, therefore. This paper aims to provide a diameter of Financial Reporting Quality (FRQ) level for the companies listed on the Iraqi Stock Exchange. It also tries to show the FRQ effects on the dividend policy. The study sample was 13 listed companies in the Iraqi Stock Exchange for the period from 2007 to 2011. Kothari et al. 2005 model has been used to measure the FRQ, on the other hand the common stock share of the dividend was used to measure the dividend.
Many conclusions have been driven by the research
... Show MoreThe research dealt with the issue of strategic information systems and its impact on the global marketing channel. As the research aims to know the strategic information systems used in the cement company. Which support the senior management in supporting decisions taken in the process of global orientation and moving to foreign markets by choosing the marketing channel that will suit the company. Product and competition with it. With other companies' products. The problem of the study focused on how to move to global markets, and any marketing channel that can be followed to move the cement product globally, what are the strategic information systems used in the company and how will it contribute to supporting senior management dec
... Show MoreThis study aims to assess the removal efficiency andestablish the BOD5 and COD statisticalcorrelation of the sewage flowing in Al-Diwaniyah wastewater treatment plant in Iraq during the study period (2005-2016). The strength of the influent wastewater entering the plant varied from medium to high in strength. High concentrations of BOD5 and COD in the effluent were obtained due to the poor performance of the plant. This was observed from the BOD5 /COD ratios that did not confirm with the typical ratios for the treated sewage. To improve the performance of this plant, regression equations for BOD5 and COD removal percentages were suggested which can be used to facilitate evaluation of liquid waste and optimal control process. The equations
... Show MoreHeat transfer performance of two horizontal parallel plates subjected to discrete heating from the upper plate is studied and analyzed under the condition of different gap size between the heating elements with water as the working fluid. The investigation includes the variation of Reynolds number and the heat flux along with the position of the heating elements to discover the effect of different boundary conditions on the gap size variation. Results show that gap size between the heating elements has a crucial impact on the heat transfer process inside the channel, when the gap size increased a remarkable enhancement is achieved. This result is also confirmed with the investigated range of Reynolds number and the heating value. Results al
... Show MoreThis research studied the effect of magnetized water in concrete preparation and its effect on the presenting of cement in concrete mixtures also to find the ability of reducing the amount of cement in preparing one cubic meter, this is not exceed than 10% in one mixture , The experiments showed the preparation of standard cubes from the concrete which was used two kind of water magnetized water which was prepared by passing the tap water through the systems of different magnetic strength in terms of (6000,9000) Gauss and the ordinary water . The velocity of water through the magnetic field, which gives us the highest value for the compressive strength, was up to 1m/sec. to determine the best magnetic intensity, we examined The comp
... Show MoreElectro coagulation treatment was used for zinc removal from electroplating wastewater of the State Company for Electrical Industries . This wastewater, here consists zinc ions with maximum concentration in solution of 90 ppm .
The parameters that influenced the wastewater treatment are: current density in the range 1-1.4 mA/cm2, pH in the range 5-10, temperature in the range 25-45°C and time in the range 10-180 minute.
The research is a laboratory experimental type using batch system for electrical process with direct current. The cell comprised of aluminum electrode as anode and stainless steel electrode as cathode. Thirty experiments and one hundred fifty sample lab tests were carried out in this research
... Show MoreThe aim of this study is to know the effect of different percentages of chitosan added to drinking water on the weight and quality of quail meat, physical anatomy in terms of (the body of the long carcass, the girth of the chest, the length of the thigh bones, the thigh racket, the fullness of the chest), chemical analysis (protein, moisture, fat and ash) and sensory evaluation of quail meat. It was purchased 320 Iraqi-origin birds of quail and one day old. Chicks were randomly distributed to three equal groups' treatments and treated with chitosan and added to the drinking water: the first treatment (0.1 gm./L water only as a control treatment), the second treatment (0.2 gm./L of chitosan was added to the drinking water) and the
... Show More