Preferred Language
Articles
/
bijps-671
The Impact of Two Doses of Vitamin K2 (Menaquinone-7) on Doxorubicin-Induced Hepatotoxicity in Rats
...Show More Authors

The objective of this study was to evaluate the impact two doses of Menaquinones-7 on hepatotoxicity induced by doxorubicin in rats. Sixty adult rats of both sexes were used in this study; the animals were randomly enrolled into six groups of 10 animals each. Group I: negative control (rats administered distilled water); Group II: Menaquinones-7 at a dose of  16 µg/kg; Group III: Menaquinones-7 at a dose of 48 µg/kg; Group IV: positive control (Doxorubicin 15 mg/kg); Group V: Menaquinones-7 at a dose of 16 µg/kg administered prior to a single dose of Doxorubicin 15 mg/kg; Group VI: Menaquinones-7 at a dose of 48 µg/kg administered prior to a single dose of  Doxorubicin 15 mg/kg. On day twelve of the study, blood was collected for serum preparation for the estimation of alanine aminotransferase (ALT), alkaline phosphatase (ALP), and total bilirubin (TB). The liver of each animal was excised for histological examination. High dose of MK-7 significantly (P<0.05) decreased serum ALT, ALP, and TB and there was an improvement in the histopathological lesions of the liver in group V and group VI compared to group IV. In conclusion, MK-7 may have protective effect against Dox-induced hepatotoxicity in rats.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Oct 01 2010
Journal Name
Iraqi Journal Of Physics
Effect ofweight percentage chopped carbon fibers on the mechanism of cracks propagation for Epoxy composites
...Show More Authors

In this research, the mechanism of cracks propagation for epoxy/ chopped carbon fibers composites have been investigated .Carbon fibers (5%, 10%, 15%, and 20%) by weight were used to reinforce epoxy resin. Bending test was carried out to evaluate the flexural strength in order to explain the mechanism of cracks propagation. It was found that, the flexural strength will increase with increasing the percentage weight for carbon fibers. At low stresses, the cracks will state at the lower surface for the specimen. Increasing the stresses will accelerate the speed of cracks until fracture accorded .The path of cracks is changed according to the distributions of carbon fibers

View Publication Preview PDF
Publication Date
Sun Dec 09 2018
Journal Name
Baghdad Science Journal
A Comparative Study on the Electrical Characteristics of Generating Plasma by Using Different Target Sources
...Show More Authors

In this research, the electrical characteristics of glow discharge plasma were studied. Glow discharge plasma generated in a home-made DC magnetron sputtering system, and a DC-power supply of high voltage as input to the discharge electrodes were both utilized. The distance between two electrodes is 4cm. The gas used to produce plasma is argon gas which flows inside the chamber at a rate of 40 sccm. The influence of work function for different target materials (gold, copper, and silver), - 5cm in diameter and around 1mm thickness - different working pressures, and different applied voltages on electrical characteristics (discharge current, discharge potential, and Paschen’s curve) were studied. The results showed that the discharge cur

... Show More
View Publication Preview PDF
Scopus (21)
Crossref (14)
Scopus Clarivate Crossref
Publication Date
Mon Dec 03 2012
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
The Effect of Window Size Changing on Satellite Image Segmentation Using 2D Fast Otsu Method
...Show More Authors

Publication Date
Wed Jan 01 2020
Journal Name
Aip Conference Proceedings
Effect of BaTio3 mixture on the structural, electrical properties and morphology for PET/ BaTiO3 composite
...Show More Authors

In the present work, the focusing was on the study of the x-ray diffraction, dielectric constant, loses dielectric coefficient, tangent angle, alter- natively conductivity and morphology of PET/BaTio3. The PET/BaTio3 composite was prepared for polyethylene terephthalate PET polymer composite containing 0, 10, 20, 30, 40, 50, and 60 wt. % from Barium titanate BaTi03 powder. The composite of two materials leads to form mixing solution and hot-pressing method. The effect of BaTio3 on the structure and dielectric properties with morphology was studied on PET matrix polymer using XRD, LCR meter and SEM.

View Publication Preview PDF
Scopus (3)
Scopus Clarivate Crossref
Publication Date
Fri Jun 20 2025
Journal Name
Baghdad Science Journal
The Role of Fear and Predator Dependent Refuge on a Stage Structure Prey-Predator System
...Show More Authors

The present paper investigates the role of fear and predator dependent refuge in the prey-predator system. The system describes the interaction between prey and a stage structure of predator that incorporates Holling II functional response. The predator splits into two compartments immature (juvenile) and mature (adult). The mature predators can hunt and reproduce but this capability is not found in the immature predators, the immature depend on their parents. The growth rate of prey decreases due to the existence of mature predators. The existence, uniqueness, and boundedness of the solution of the system are investigated. Three equilibrium points of the system are determined. The local stability of the system is studied. The global stabil

... Show More
View Publication
Scopus Clarivate Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Aip Conference Proceedings
Fast lightweight encryption device based on LFSR technique for increasing the speed of LED performance
...Show More Authors

LED is an ultra-lightweight block cipher that is mainly used in devices with limited resources. Currently, the software and hardware structure of this cipher utilize a complex logic operation to generate a sequence of random numbers called round constant and this causes the algorithm to slow down and record low throughput. To improve the speed and throughput of the original algorithm, the Fast Lightweight Encryption Device (FLED) has been proposed in this paper. The key size of the currently existing LED algorithm is in 64-bit & 128-bit but this article focused mainly on the 64-bit key (block size=64-bit). In the proposed FLED design, complex operations have been replaced by LFSR left feedback technology to make the algorithm perform more e

... Show More
View Publication
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Tue Dec 10 2024
Journal Name
Mesopotamian Journal Of Cybersecurity
Development of Robust and Efficient Symmetric Random Keys Model based on the Latin Square Matrix
...Show More Authors

Symmetric cryptography forms the backbone of secure data communication and storage by relying on the strength and randomness of cryptographic keys. This increases complexity, enhances cryptographic systems' overall robustness, and is immune to various attacks. The present work proposes a hybrid model based on the Latin square matrix (LSM) and subtractive random number generator (SRNG) algorithms for producing random keys. The hybrid model enhances the security of the cipher key against different attacks and increases the degree of diffusion. Different key lengths can also be generated based on the algorithm without compromising security. It comprises two phases. The first phase generates a seed value that depends on producing a rand

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (1)
Scopus Crossref
Publication Date
Fri Nov 01 2019
Journal Name
International Journal On Interactive Design And Manufacturing (ijidem)
A real-time automated sorting of robotic vision system based on the interactive design approach
...Show More Authors

View Publication
Scopus (41)
Crossref (32)
Scopus Clarivate Crossref
Publication Date
Mon Mar 13 2017
Journal Name
Journal Of Baghdad College Of Dentistry
The Effect Of Treatment Protocol and Implant Dimensions on Primary Stability Utilizing Resonance Frequency Analysis
...Show More Authors

ABSTRACT Background: According to Branemark’s protocol, the waiting period between tooth extraction and implant placement is 6–8 months; this is the late placement technique. Achieving and maintaining implant stability are prerequisites for a dental implant to be successful. Resonance Frequency Analysis (RFA) is a noninvasive diagnostic method that measures implant stability. The aim of this study was to investigate the influence of treatment protocol and implant dimensions on primary implant stability utilizing RFA. Materials and methods: This study included 63 Iraqi patients (37 male, 26 female; ranging 22-66 years). According to treatment protocol, the sample was divided into 2 groups; A (delayed) & B (immediate). Dental im

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Oct 30 2023
Journal Name
Digest Journal Of Nanomaterials And Biostructures
Concentration effect on the vibrational and electronic properties of MgXZn7-XO7 wurtzoids nanostructure via DFT
...Show More Authors

In the present work, the ternary compound MgxZn7-x O7Wurtzoid with variable Zn and Mg contents was analyzed using density functional theory with B3LYP 6-311G**basis set. The electronic and vibrational properties of MgxZn7-xO7 wurtzoids, were investigated, including energy gaps, bond lengths, spectral properties, such like infrared spectra and Raman. IR and Raman spectra were compared with experimental longitudinal optical modes frequency results. The theoretical results agree well with experiments and previous data. It has been found that the energy gap is increasing with the increased Mg concentration, and that the longitudinal optical position exposes a UV shift movement with an increase in the concentration.

View Publication
Scopus (3)
Crossref (2)
Scopus Clarivate Crossref