Econazole nitrate (EN) is considered as the most effective agent for the treatment of all forms of dermatomycosis caused by dernatophytes. It was formulated as a topical solution in our laboratories. This study was designed to evaluate the effectiveness of Econazol Nitrate in the prepared formula and compared with that of commercial brand, Pevaryl®. A total of 104 patient suffering from dermatomycoses were involved in this investigation. Both formula were applied to the affected skin region in the morning and evening from week to 16 weeks with light massage until complete healing effect was achieved. The data revealed that the percentage of cured patient treated with the prepared formula and reference formula of Ecanozol Nitrate 1% solution were 90.3% and 88.4% respectively also chronic cases could be largely cured by treatment with the prepared formula Econazol Nitrate 1% solution. The results of this clinical investigation showed that the prepared formula of Ecanozol nitrate 1% was effective as compared to that of the commercial brand, Pevaryl®.
Amebiasis, related to the pathogenic parasite Entamoeba histolytica, is a prominent cause of diarrhea globally. Amebiasis is primarily a disease of impoverished communities in developing nations, although it has recently arisen as a significant infection among returning tourists and immigrants. Severe cases are linked to a high case fatality rate. Although polymerase chain reaction (PCR)-based diagnosis is becoming more widely available, it is still underutilized. Treatment with nitroimidazoles is now suggested, however novel parasite medication research is a top priority. To avoid problems, amebiasis should be considered before corticosteroid therapy. Because there is no effective vaccination, sanitation and availability to clean w
... Show MoreAmebiasis, related to the pathogenic parasite Entamoeba histolytica, is a prominent cause of diarrhea globally. Amebiasis is primarily a disease of impoverished communities in developing nations, although it has recently arisen as a significant infection among returning tourists and immigrants. Severe cases are linked to a high case fatality rate. Although polymerase chain reaction (PCR)-based diagnosis is becoming more widely available, it is still underutilized. Treatment with nitroimidazoles is now suggested, however novel parasite medication research is a top priority. To avoid problems, amebiasis should be considered before corticosteroid therapy. Because there is no effective vaccination, sanitation and availability to clean w
... Show MoreThe bacterial isolates were obtained from Al-Kindi Hospital were diagnosed by the Vitek-2 system and re confirm by 16srRNA gene as S. aurous, the results were shown 20 isolates (66.7%) out of 30 isolates were positive to protease production. All bacterial isolates (100%) were sensitive to Gentamicin and Levofloxacin. but resistant (100%) to aztreonam. The best temperature for enzyme production from bacteria was 37 °C, and the best pH for enzyme production was 7. Partial purification of the bacterial enzyme (protease) was carried out using short steps included ammonium sulfate 65% saturation, ion exchange using DEAE- cellulose column and then applied on gel filtration chromatography using Sephadex G-200 column. The enzymatic activit
... Show MoreAtotal of 75 different clinical samples were collected from different hospitals in Baghdad Biochemical and morphological characterization tests showed that forty isolates were identified as Staphylococcus aureus Antibiotic susceptibility tests of all isolates towards ten antibiotics were carried out and results showed that many isolates (97.5 %) were resistant to ?-lactam antibiotic , 70 % were resistant to Tetracyclinee , 62.5% were resistant to co-trimoxazole , 60 % were resistant to ciprofloxacin , 55% were resistant both of chloramphenicol and erythromycin , 52.5% were resistant to gentamicin , 35% were resistant to rifampicin , 10% were resistant to vancomycin . According to the above results the S.aureus I1 which is isolated
... Show MoreBackground: The new concepts and technologies continue to change the dynamics of endodontic practices in the world. Rapid and significant changes in techniques, instrument design, and the type of metals used to manufacture endodontic instruments which have been made during the last few years in an attempt to overcome canal preparation errors. The purpose of this study is to measure and compare canal transportation and centering ability of Self Adjusting File with two rotary nickel-titanium (Ni-Ti) systems, ProTaper and BioRaCe at different levels. Material and Methods: Forty five distal roots of mandibular first molars with moderate curvature were selected using Schneider method. Roots were divided randomly into 3 groups of 15 each and were
... Show MoreBackground: The accuracy of fitness of any dental casting is imperative for the success of any prosthodontic treatment. From the time that dental casting was first introduced, efforts have been made to produce more accurate and better fitted castings with minimal marginal discrepancy. The aim of this in vitro study was to evaluate the effects of three different investing and burnout techniques on the vertical marginal discrepancies ofceramometalcopings invested with two types of phosphate- bonded investments. Materials and methods: Sixty wax patterns were fabricated on a standardized prepared brass die representing an upper central incisor by the aid of a custom-made split mold. Three different investing and burnout techniques were applied
... Show MoreDesalination is a process where fresh water produces from high salinity solutions, many ways used for this purpose and one of the most important processes is membrane distillation (MD). Direct contact membrane distillation (DCMD) can be considered as the most prominent type from MD types according to ease of design and modus operandi. This work studies the efficiency of using DCMD operation for desalination brine with different concentration (1.75, 3.5, 5 wt. % NaCl). Frame and plate cell was used with flat sheet PTFE hydrophobic type membrane. The study proves that MD is an effective process for desalination brines with feed temperature less than 60˚C especially for feed with low TDS. 37˚C, 47˚C, and 57˚C was feed t
... Show MoreThe aim of the study was to evaluate the efficacy of diode laser (λ=940 nm) in the management of gingival hyperpigmentation compared to the conventional bur method. Materials and methods: Eighteen patients with gingival hyperpigmentation were selected for the study with an age between 12-37 years old. The site of treatment was the upper gingiva using diode laser for the right half and the conventional method for the left half. All patients were re-evaluated after the following intervals: 3 days, 7 days, 1 month and 6 months post-operation. Pain and functions were re-evaluated in each visit for a period of 1 day, 3 days and 1 week post-operation. Laser parameters included 1.5 W in continuous mode with an initiated tip (400 μm) placed in
... Show MoreBackground/aim: The rising challenge of microbial resistance necessitates the development of novel therapeutic agents. This study aims to synthesize, characterize, and evaluate the antimicrobial potential of a new series of mixed-ligand metal complexes (ZnII, CuII, NiII, and MnII) derived from a p-hydroxybenzaldehyde-4-aminoantipyrine Schiff base and 2,2′-bipyridine, in addition to assessing the binding affinity and pharmacokinetic properties of the synthesized free Schiff base ligand through molecular docking and ADME profiling. Methods: The Schiff base ligand and its transition metal complexes were synthesized and subsequently characterized using single-crystal X-ray diffraction, elemental analysis, FTIR, UV–Vis spectroscopy, NMR, mag
... Show MoreIn the present work the performance of semifluidized bed adsorber was evaluated for removal of phenolic compound from wastewater using commercial activated carbon as adsorbent. P-chlorophenol (4-Chlorophenol) and o-cresol (2-methylphenol) was selected as a phenolic compound for that purpose. The phenols percent removal, in term of breakthrough curves were studied as affected by hydrodynamics limitations which include minimum and maximum semifluidization velocities and packed bed formation in the column by varying various parameters such as inlet liquid superficial velocity (from Uminsf to 8Uminsf m/s), and retaining grid (sometimes referred to as adsorbent loading) to initial static bed height ratio (from 3-4.5). In
... Show More