ABSTRACT:
Microencapsulation is used to modify and retard drug release as well as to overcome the unpleasant effect
(gastrointestinal disturbances) which are associated with repeated and overdose of ibuprofen per day.
So that, a newly developed method of microencapsulation was utilized (a modified organic method) through a
modification of aqueous colloidal polymer dispersion method using ethylcellulose and sodium alginate coating materials to
prepare a sustained release ibuprofen microcapsules.
The effect of core : wall ratio on the percent yield and encapsulation efficiency of prepared microcapsules was low, whereas
, the release of drug from prepared microcapsules was affected by core: wall ratio ,proportion of coating material and
presence of additive(PEG4000). The 2:1 core : wall ratio was compared (in weight equivalent to 300mg and 600mg drug)
with Fenbid® spansule capsule 300mg and Balkaprofen® tablet 600mg respectively. It was found that the release of drug
from selected ratio and Balkaprofen® tablet was more or less similar(P 0.05) .This sustained release ratio was
encapsulated in weight equivalent to 300mg drug to be administered once daily (600mg) as two capsules as the reference.
The capsules were stable within 6 months of storage at room temperature.
The research aims to apply a modified SERVQUAL model to evaluate the quality of the educational services via conducting exploratory research for students from the College of Administration and Economics- Department of Business Administration- Evening studies at the University of Baghdad. Questionnaire of two parts was distributed to a sample of (72) students out of (720) students of the 2nd.,3rd. and 4th. year in the beginning of the second semester of the year 2008-2009 to measure the expectations and perceptions to the quality of the educational services. Five major dimensions were analyzed to see the gaps for (22) variables. The study concluded that there were (13) variables confirmed that the
... Show MoreA simple, rapid and sensitive spectrophotometric method has been developed for the determination of captopril in aqueous solution. The method is based on reaction of captopril with 2,3-dichloro 1,4- naphthoquinon(Dichlone) in neutral medium to form a stable yellow colored product which shows maximum absorption at 347 nm with molar absorptivity of 5.6 ×103 L.mole-1. cm-1. The proposed method is applied successfully for determination of captopril in commercial pharmaceutical tablets.
A sensitive spectrofluorimetric method for the determination of glibenclamide in its tablet formulations has been proposed. The method is based on the dissolving of glibenclamide in absolute ethanol and measuring the native fluorescence at 354 nm after excitation at 302 nm. Beers law is obeyed in the concentration of 1.4 to 10 µg.ml-1 of glibenclamide with a limit of detection (LD) of 0.067 µg.ml-1 and a standard deviation of 0.614. The range percent recoveries (N=3) is 94 - 103.
A UV-Vis spectrophotometry method was developed for the determination of metoclopramide hydrochloride in pure and several pharmaceutical preparations, such as Permosan tablets, Meclodin syrups, and Plasil ampoules. The method is based on the diazotization reaction of metoclopramide hydrochloride with sodium nitrate and hydrochloric acid to yield the diazonium salt, which is then reacted with 3,5-dimethyl phenol in the presence of sodium hydroxide to form a yellow azo dye. Calibration curves were linear in the range from 0.3 to 6.5 µg/mL, with a correlation coefficient of 0.9993. The limits of detection and quantification were determined and found to be 0.18 and 0.61 µg/mL, respectively. Accuracy and precision were also determined b
... Show MoreA single step extraction-cleanup procedure using porous membrane-protected micro-solid phase extraction (μ-SPE) in conjunction with liquid chromatography–tandem mass spectrometry for the extraction and determination of aflatoxins (AFs) B1, B2, G1 and G2 from food was successfully developed. After the extraction, AFs were desorbed from the μ-SPE device by ultrasonication using acetonitrile. The optimum extraction conditions were: sorbent material, C8; sorbent mass, 20 mg; extraction time, 90 min; stirring speed, 1000 rpm; sample volume, 10 mL; desorption solvent, acetonitrile; solvent volume, 350 μL and ultrasonication period, 25 min without salt addition. Under the optimum conditions, enrichment factor of 11, 9, 9 and 10 for AFG2, AFG1
... Show MoreThe university press is an essential pillar in building an academic community to achieve its objectives in the service of society. Since the university press is a means of university media, which is issued by the departments or units of media in Iraqi universities as academic governmental-institutions, so it highlights the activities of the university and link them to its internal society in the first place as the university press is a mirror of the university and its voice is sincerely expressed. This research comes to know the extent of interest of the university press in various student issues.
In order to identify the problem of the research, the method of content analysis was adopted within the survey method
... Show MoreLong-term organic amendments are a key strategy to build soil organic carbon (SOC) stocks in semiarid agroecosystems, where low biomass inputs and calcareous parent material constrain carbon accumulation. This 14-year field experiment in central Iraq (2000–2014) evaluated how a gradient of organic matter (OM) additions (0, 1, 2.5, 5, 10, and 20%) affects SOC dynamics, nutrient availability, and soil organic matter composition in clay-dominated, semiarid soils. Surface and subsurface samples (0–30, 30–60, and 60–90 cm) were analysed for SOC, nutrients, and mid-infrared Fourier transform infrared (FTIR) spectra, which were then integrated with Partial Least Squares (PLS) regression and RothC simulations. Moderate OM inputs (5
... Show MoreAbsorption, fluorescence, quantum yield and lifetime of rhodamine 6G in chloroform, methanol and dimethyl sulfoxide were measured. From a comparison of these quantities, with those for solid solutions (solid solutions are obtained by mixing constant volume proportions of dye at a concentration of 1*10-4M/l with different volume proportions from the concentrated solution of polymer in chloroform and dimethyl sulfoxide). The results showed that the addition of polymer to liquid concentrated solutions (1*10-4M/l )of rhodamine 6G dye from expecting [which leading to development active medium for laser dye at high concentration] increase the spectra shift toward high energies, and the luminescence quantum yield but decreasing radiative lifetim
... Show MoreSUMMARY. – Absorption, flourescence, quantum yield and lifetime of rhodamine B in chloroform, methanol and dimethyl sulfoxide were measured. A comparison was done of these quantities with those for solid solutions, which are obtained by mixing constant volume proportions of dye at a concentration of 1×10–4M/l with different volume proportions from the concentrated solution of polymer in chloroform and dimethyl sulfoxide. The results showed that the addition of polymer to liquid concentrated solutions (1×10–4M/l) of rhodamine B dye from expecting, which leads to development of active medium for laser dye at high concentration, increase the spectra shift toward high energies, and the luminescence quantum yield but decreasing radiative
... Show MoreExperiments were conducted to study axial liquid dispersion coefficient in slurry bubble column of 0.15 m inside diameter and 1.6 m height using perforated plate gas distributor of 54 holes of a size equal to 1 mm diameter and with a 0.24 free area of holes to the cross sectional area of the column. The three phase system consists of air, water and PVC used as the solid phase. The effect of solid loading (0, 30 and 60 kg/m3) and solid diameter (0.7, 1.5 and 3 mm) on the axial liquid dispersion coefficient at different axial location (25, 50 and 75 cm) and superficial gas velocity covered homogeneous-heterogeneous flow regime (1-10 cm/s) were studied in the present work. The results show that the axial liquid dispersion coeffic
... Show More