Preferred Language
Articles
/
bijps-599
Micro encapsulation of Naproxen By Complex Coacervation and Aqueous Colloid Dispersion Part ( 1 )
...Show More Authors

Naproxen is a non steroidal anti inflammatory and antipyretic drug which has local irritation effect  on  the  stomach, and  unpleasant taste,  besides bad   flowability and light sensitivity .The drug was prepared as microcapsules by complex coacervation method using acacia-gelatin coating materials , and aqueous colloid polymer dispersion method ( ACPD ), using ethyl cellulose and sodium alginate coating materials . The results indicated that microcapsules prepared by 2:1  core:wall ratio is the best for both methods, with an average encapsulation efficiency (75%) and avarege yield (90%) .

Moreover the drug release was affected mainly by core : ratio ,pH enviroment and method of microencapsulation .

Key words: Naproxen,Microcapsule , Aqueaus colloid polymer dispersion

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Jun 05 2023
Journal Name
Al-khwarizmi Engineering Journal
Removal of Malachite Green from Aqueous Solution using Ficus Benjamina Activated Carbon-Nonmetal Oxide synthesized by pyro Carbonic Acid Microwave
...Show More Authors

Activated carbon derived from Ficus Binjamina agro-waste synthesized by pyro carbonic acid microwave method and treated with silicon oxide (SiO2) was used to enhance the adsorption capability of the malachite green (MG) dye. Three factors of concentration of dye, time of mixing, and the amount of activated carbon with four levels were used to investigate their effect on the MG removal efficiency. The results show that 0.4 g/L dosage, 80 mg/L dye concentration, and 40 min adsorption duration were found as an optimum conditions for 99.13% removal efficiency. The results also reveal that Freundlich isotherm and the pseudo-second-order kinetic models were the best models to describe the equilibrium adsorption data.

 

View Publication Preview PDF
Scopus (6)
Crossref (3)
Scopus Crossref
Publication Date
Mon Oct 17 2016
Journal Name
Gstf Journal Of Advances In Medical Research (jamr)
An investigation into the factors governing the degree of dissolution enhancement of solid dispersion for poorly soluble drugs
...Show More Authors

Solid dispersion (SD) formulation has attracted much attention due to its potential in enhancing dissolution performances of poorly soluble active pharmaceutical ingredients (API). Recently, a review on dissolution performances of SDs classifies the improvement into 3 categories, where 82 % of the studies showed improved bioavailability, 8 % showed reduced bioavailability and 10 % revealed similar bioavailability as compared to pure APIs. This indicates the inconsistent degrees of dissolution improvement of poorly soluble APIs in SD. Although a few factors related to the choice of carriers have been suggested to contribute to the dissolution improvement, however, the underlying factor determining the discrepancy in the degree of dissolution

... Show More
Publication Date
Sat Jul 23 2022
Journal Name
Environmental Monitoring And Assessment
Impact of using magnetic water on the micro structure of leached saline-sodic soil
...Show More Authors

View Publication
Scopus (4)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Thu Nov 08 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
The effect of mouth rinses on surface micro hardness of two esthetic restorative materials
...Show More Authors

Objective: To evaluate the effect of mouth rinses (Biofresh and ZAK) on the surface micro hardness
of two light cure restorative material (Tetric ceram ivoclar-vivadent) and (3M Z 250) dental
composite.
Methodology: The microhardness values of (sixty) composite specimens were measured at the top
surfaces after 24 hours of immersion in different solutions (Biofresh, Zak mouth wash and distilled
water as control). Comparison done using descriptive statistics (mean, SD, SEM, minimum and
maximum values) and inferential statistics (ANOVA and LSD) test.
Results: The biofresh mouth rinse which has high alcohol containing has less effect on
microhardness of tetric ceram than the zak &distiled water , while the effect

... Show More
View Publication Preview PDF
Publication Date
Sat Jun 01 2024
Journal Name
Case Studies In Chemical And Environmental Engineering
Congo red removal from aqueous solution by electrocoagulation- electro-oxidation combined system with Al and Cu–Mn–Ni nano composite as efficient electrodes
...Show More Authors

Removing Congo red (CR) is critical in wastewater treatment. We introduce a combination of electrocoagulation (EC) and electro-oxidation (EO) to address the elimination of CR. We also discuss the deposition of triple oxides (Cu–Mn–Ni) simultaneously on both anodic and cathodic graphite electrodes at constant current density. These electrodes efficiently worked as anodes in the EC-EO system. The EC-CO combination eliminated around 98 % of the CR dye and about 95 % of the Chemical Oxygen demand (COD), and similar results were obtained with the absence of NaCl. Thus, EC-EO is a promising technique to remove CR in an environmentally friendly pathway.

View Publication
Scopus (8)
Crossref (5)
Scopus Crossref
Publication Date
Thu Jan 30 2020
Journal Name
Telecommunication Systems
Nature-inspired optimization algorithms for community detection in complex networks: a review and future trends
...Show More Authors

View Publication
Scopus (30)
Crossref (26)
Scopus Clarivate Crossref
Publication Date
Fri Jul 19 2024
Journal Name
Baghdad Science Journal
The correlation between micro-RNA 146a and IL-17 in the serum of Iraqi patients with cystic echinococcosis
...Show More Authors

داء المشوكات الكيسي (CE) هو مرض وبائي يسبب مرضًا خطيرًا وخسائر اقتصادية في معظم بلدان العالم. MiRNAs هي عامل جيني ضروري لتنظيم الاستجابة المناعية من خلال قدرته على التدخل في التعبير الخلوي ؛ واحد هذه الحوامض النووية الدقيقة -146 أ. هدفت الدراسة الحالية تقييم إذا كان بإمكاننا استخدام microRNA 146a كمؤشر حيوي للكشف عن    CEو تحديد العلاقة بين التعبير الجيني microRNA 146a و IL-17 في مرضى CE.حيث اشتملت الدراسة على 50 مريضًا من CE تم إد

... Show More
View Publication
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Fri Dec 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of Polyamide (Nylon 6) Micro-Particles Incorporation into RTV Maxillofacial Silicone Elastomer on Tear and Tensile Strength
...Show More Authors

Background: The longevity of any prosthesis depends on the materials from which it was fabricated, that is why, defects in the material properties may reduce the service life of prosthesis and necessitate its replacement. The aim of this study was to evaluate the effect of adding different concentrations of Polyamide-6 (Nylon-6) on the tear and tensile strength of A-2186 RTV silicone elastomer. Materials and Methods: 80 samples were fabricated by the addition of 0%, 1%, 3% and 5% by weight PA-6 micro-particles powder to A-2186 platinum RTV silicone elastomer. The study samples were divided into four (4) groups, each group containing 20 samples. One control group was prepared without PA-6 micro particles and three experimental groups were pr

... Show More
View Publication Preview PDF
Crossref (10)
Crossref
Publication Date
Fri Dec 01 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of Polyamide (Nylon 6) Micro-Particles Incorporation into RTV Maxillofacial Silicone Elastomer on Tear and Tensile Strength
...Show More Authors

View Publication
Crossref (10)
Crossref
Publication Date
Thu Jan 08 2015
Journal Name
Chemical And Process Engineering Research
Uni and Simplex Optimization for the Spectrophotometric Determination of Erythromycin ethylsuccinate Drug via Charge-Transfer Complex Formation
...Show More Authors

Charge transfer complex formation method has been applied for the spectrophotometric determination of erythromycin ethylsuccinate, in bulk sample and dosage form. The method was accurate, simple, rapid, inexpensive and sensitive depending on the formed charge- transfer complex between cited drug and, 2,3- Dichloro-5,6-dicyano-p- benzoquinone (DDQ) as a chromogenic reagent. The formed complex shows absorbance maxima at 587 nm against reagent blank. The calibration graph is linear in the ranges of (10 - 110) μg.mL-1 with detection limit of 0.351μg.mL-1. The results show the absence of interferences from the excipients on the determination of the drug. Therefore the proposed method has been successfully applied for the determination of eryth

... Show More
Preview PDF