Preferred Language
Articles
/
bijps-563
Cephalothin as a Carrier of 6-Mercaptopurine for Targeting Cancer Tissues
...Show More Authors

A lower extracellular pH is one of the few well-documented physiological differences between tumour and normal tissues. On the other hand, elevated glutathione (GSH) level has been detected in many tumours compared with healthy surrounding tissues. The compound II: 3-(9H-purin-6-yl-thio) carbonothionyl methyl-8-oxo-7-(2-thiophen-2-yl) acetamido-5-thia-1-azabicyclo-4-octo-ene-carboxylic acid was a cephalothin derivative contain 6-mercaptopurine (6-MP). Compound II react with general base catalysis in slightly acidic pH or with sulfhydryl nucleophiles to release the chemotherapeutic drug 6-MP. The generation of compound II was accomplished following multistep reaction procedures. The structure of compound II and its intermediate was confirmed by their melting point, infrared spectroscopy, CHN and NMR analysis. The hydrolysis of compound II in aqueous buffer solution of pH 6 and in the presence of GSH at pH 7.4 was studied. The partition coefficient (PC) of compound II was also determined. Compound II has acceptable rate of hydrolysis at slightly acidic medium pH 6 (t1/2 = 56.34 min.) and 80% of compound II had been converted to 6-MP within 30 min in the presence of GSH. And the compound has acceptable stability at pH 7.4(t0.5=639.65 min.) and the rate of hydrolysis was effected by change the buffer concentration.  This compound can selectively deliver 6-MP into the tumour tissues which have acidic pH or elevated GSH level. Compound II had an improved PC value of 12.23 compared to 1.22 for free drug 6-MP confirming higher lipophilicity.

Key words: 6-mercaptopurine, cancer, prodrug, targeting

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Apr 12 2024
Journal Name
Revista Latinoamericana De Hipertension
Most common risk factors distribution for cervical cancer
...Show More Authors

Scopus
Publication Date
Mon May 27 2024
Journal Name
Pakistan Journal Of Criminology
The Liability of Maritime Carrier under the Iraqi Transport Law and International Conventions
...Show More Authors

Everywhere carriers incur a measure of liability for the safety of the goods. Carriers are liable for any damage or for the loss of the goods that are in their possession as carriers unless they prove that the damage or loss is attributable to certain excepted causes. Damaged and lost items can unfortunately be a common problem when shipping freight. Legal responsibilities arise due to loss or damage during transit while cargo is in their care. This study intends to investigate the nature of the liability of the maritime carrier when this liability is realized, and the extent to which it can be paid or disposed of given the risks realized from the transportation process, which may result in damage or loss of the goods, and the damag

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Sun Dec 01 2002
Journal Name
Iraqi Journal Of Physics
Dependence of the Hall Mobility and Carrier Concentration on Thickness and Annealing Temperature
...Show More Authors

Hall effect measurements have been made on a-As2Te3 thin films different thickness film in the range (200-350) nm. The Hall mobility in a-As2Te3 thin films decreases with increasing annealing temperature but the carrier concentration increases. When increasing the film thickness increases the Hall mobility decreases, while the carrier concentration increases.

View Publication Preview PDF
Publication Date
Sun Dec 09 2018
Journal Name
Baghdad Science Journal
Detection of Pseudomonas aeruginosa in Clinical Samples Using PCR Targeting ETA and gyrB Genes
...Show More Authors

Pseudomonas aeruginosa has variety of virulence factors that contribute to its pathogenicity. Therefore, rapid detection with high accuracy and specificity is very important in the control of this pathogenic bacterium. To evaluate the accuracy and specificity of Polymerase Chain Reaction (PCR) assay, ETA and gyrB genes were targeted to detect pathogenic strains of P. aeruginosa. Seventy swab samples were taken from patients with infected wounds and burns in two hospitals in Erbil and Koya cities in Iraq. The isolates were traditionally identified using phenotypic methods, and DNA was extracted from the positive samples, to apply PCR using the species specific primers targeting ETA, the gene encoding for exotoxin A, and gyrB gene. The res

... Show More
View Publication Preview PDF
Scopus (5)
Scopus Clarivate Crossref
Publication Date
Tue Jan 08 2019
Journal Name
Iraqi Journal Of Physics
Calculation of the total mass stopping power for electrons in some human body tissues in the energy range 0.01-1000 MeV
...Show More Authors

The mass collision energy loss (dE/dX), the mass radiative energy loss (Srad/) and the total mass stopping power of electrons in the energy range of 0.01 MeV up to 1000 MeV has been calculated for Lung, Urea and Skin. The results of the present work for the mass collision stopping power of electrons in Lung, Urea and Skin are in excellent agreement with the standard results given by ESTAR program, where the maximum percentage error between the present calculated values and that of ESTAR program in Lung tissue, Urea and Skin tissue is 0.27%, 0.3% and 0.8% respectively. The mass radiative energy loss of electrons in the same energy range is also calculated using a modified equation, and the results are found to be in very good agreem

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Feb 01 2023
Journal Name
Baghdad Science Journal
Potential Role of 8-Hydroxyguanosine and some Pro Inflammatory Cytokines as Biomarkers in Colorectal Cancer Iraqi Patients
...Show More Authors

8-hydroxyguanosine (8-OHdG) is considered as an indicator of the oxidative stress. Pro inflammatory cytokines are critical parts of the pathophysiological processes to which treatment can be applied. The aim of this study was to evaluate 8-OHdG and pro inflammatory cytokines concentration in colon carcinoma patients. Blood samples were taken before treatment from 50 incident cases with colon cancer (stage III) admitted for health examination at the Nanakali Hospital in Erbil city with 45 healthy samples of controls with age range between 38-69 years for both groups. All studied parameters were estimated by ELISA. Participants at this study were 95 Participants ranged in age from 38 to 69 years, 50 Participants had been newly diagnosed wi

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sun Jul 20 2025
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Using a 3D Chaotic Dynamic System as a Random Key Generator for Image Steganography
...Show More Authors

In today's digital era, the importance of securing information has reached critical levels. Steganography is one of the methods used for this purpose by hiding sensitive data within other files. This study introduces an approach utilizing a chaotic dynamic system as a random key generator, governing both the selection of hiding locations within an image and the amount of data concealed in each location. The security of the steganography approach is considerably improved by using this random procedure. A 3D dynamic system with nine parameters influencing its behavior was carefully chosen. For each parameter, suitable interval values were determined to guarantee the system's chaotic behavior. Analysis of chaotic performance is given using the

... Show More
View Publication Preview PDF
Publication Date
Thu Jun 28 2018
Journal Name
Iraqi Journal Of Physics
Measurement of Percentage Depth Dose (PDD) for 6 MeV in water phantom and homogenous actual planning
...Show More Authors

Radiotherapy is the branch of clinical medicine concerned with the application of ionizing radiation in the treatment of disease. And it is used to killing of cancer cells in a tissue using ionizing radiation while keeping the sparing of healthy cells at acceptable level. X-ray beams are used to deposit absorbed dose at depth within a patient at the site of the tumor. The aim of this work is studying the relationship between the depth dose and the field size in water phantom and homogenous actual planning. In our work, the dose distribution at different depths (zero-18 cm) deep at1cm interval treated with field size (10×10 and 20×20) cm2 were studied. Results show that high similarity between water phantom and actual planning for

... Show More
Publication Date
Thu Nov 14 2024
Journal Name
Journal Of Studies And Researches Of Sport Education
The Effect Of Suggested Exercises On Developing Some Mental Abilities For Children Aged 4-6 Years
...Show More Authors

The purpose of the current article lies in determining  the impact of the suggestive  exercises on the development of  the mental capabilities of children. The researchers used the experimental method with a single-group design, which was appropriate for the core of the current article . The study samble  has been specified as children aged 4-6 years in Umm Al-Rabi'een Kindergarten, with a total of 95 children. The study samble  (15 children) was randomly selected.  . After the exercises were completed, the post-tests have been carried out  on the sample  with similar circumstances as that of  pre-tests.  Researchers used statistical methods in the SPSS program. After the results were presented, analyzed, and discussed, The resear

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Sep 11 2018
Journal Name
Iraqi Journal Of Physics
Measurement of Percentage Depth Dose (PDD) for 6 MeV in water phantom and homogenous actual planning
...Show More Authors

Radiotherapy is the branch of clinical medicine concerned with the application of ionizing radiation in the treatment of disease. And it is used to killing of cancer cells in a tissue using ionizing radiation while keeping the sparing of healthy cells at acceptable level. X-ray beams are used to deposit absorbed dose at depth within a patient at the site of the tumor. The aim of this work is studying the relationship between the depth dose and the field size in water phantom and homogenous actual planning. In our work, the dose distribution at different depths (zero-18 cm) deep at1cm interval treated with field size (10×10 and 20×20) cm2 were studied.
Results show that high similarity between water phantom and actual planning for th

... Show More
View Publication Preview PDF
Crossref