Preferred Language
Articles
/
bijps-503
Validity of Generalized Standard Addition Method for a Mixture of Amino Acid Analysis
...Show More Authors

A Modified version of the Generlized standard addition method ( GSAM) was developed. This modified version was used for the quantitative determination of arginine   (Arg) and glycine ( Gly) in arginine  acetyl salicylate – glycine complex . According to this method two linear equations were solved to obtain the amounts of (Arg) and (Gly). The first equation was obtained by spectrophotometic measurement of the total absorbance of (Arg) and (Gly) colored complex with ninhydrin . The second equation was obtained by measuring the total acid consumed by total amino groups of (Arg) and ( Gly). The titration was carried out in non- aqueous media using perchloric acid in glacial acetic acid as a titrant. The developed method is accurate, precise, and free from interferences and may provide a useful approach to calibrate in the direct analysis of solid sample and it is suitable method to be used as a quality control procedure.

Key words: GSAM , amino acid analysis

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Nov 01 2015
Journal Name
Journal Of Craniofacial Surgery
Evaluation of the Trephine Method in Harvesting Bone Graft From the Anterior Iliac Crest for Oral and Maxillofacial Reconstructive Surgery
...Show More Authors

View Publication
Scopus (16)
Crossref (16)
Scopus Clarivate Crossref
Publication Date
Sun Jun 30 2013
Journal Name
Al-kindy College Medical Journal
Rapid and Reliable Method for Identification of V. Cholera O1 and V. Cholera O139 Serotypes in Diarrheal Cases in Baghdad.
...Show More Authors

Backgrround:: Cholera is gastroenteritis caused by enterotoxin producing Vibrio cholera. Cholera is predominantly a waterborne disease especially in countries with inadequate sanitation. Several rapid methods have been developed and used to detect V. cholerae serotypes directly from stools.
Objjecttiives:: to evaluate a rapid and accurate method for the diagnosis of cholera caused by V. cholerae O1 and O139 serogroups d to find the incidence of sporadic cases of cholera in Baghdad.
Metthods:: Sixty four stool samples were collected from four hospitals in Baghdad. The age of patients ranging from two months to 12 years, 26 were females and 38 males. Immunochromatographic visual test for qualitative detection of O1 and /or O139 serog

... Show More
View Publication Preview PDF
Publication Date
Tue Nov 01 2022
Journal Name
Res Militaris
The Impact of the different methods of Selecting One Group in Calculating the Items Sensitivity Coefficient on the Standard Characteristics of the Criterion-Referenced Test
...Show More Authors

AbstractThe research aims to identify the impact of the different methods in calculating the Items sensitivity coefficient on the standard characteristics of the Criterion-Referenced test in the measurement and evaluation material. The research sample consisted of (35) male and female students, who were chosen by the intentional method. The researcher prepared learning-teaching program in constructing the content of the measurement and evaluation material for non-specialized departments, prepared an achievement test in its equivalent forms, identified the results of agreement between the methods used in analyzing the items of the criterion-referenced test, and compared the standard characteristics of the achievement test, both according to

... Show More
Preview PDF
Publication Date
Wed May 24 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Science
Direct and Indirect Spectrophotometric Determination of Paracetamol in Pharmaceutical Preparations By Oxidative Coupling With p-Amino-2-hydroxy Sodium Benzoate
...Show More Authors

New simple and sensitive spectrophotometric methods for the determination of paracetamol in aqueous medium were developed. The first method is based on coupling of paracetamol with p-amino-2-hydroxy sodium benzoate (AHB) in the presence of sodium periodate, as oxidizing agent, to form a brownish-orange compound which shows a λmax at 470 nm. The molar absorptivity (εmax) of the colored product was found to be (3371) l. mole1. cm-1 and Sandel’s index 0.0449 μg. cm-2. The method follows Beer’s law in the concentration range of 12.5-500.0 μg of paracetamol in a final volume of 25 ml (0.5-20.0) μg. ml-1 with relative standard deviation percent (RSD%) ranged between 0.26-4.71% and accuracy, expressed by recovery percent, 95-106% for five

... Show More
Publication Date
Fri Dec 19 2014
Journal Name
Al-mustansiriyah
Synthesis, Spectroscopic and Antibacterial Studies of N (2-amino phenyl)-N-((pyridine-2-yl) methyl) Benzene-1, 2-Diamine Complexes
...Show More Authors

Publication Date
Thu Oct 25 2018
Journal Name
Al-nahrain Journal Of Science
Synthesis of some New 3-Substituted Heterocyclic Compounds Containing Bridgehead Nitrogen from 2-Amino Pyridine with Study Their Biological Activity
...Show More Authors

View Publication
Crossref
Publication Date
Sat Jun 01 2024
Journal Name
Minar International Journal Of Applied Sciences And Technology
PREPARATION, CHARACTERIZATION AND EVALUATE THEIR BIOLOGICAL ACTIVITY OF NEW HETEROCYCLIC COMPOUNDS DERIVED FROM 4-((1-(4-HYDROXYPHENYL) ETHYLIDENE) AMINO) BENZENESULFONAMIDE
...Show More Authors

The research included the preparation of cyclic compounds from thiazoles, imidazoles and oxazepines from the reaction of cyclization starting material that acts Schiff bases, which is a raw material in the formation of cyclic compounds from Schiff's(B1) by reaction of 4- aminobenzenesulfonylamide with 4-hydroxyacetophenone which can used to synthesized two lines. The first introducing the preparation of pyrazoles [B4, B5] from ester [B2], which derived to acid hydrazide[B3] with hydrazine hydrate and final pyrazoles obtained by the reaction with diethylmalonate and acetylacetone. The second including prepared the new 1,3-oxazepine1,5-dione derivatives[B6,B7,B8] from adding different anhydrides to the base[B1] as a seven membered ring ; te

... Show More
View Publication
Crossref
Publication Date
Fri Oct 01 2010
Journal Name
Analytica Chimica Acta
A reversed phase high performance liquid chromatography method for the determination of fumonisins B1 and B2 in food and feed using monolithic column and positive confirmation by liquid chromatography/tandem mass spectrometry
...Show More Authors

The development of a reversed phase high performance liquid chromatography fluorescence method for the determination of the mycotoxins fumonisin B1 and fumonisin B2 by using silica-based monolithic column is described. The samples were first extracted using acetonitrile:water (50:50, v/v) and purified by using a C18 solid phase extraction-based clean-up column. Then, pre-column derivatization for the analyte using ortho-phthaldialdehyde in the presence of 2-mercaptoethanol was carried out. The developed method involved optimization of mobile phase composition using methanol and phosphate buffer, injection volume, temperature and flow rate. The liquid chromatographic separation was performed using a reversed phase Chromolith® RP-18e column

... Show More
View Publication
Scopus (33)
Crossref (32)
Scopus Clarivate Crossref
Publication Date
Thu May 30 2024
Journal Name
Iraqi Journal Of Science
Bifurcation and Stability Analysis of Stagnation Point for Fluid Flow in an Inclined Channel with Inclined Magnetic Field for Peristaltic Transport
...Show More Authors

Streamlined peristaltic transport patterns, bifurcations of equilibrium points, and effects of an inclined magnetic field and channel are shown in this study. The incompressible fluid has been the subject of the model's investigation. The Reynolds values for evanescence and an infinite wavelength are used to constrain the flow while it is being studied in a slanted channel with a slanted magnetic field. The topologies over their domestic and cosmopolitan bifurcations are investigated for the outcomes, and notion of the dynamical system are employed. The Mathematica software is used to solve the nonlinear autonomous system. The flow is found to have three different flow distributions namely augmented, trapping and backward flow. Outc

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Wed Jul 17 2019
Journal Name
Aip Conference Proceedings
The correction of the line profiles for x-ray diffraction peaks by using three analysis methods
...Show More Authors

In this study used three methods such as Williamson-hall, size-strain Plot, and Halder-Wagner to analysis x-ray diffraction lines to determine the crystallite size and the lattice strain of the nickel oxide nanoparticles and then compare the results of these methods with two other methods. The results were calculated for each of these methods to the crystallite size are (0.42554) nm, (1.04462) nm, and (3.60880) nm, and lattice strain are (0.56603), (1.11978), and (0.64606) respectively were compared with the result of Scherrer method (0.29598) nm,(0.34245),and the Modified Scherrer (0.97497). The difference in calculated results Observed for each of these methods in this study.

View Publication
Scopus (14)
Crossref (12)
Scopus Clarivate Crossref