Preferred Language
Articles
/
bijps-425
Response Surface Methodology for Development and Optimization of Theophylline Pulmonary Delivery System
...Show More Authors

The aim of the present study was to develop theophylline (TP) inhalable sustained delivery system by preparing solid lipid microparticles using glyceryl behenate (GB) and poloxamer 188 (PX) as a lipid carrier and a surfactant respectively. The method involves loading TP nanoparticles into the lipid using high shear homogenization – ultrasonication technique followed by lyophilization. The compositional variations and interactions were evaluated using response surface methodology, a Box – Behnken design of experiment (DOE). The DOE constructed using TP (X1), GB (X2) and PX (X3) levels as independent factors. Responses measured were the entrapment efficiency (% EE) (Y1), mass median aerodynamic diameter (MMAD, daer) (Y2), zeta potential (ZP, ξ) (Y3), fine particles fraction (% FPF) (Y4) and percentage of dissolution efficiency at 420 minutes (% DE420) (Y5). The optimized formula was characterized by differential scanning calorimetry (DSC), Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM) and X – ray powder diffraction (XRD) demonstrated that prolonged release physically due to the loaded TP exists mostly in its crystalline state . Analysis of dissolution data of the optimized formula indicated that the best fitting is with Higuchi model, whereas the mechanism of drug release pattern follows anomalous or non – Fickian diffusion.

Key words: Glyceryl behenate, solid lipid microparticles, theophylline nanoparticles

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jan 13 2019
Journal Name
Iraqi Journal Of Physics
Spectroscopic study for plasma parameters in co-sputtering system
...Show More Authors

In this work the parameters of plasma (electron temperature Te,
electron density ne, electron velocity and ion velocity) have been
studied by using the spectrometer that collect the spectrum of
plasma. Two cathodes were used (Si:Si) P-type and deposited on
glass. In this research argon gas has been used at various values of
pressures (0.5, 0.4, 0.3, and 0.2 torr) with constant deposition time
4 hrs. The results of electron temperature were (31596.19, 31099.77,
26020.14 and 25372.64) kelvin, and electron density (7.60*1016,
8.16*1016, 6.82*1016 and 7.11*1016) m-3. Optical properties of Si
were determined through the optical transmission method using
ultraviolet visible spectrophotometer with in the range
(

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Dec 01 2017
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
Proposed Audit Program for Automated Clearing House System (ACH)
...Show More Authors

إن استخدام النظم الالكترونية في القطاع المصرفي وبالخصوص نظام مقاصة الصكوك الالكترونية (ACH) في عمليات التحويل الالكتروني للاموال بين المصارف تتضمن تحويلات مالية عالية القيمة  بين  المصارف المشاركة بهذا النظام, وان اي خلل قد يحدث بالنظام يؤدي الى حالات تلاعب في مقاصة الصكوك الالكترونية في المصارف المشاركة وبالتالي حدوث عملية اختلاس, ومن هذا المنطلق تبرز مشكلة البحث في اهمية توافر برنامج تدقيق مقترح ياخ

... Show More
View Publication
Crossref
Publication Date
Wed Feb 29 2012
Journal Name
Al-khwarizmi Engineering Journal
Design a Fault Tolerance for Real Time Distributed System
...Show More Authors

This paper designed a fault tolerance for soft real time distributed system (FTRTDS). This system is designed to be independently on specific mechanisms and facilities of the underlying real time distributed system. It is designed to be distributed on all the computers in the distributed system and controlled by a central unit.

Besides gathering information about a target program spontaneously, it provides information about the target operating system and the target hardware in order to diagnose the fault before occurring, so it can handle the situation before it comes on. And it provides a distributed system with the reactive capability of reconfiguring and reinitializing after the occurrence of a failure.

View Publication Preview PDF
Publication Date
Mon Dec 03 2018
Journal Name
Journal Of Engineering
Variable Structure Control Design for a Magnetic Levitation System
...Show More Authors

In this paper the variable structure control theory is utilized to derive a discontinuous controller to the magnetic levitation system. The magnetic levitation system model is considered uncertain, which subjected to the uncertainty in system parameters, also it is open-loop unstable and strongly nonlinear. The proposed variable structure control to magnetic levitation system is proved, and the area of attraction is determined. Additionally, the chattering, which induced due to the discontinuity in control law, is attenuated by using a non-smooth approximate. With this approximation the resulted controller is a continuous variable structure controller with a determined steady state error according to the selected control

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Mar 31 2017
Journal Name
Journal Of Engineering
Rotating Ceramic Water Filter Discs System for Water Filtration
...Show More Authors

This work aimed to design, construct and operate a new laboratory scale water filtration system. This system was used to examine the efficiency of two ceramic filter discs as a medium for water filtration. These filters were made from two different ceramic mixtures of local red clay, sawdust, and water.  The filtration system was designed with two rotating interfered modules of these filters.  Rotating these modules generates shear force between water and the surfaces of filter discs of the filtration modules that works to reduce thickness of layer of rejected materials on the filters surfaces. Each module consists of seven filtration units and each unit consists of two ceramic filter discs.    The average measured hy

... Show More
View Publication Preview PDF
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Nano Fluid Detection for HPHE System Using Different Lasers
...Show More Authors

Among the different passive techniques heat pipe heat exchanger (HPHE) seems to be the most effective one for energy saving in heating ventilation and air conditioning system (HVAC). The applications for nanofluids with high conductivity are favorable to increase the thermal performance in HPHE. Even though the nanofluid has the higher heat conduction coefficient that dispels more heat theoretically but the higher concentration will make clustering .Clustering is a problem that must be solved before nanofluids can be considered for long-term practical uses. Results showed that the maximum value of relative power is 0.13 mW at nanofluid compared with other concentrations due to the low density of nanofluid at this concentration. For highe

... Show More
View Publication Preview PDF
Publication Date
Tue Feb 27 2018
Journal Name
Pharmaceutics
Ocular Drug Delivery Barriers—Role of Nanocarriers in the Treatment of Anterior Segment Ocular Diseases
...Show More Authors

Ocular drug delivery is challenging due to the presence of anatomical and physiological barriers. These barriers can affect drug entry into the eye following multiple routes of administration (e.g., topical, systemic, and injectable). Topical administration in the form of eye drops is preferred for treating anterior segment diseases, as it is convenient and provides local delivery of drugs. Major concerns with topical delivery include poor drug absorption and low bioavailability. To improve the bioavailability of topically administered drugs, novel drug delivery systems are being investigated. Nanocarrier delivery systems demonstrate enhanced drug permeation and prolonged drug release. This review provides an overview of ocular barr

... Show More
View Publication
Scopus (328)
Crossref (317)
Scopus Clarivate Crossref
Publication Date
Sat Jun 30 2007
Journal Name
Al-kindy College Medical Journal
Perinatal out come of Breech Presentation in the Presentation in the Pretext Mode of Delivery
...Show More Authors

Objectives: To choose the best mode of delivery
for term, frank or complete, breech presentation
through studying the perinatal outcome of each mode of
delivery decided when managing a group of pregnant
ladies presented with breech delivery in our centre.
Methods: One hundred and fifty pregnant ladies
presented at term with singleton, frank or complete,
breech presentation for delivery in our centre during the
period from May 2004 toAugust 2005.
Mode of delivery, parity, gestational age, maternal age,
maternal medical illness, and birth weight where the
variables that have been tested in each delivery
included in the study to verify their relationship to
perinatal outcome.
Results: No significant

... Show More
View Publication Preview PDF
Publication Date
Mon Sep 01 2014
Journal Name
Engineering And Technology Journal
Analysis of the Capacity, Spectral Efficiency and Probability of Outage of Adaptive Mobile Channel for WiMAX System
...Show More Authors

Preview PDF
Publication Date
Sun Apr 08 2018
Journal Name
Al-khwarizmi Engineering Journal
Design of Hybrid Neural Fuzzy Controller for Human Robotic Leg System
...Show More Authors

 In this paper, the human robotic leg which can be represented mathematically by single input-single output (SISO) nonlinear differential model with one degree of freedom, is analyzed and then a simple hybrid neural fuzzy controller is designed to improve the performance of this human robotic leg model. This controller consists from SISO fuzzy proportional derivative (FPD) controller with nine rules summing with single node neural integral derivative (NID) controller with nonlinear function. The Matlab simulation results for nonlinear robotic leg model with the suggested controller showed that the efficiency of this controller when compared with the results of the leg model that is controlled by PI+2D, PD+NID, and F

... Show More
View Publication Preview PDF
Crossref