Preferred Language
Articles
/
bijps-411
Neutrophil / Lymphocyte Ratio is not Correlated with Disease Activity in Rheumatoid Arthritis Patients
...Show More Authors

Rheumatoid arthritis is a chronic systemic inflammatory disease. Inflammation leads to joint damage and increases the risk of cardiovascular diseases. Neutrophil lymphocyte ratio (NLR) is a measure of inflammation in many diseases. Therefore, we aimed to evaluate the usefulness of NLR to detect inflammation in RA, and its correlation to RA disease activity indices and some hematological parameters. A cross-sectional study involving 24 patients with active rheumatoid arthritis (RA) who are using MTX participated in this study. All patients were clinically evaluated using disease activity score of 28 joints (DAS28) and simplified disease activity index (SDAI), whereas functional disability was assessed by health assessment questionnaire disability index (HAQDI); Moreover, blood specimen of each patient was used for measuring erythrocyte sedimentation rate (ESR), C – reactive protein (CRP), rheumatoid factor (RF), hemoglobin (Hb), white blood cells (WBC) count, platelets and red blood cells (RBCs) count, and NLR ratio.NLR was positively correlated with ESR and inversely correlated with Hb, but it didn’t show any correlation with other clinical and laboratory parameters. In conclusion NLR is less correlated with inflammation and not suitable to monitor disease activity in RA patients using MTX.

Keywords: Rheumatoid arthritis, Inflammation, Neutrophil lymphocyte ratio.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Nov 01 2016
Journal Name
Journal Of Engineering
Energy and Exergy Analyses of Heat Pump Cycle with Refrigerant Injection Technology
...Show More Authors

The effect of refrigerant injection techniques on the performance of heat pump system based on exergy analysis was studied theoretically. Three refrigerant injection techniques were used; the first was achieved by injected vapour in volume ratios from 1 to 7% in the accumulator. The second was injection liquid refrigerant in the discharge line with the aid of Liquid Pressure Amplification (LPA) pump, with volume ratios from 1 to 10%. The third was a hybrid injection with volume ratios of injected vapour and liquid varied from 1 to 3% and 1 to 10%; respectively. The following improvements in cycle performance were observed. For vapour injection technique, the best ratio of injection was 5%, the exergy destruction reduced

... Show More
View Publication Preview PDF
Publication Date
Thu Dec 15 2022
Journal Name
Al-academy
Printmaking Techniques to Enable People with Visual Impairment to Taste Print Artworks
...Show More Authors

The study aims to integrate the visually impaired people into the art connoisseur community through producing special print artworks to enable the visually impaired people to use their other senses to feel artworks by using artistic printing techniques through adding some prominent materials to the printing colors or making an impact that visually impaired people can perceive using their other senses. This study also aims to set up art exhibitions that display tangible works that can enable visually impaired people to feel artwork and understand its elements to enable them to feel it through other senses.
The study follows the experimental method, through using artistic printing techniques, which allow printing with prominent textur

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jan 14 2018
Journal Name
Journal Of Engineering
Regression Modeling of EDM Process for AISI D2 Tool Steel with RSM
...Show More Authors

In this paper, Response Surface Method (RSM) is utilized to carry out an investigation of the impact of input parameters: electrode type (E.T.) [Gr, Cu and CuW], pulse duration of current (Ip), pulse duration on time (Ton), and pulse duration off time (Toff) on the surface finish in EDM operation. To approximate and concentrate the suggested second- order regression model is generally accepted for Surface Roughness Ra, a Central Composite Design (CCD) is utilized for evaluating the model constant coefficients of the input parameters on Surface Roughness (Ra). Examinations were performed on AISI D2 tool steel. The important coefficients are gotten by achieving successfully an Analysis of V

... Show More
View Publication Preview PDF
Publication Date
Wed Sep 29 2010
Journal Name
Biotechnology Letters
Streptomyces coelicolor increases the production of undecylprodigiosin when interacted with Bacillus subtilis
...Show More Authors

View Publication
Scopus (31)
Crossref (27)
Scopus Clarivate Crossref
Publication Date
Thu Jun 30 2022
Journal Name
Iraqi Journal Of Laser
PDF Treatment of intraoral pyogenic granuloma with diode laser 810-980 nmarch
...Show More Authors

Background: Pyogenic granuloma is a hyperplastic benign tumor. The most common intra-oral site is marginal gingiva. It is often occurred in the second decade of life, it has a strong tendency to recur after simple excision.

The aim of study: to evaluate the therapeutic advantages of diode laser (810-980 nm) in intraoral Pyogenic granuloma management.

Materials and method: A total of 28 patients (14 men and 14 females) were enrolled in this study and had their pyogenic granuloma surgically removed using a diode laser. All of the patients were given local anesthetic and went through the identical surgical procedure (cartridge containing 1 percent lidocaine with epinephrine 1:

... Show More
View Publication Preview PDF
Publication Date
Thu Feb 01 2024
Journal Name
Journal Of Engineering
Numerical Study of Composite Concrete Castellated Double Channel Beams with Strengthening Techniques
...Show More Authors

Current numerical research was devoted to investigating the effect of castellated steel beams without and with strengthening. The composite concrete asymmetrical double hot rolled steel channels bolted back to back to obtain a built-up I-shape form are used in this study. The top half part of the steel is smaller than the bottom half part, and the two parts were connected by bolting and welding. The ABAQUS/2019 program employed the same length and conditions of loading for four models: The first model is the reference without castellated and strengthening; the second model was castellated without strengthened; the third model was castellated and strengthened with reactive powder concrete encased in the

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Tue Mar 03 2026
Journal Name
Buildings
Behavior of Stiffened Stainless-Steel Tube Columns Filled with Steel Fiber Concrete
...Show More Authors

This research explored the performance of steel fiber concrete-filled stainless-steel tube columns stiffened with embedded carbon steel T-sections with various steel fiber ratios under biaxial bending conditions. A numerical parametric analysis was adopted, using finite element modeling with Abaqus CAE/2021 to evaluate the effects of the fiber ratio (ranging from 0% to 1.5%) on the load-bearing capacity and deflection behavior of columns. In addition, the compressive strength of concrete ranged between 45 and 65 MPa. An increase in the fiber ratio led to a substantial improvement in the ultimate load-bearing capacity (up to 24%), a reduction in deflection (of approximately 49%), and an improvement in column ductility, which were obt

... Show More
View Publication
Scopus Crossref
Publication Date
Wed Apr 01 2020
Journal Name
Applied Acoustics
Wideband sound absorption of a double-layer microperforated panel with inhomogeneous perforation
...Show More Authors

Micro-perforated panel (MPP) absorber is increasingly gaining popularity as an alternative sound absorber in buildings compared to the well-known synthetic porous materials. A single MPP has a typical feature of a Helmholtz resonator with a high amplitude of absorption but a narrow absorption frequency bandwidth. To improve the bandwidth, a single MPP can be cascaded with another single MPP to form a double-layer MPP. This paper proposes the introduction of inhomogeneous perforation in the double-layer MPP system (DL-iMPP) to enhance the absorption bandwidth of a double-layer MPP. Mathematical models are proposed using the equivalent electrical circuit model and are validated with experiments with good agreement. It is revealed that the DL-

... Show More
View Publication
Scopus (66)
Crossref (51)
Scopus Clarivate Crossref
Publication Date
Sun May 12 2019
Journal Name
Al-khwarizmi Engineering Journal
Motion Control of Three Links Robot Manipulator (Open Chain) with Spherical Wrist
...Show More Authors

Robot manipulator is a multi-input multi-output system with high complex nonlinear dynamics, requiring an advanced controller in order to track a specific trajectory. In this work, forward and inverse kinematics are presented based on Denavit Hartenberg notation to convert the end effector planned path from cartesian space to joint space and vice versa where a cubic spline interpolation is used for trajectory segments to ensure the continuity in velocity and acceleration.  Also, the derived mathematical dynamic model is based on Eular Lagrange energy method to contain the effect of friction and disturbance torques beside the inertia and Coriolis effect. Two types of controller are applied ; the nonlinear computed torque control (CTC

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Sun Apr 30 2023
Journal Name
Iraqi Journal Of Science
Evaluation of Hematological Factors and Micronutrients Among Children Infected with Enterobius vermicularis
...Show More Authors

     Malnutrition, anemia, and micronutrient deficits may be associated with Enterobius vermicularis infection. Hence, the subject has recently received a lot of attention. The goal of this study was to analyse the nutritional, hematological and micronutrient status of children infected with E. vermicularis. This research was carried out in Baghdad from October 2021 to the end of March 2022. The study comprised 100 children of both sexes, ranging in age from 3-16 years. All individuals nutritional status was assessed using the weight-for-age Z score and the height-for-age Z score. As well as cellophane tape samples and blood samples were collected from all individuals. The cellophane tape samples were examined under microscope f

... Show More
Preview PDF
Scopus (5)
Crossref (3)
Scopus Crossref