Preferred Language
Articles
/
bijps-409
Preparation and Evaluation of Liquid and Solid Self-Microemulsifying Drug Delivery System of Mebendazole
...Show More Authors

The aim of present study was to develop solid and liquid  self-microemulsifying drug  delivery system of poorly water soluble drug mebendazole using Aerosil 200 as solid carrier.  Microemulsions are clear, stable, isotropic liquid mixtures of oil, water and surfactant, frequently in combination with a co-surfactant having droplet size range usually in the range of 20-250 nm. Oleic acid, tween 80 and polypropylene glycol were selected as oil, surfactant and co-surfactant respectively and for preparation of stable SMEDDS, micro emulsion region was identified by constructing pseudo ternary phase diagram containing different proportion of surfactant: co-surfactant (1:1, 2:1 and 3:1), oil and water. In brief S/ CoS mix means surfactant to co-surfactant and oil were mixed at ratio of 1:9, 2:8, 3:7, 4:6, 5:5, 6:4, 7:3, 8:2 and 9:1 manner. To the resultant mixtures, water was added drop wise till the first sign of turbidity in order to identify the end point and after equilibrium; if the system became clear then the water addition was continued. Prepared optimised formula of microemulsion was evaluated for SEM, particle size analysis, polydispersity index, phase separation, viscosity determination, zeta potential, in- vitro dissolution study and in- vivo studies. The optimized microemulsion was converted into solid form by Spray Drying technique by using Aerosil 200 as solid carrier. Prepared SMEDDS was characterized for same parameters as that of microemulsion. Solid SMEDDS of mebendazole prepared using Aerosil 200 by spray drying technique showed good drug content uniformity. After reconstitution it formed microemulsion with micrometric range. In-vitro drug release and in-vivo plasma drug concentration of microemulsion and SMEDDS was much higher than that of marketed praparation. Hence lipid based drug delivery system may efficiently formulate microemulsion and it can be solidified easily by spray drying technique which enhances dissolution rate and thus concomitantly bioavailability. In conclusion ,self micro emulsifying drug delivery system has become promising tool to overcome shortcomings associated with conventional delivery.

Kew words: Self-microemulsifying drug  delivery system, Microemulsion, Mebendazole.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Jun 25 2020
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Formulation and Evaluation of Iornoxicam as Dissolving Microneedle Patch
...Show More Authors

The objective of the study was to develop microneedle (MN) patch, with suitable properties to ensure the delivery of a therapeutic level of lornoxicam (LXM) in a period suitable to replace parenteral administration in patients, especially those who fear needles. The used polymers were cold water-soluble polyvinyl alcohol (PVA) and polyvinylpyrrolidone (PVP) of low molecular weight with PEG 400 as plasticizer and Tween 80 (to enhance the release) using micro molding technique. Patches were studied for needle morphology, drug content, axial fracture force measurement and drug release while the optimized formulas were further subjected to pH measurement, folding endurance, ex vivo permeation study, histopathology study, stability study and

... Show More
View Publication Preview PDF
Scopus (23)
Crossref (15)
Scopus Crossref
Publication Date
Mon Dec 20 2021
Journal Name
Baghdad Science Journal
Evaluation Method of Mesh Protocol over ESP32 and ESP8266
...Show More Authors

Internet of Things (IoT) is one of the newest matters in both industry and academia of the communication engineering world. On the other hand, wireless mesh networks, a network topology that has been debate for decades that haven’t been put into use in great scale, can make a transformation when it arises to the network in the IoT world nowadays. A Mesh IoT network is a local network architecture in which linked devices cooperate and route data using a specified protocol. Typically, IoT devices exchange sensor data by connecting to an IoT gateway. However, there are certain limitations if it involves to large number of sensors and the data that should be received is difficult to analyze. The aim of the work here is to implement a self-

... Show More
View Publication Preview PDF
Scopus (23)
Crossref (12)
Scopus Clarivate Crossref
Publication Date
Tue Aug 23 2022
Journal Name
Frontiers In Energy Research
Evaluation of T-Shaped Fins With a Novel Layout for Improved Melting in a Triple-Tube Heat Storage System
...Show More Authors

The effects of T-shaped fins on the improvement of phase change materials (PCM) melting are numerically investigated in vertical triple-tube storage containment. The PCM is held in the middle pipe of a triple-pipe heat exchanger while the heat transfer fluid flows through the internal and external pipes. The dimension effects of the T-shaped fins on the melting process of the PCM are investigated to determine the optimum case. Results indicate that while using T-shaped fins improves the melting performance of the PCM, the improvement potential is mainly governed by the fin’s body rather than the head. Hence, the proposed T-shaped fin did not noticeably improve melting at the bottom of the PCM domain; additionally, a flat fin is ad

... Show More
View Publication
Scopus (54)
Crossref (40)
Scopus Clarivate Crossref
Publication Date
Sat Jan 02 2021
Journal Name
International Journal Of Pharmaceutical Research
Detection of Kaposi’s Associated Herpesvirus in Saliva of Drug Related Immunosupressed Patient
...Show More Authors

View Publication
Crossref
Publication Date
Sat Jun 30 2007
Journal Name
Al-kindy College Medical Journal
Perinatal out come of Breech Presentation in the Presentation in the Pretext Mode of Delivery
...Show More Authors

Objectives: To choose the best mode of delivery
for term, frank or complete, breech presentation
through studying the perinatal outcome of each mode of
delivery decided when managing a group of pregnant
ladies presented with breech delivery in our centre.
Methods: One hundred and fifty pregnant ladies
presented at term with singleton, frank or complete,
breech presentation for delivery in our centre during the
period from May 2004 toAugust 2005.
Mode of delivery, parity, gestational age, maternal age,
maternal medical illness, and birth weight where the
variables that have been tested in each delivery
included in the study to verify their relationship to
perinatal outcome.
Results: No significant

... Show More
View Publication Preview PDF
Publication Date
Tue Feb 01 2022
Journal Name
Advanced Powder Technology
Functionalization of mesoporous MCM-41 for the delivery of curcumin as an anti-inflammatory therapy
...Show More Authors

View Publication
Scopus (100)
Crossref (99)
Scopus Clarivate Crossref
Publication Date
Thu Jan 23 2020
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
Impact of self-assessment on income and sales tax collections from the point of view of income tax auditors in Jordan
...Show More Authors

This study aimed to show the extent of compliance with the income taxpayer  to provide tax returns and increase the speed of collection of these taxes in addition to increasing confidence in  Income Tax department and reduce the number of cases transferred to the courts and promote taxpayer awareness in charge of the importance of system self-assessment, and study sought to investigate the effect of the existence of records documents, technical audit, and computational audit and documentary audit on income tax collections in Jordan, from the point of view of Jordanian income tax auditors ,results shows there's a strong  relation between these variables and Income Tax collections.

View Publication Preview PDF
Publication Date
Fri May 22 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of nano surface modification on CPTi dental implant using chemical method: mechanical and histological evaluation
...Show More Authors

Background The application of nanotechnology to biomedical surfaces is explained by the ability of cells to interact with nanometric features. The aim of this study was to consider the role of nanoscale topographic modification of CPTi dental implant using chemical etching method for the purpose of improving osseointegration. Materials and methods: Commercial pure titanium rod was machined into 20 dental implants. Each implant was machined in diameter about 3mm, length of 8mm (5mm was threaded part and 3mm was flat part). Implants were prepared and divided into 2 groups according to the types of surface modification method used: 1st group (10 implant) remained without nano surface modification (control), 2nd group include (10 implant) etche

... Show More
View Publication Preview PDF
Publication Date
Fri May 24 2024
Journal Name
Molecular Crystals And Liquid Crystals
Synthesis and liquid crystalline properties of novel series containing 5H-thiazolo[3,4-b][1, 3, 4]thiadiazole unit with schiff base and azo linkage
...Show More Authors

View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Fri Dec 01 2023
Journal Name
Iop Conference Series: Earth And Environmental Science
The Effect of Power Sources in the Agricultural Tractor and the Developed Sprayer System on the Performance of the Electrical and Mechanical Sprayer System and some Performance Indicators of the Engine
...Show More Authors
Abstract<p>An experiment was conducted to study the effect of the sprayer type according to the source of power and the size of the spray nozzle concerning the quality of the spray produced and fuel consumption.Two types of sprayers were used: a conventional boom sprayer (S1) and a modified (electrified) boom sprayer (S2), along with three sizes of the XR TeeJet 110 spray nozzle (N). The following technical performance indicators were examined: Density of coverage (drops/cm2) using ImageJ software, a 600dpi business card scanner, specifically the ScanShell 800N by CSSN, Inc, and water-sensitive paper (WSP), rate of spray nozzles discharge (ml/min), and fuel consumption (liters/hectare) using a c</p> ... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Crossref