Preferred Language
Articles
/
bijps-367
Bioequivalence and Pharmacokinetics Comparison of Two Formulations of Extended-Release Pentoxifylline Tablets in Healthy Subjects after Fasting and Fed Conditions
...Show More Authors

The pharmacokinetics and bioequivalence of a newly developed extended-released (ER) tablet containing 400 mg pentoxifylline as a test product was compared with the reference brand product Trental® 400 mg ER tablet produced by Sanofi-Aventis. Two separate studies were conducted simultaneously. The first study was conducted under fasting condition, whereas, the second study was conducted under fed condition; using the same batches of the test and reference products in both studies. In each study, both products were administered to 32 healthy male adult volunteers applying a single-dose, two-treatment, two-period, two-sequence, randomized crossover design with one-week washout period between dosing. Twenty two blood samples were withdrawn from each volunteer over 24 hours period.  Pentoxifylline concentrations were determined in plasma by a validated HPLC method according to FDA Bioanalytical Method Validation Guidance using UV detection and chloramphenicol as internal standard. The lower limit of quantitation of the drug in plasma was 5 ng/ml and the upper limit of quantitation was 500 ng/ml. From the plasma concentration-time data of each individual, the pharmacokinetic parameters; Cmax,  AUC0-t, AUC0-Â¥, Cmax/AUC0-Â¥, Tmax, lZ & T0.5; were calculated applying non-compartmental analysis. Data of the test and reference products were statistically analyzed to test for bioequivalence of the two products, using criteria of FDA and EMEA Guidance.  The pharmacokinetic parameters mentioned above were statistically analyzed by descriptive statistics, ANOVA test and 90% Confidence Interval (CI). ANOVA test involved the calculation of the effects of: treatment, period, sequence and subjects nested in sequence. According to the above guidance, the primary pharmacokinetic parameters used for bioequivalence testing, namely Cmax, AUC0-t and AUC0-Â¥ were also statistically analyzed by ANOVA & CI tests using the corresponding Ln-transformed values. The mean values  Cmax,  AUC0-t , AUC0-Â¥ , Cmax/AUC0-Â¥ , Tmax, lZ & T0.5 for the test formula obtained from the fasting study  were; 144.4 ng/ml,  845.4 ng.hr/ml, 868.4 ng.hr/ml, 0.186 hr-1, 3.29 hr, 0.561 hr-1 and 1.65 hr, respectively; and the mean values of these parameters for the reference formula were; 150.0 ng/ml,  871.1 ng.hr/ml, 893.7 ng.hr/ml, 0.177 hr-1, 3.70 hr, 0.558 hr-1 and 1.59 hr,  respectively.  The mean values of the above mentioned parameters for the test formula obtained from the fed study were; 157.8 ng/ml, 826.5 ng.hr/ml, 853.8 ng.hr/ml, 0.198 hr-1, 5.4 hr, 0.458 hr-1 and 2.06 hr, respectively; and the mean values of these parameters for the reference formula were; 162.1 ng/ml, 869.7 ng.hr/ml, 894.8 ng.hr/ml, 0.196 hr-1, 4.1 hr, 0.525 hr-1 and 1.80 hr, respectively.  Based on criteria of FDA and   EMEA Guidance on Bioavailability and Bioequivalence, the results of the fasting and fed studies demonstrated bioequivalence of the two products under either condition. Accordingly, it is concluded that the newly developed ER tablet containing 400 mg pentoxifylline is bioequivalent to Trental® 400 mg ER tablet produced by Sanofi-Aventis.

Keywords: Pentoxifylline, Pharmacokinetics, Bioequivalence.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Mar 01 2023
Journal Name
Egyptian Journal Of Chemistry
First- and Second-Derivative Spectrophotometry for Simultaneous Determination of lorazepam and clonazepam in pharmaceutical formulations
...Show More Authors

The present study describes employing zero-, 1st - and 2nd -order derivative spectrophotometric methods have been developed for determination of lorazepam (LORA) and clonazepam (CLON) in commercially available tablets. LORA was determined by means of 1st (D1), 2nd (D2) derivative spectrophotometric techniques using zero cross, peak height, and Peak area. D1 used for the determination of CLON by using zero cross and peak height while D2 (zero cross) was used for the determination of CLON. The method was established to be linear in concentration containing different ratios of LORA and CLON range of (20-200 mg/L) and (5-35 mg/L) at wavelength range (250 -370 nm), (210-370nm) respectively. The proposed techniques are highly sensitive, precise a

... Show More
Preview PDF
Publication Date
Wed Jun 29 2022
Journal Name
Egyptian Journal Of Chemistry
First- and Second-Derivative Spectrophotometry for Simultaneous Determination of lorazepam and clonazepam in pharmaceutical formulations.
...Show More Authors

View Publication Preview PDF
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Fri Mar 01 2019
Journal Name
2019 9th International Ieee/embs Conference On Neural Engineering (ner)
Differences in EMG Feature Space between Able-Bodied and Amputee Subjects for Myoelectric Control
...Show More Authors

View Publication
Scopus (25)
Crossref (23)
Scopus Clarivate Crossref
Publication Date
Mon May 20 2019
Journal Name
The Journal Of Engineering
Experimental comparison of two linear machines developed for the free piston engine
...Show More Authors

: In this study, a linear synchronous machine is compared with a linear transverse flux machine. Both machines have been designed and built with the intention of being used as the power take off in a free piston engine. As both topologies are cylindrical, it is not possible to construct either using just flat laminations and so alternative methods are described and demonstrated. Despite the difference in topology and specification, the machines are compared on a common base in terms of rated force and suitability for use as a generator. Experience gained during the manufacture of two prototypes is described.

View Publication Preview PDF
Crossref (9)
Clarivate Crossref
Publication Date
Wed Oct 17 2018
Journal Name
Journal Of Economics And Administrative Sciences
Comparison of Two of (Turnbull) and (Generalization Turnbulls)non-parametric methods in estimating conditional survival function (applied study on breast cancer patients)
...Show More Authors

   This research includes the application of non-parametric methods in estimating the conditional survival function represented in a method (Turnbull) and (Generalization Turnbull's) using data for Interval censored of breast cancer and two types of treatment, Chemotherapy and radiation therapy and age is continuous variable, The algorithm of estimators was applied through using (MATLAB) and then the use average Mean Square Error (MSE) as amusement  to the estimates and the results showed (generalization of Turnbull's) In estimating the conditional survival function and for both treatments ,The estimated survival of the patients does not show very large differences

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Feb 27 2021
Journal Name
Journal Of Engineering
Design and Simulation of a controller for Double Fed Induction Generator turbine Utilized Solar Up Draft Tower
...Show More Authors

This paper introduces a complete design and simulation of a controller for the double fed induction generator (DFIG) turbine. The work also included the solar updraft tower (SUT) design to supply Al-Mahmoudia hospital in Baghdad/Iraq. The design includes the daily average load estimation, annual solar irradiance and, temperature monitoring, and logging.

According to the data obtained from the Ministry of Science and Technology, Baghdad has low wind speed. Therefore, the (SUT) has been designed to generate electrical power depending on the difference between the external and internal air temperature. The temperature difference will generate a suitable airspeed to drive the wind turbine, connected to the proposed (DFIG) generators

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Annals Of Tropical Medicine And Public Health
SPECTROPHOTOMETRIC DETERMINATION OF DIPHENHYDRAMINE HCL IN PURE AND PHARMACEUTICAL FORMULATIONS USING THYMOL BLUE
...Show More Authors

This approach was developed to achieve an accurate, fast, economic and sensitivity to estimation of diphenhydramine Hydrochloride. The dye that produced via reaction between diphenhydramine HCl with thymol blue in acidic medium pH ≈ 4.0. The ion pair method include an optimization study to formed yellowcolored that extraction by liquid – liquid method. The product separated of complexes by using by chloroform solution measured spectrophotometry at 400 nm. The analysis data at optimum conditions showed that linearity concentration in a range of calibration curve 1.0 – 50 μg /mL, limit of detectionand limit of quantification 0.0786 and 0.2358 μg/mL respectively. The molar absorptivity and Sandell’s sensitivity were 1.8 × 10 -4 L/mo

... Show More
View Publication
Crossref
Publication Date
Thu Jun 01 2023
Journal Name
Baghdad Science Journal
Batch and flow injection spectrophotometric methods for determination of Ceftazidime in pharmaceutical formulations
...Show More Authors

It is generally accepted that there are two spectrophotometric techniques for quantifying ceftazidime (CFT) in bulk medications and pharmaceutical formulations.  The methods  are described as simple, sensitive, selective, accurate and efficient techniques. The first method used an alkaline medium to convert ceftazidime to its diazonium salt, which is then combined with the 1-Naphthol (1-NPT) and 2-Naphthol (2-NPT) reagents. The azo dye that was produced brown  and red in color with absorption intensities of ƛmax 585 and 545nm respectively. Beer's law was followed in terms of concentration ranging from  (3-40) µg .ml-1 For (CFT-1-NPT) and (CFT-2-NPT), the detection limits were 1.0096 and 0.8017 µg.ml-1, respec

... Show More
View Publication Preview PDF
Scopus (3)
Scopus Crossref
Publication Date
Sun Sep 01 2019
Journal Name
Baghdad Science Journal
Kinetic- spectrophotometric Method for the Determination of Naringenin in Pure and Supplements Formulations
...Show More Authors

          Simple, cheap, sensitive, and accurate kinetic- spectrophotometric method has been developed for the determination of naringenin in pure and supplements formulations. The method is based on the formation of Prussian blue. The product dye exhibits a maximum absorbance at 707 nm. The calibration graph of naringenin was linear over the range 0.3 to 10 µg ml-1 for the fixed time method (at 15 min) with a correlation coefficient (r) and percentage linearity (r2%) were of 0.9995 and 99.90 %, respectively, while the limit of detection LOD was 0.041 µg ml-1. The method was successfully applied for the determination of naringenin in supplements with satisfac

... Show More
View Publication Preview PDF
Scopus (2)
Scopus Clarivate Crossref
Publication Date
Tue Jul 13 2021
Journal Name
Journal Of Craniofacial Surgery
Comparison of Two Botulinum Toxin Injection Methods for Treatment of Excessive Gingival Display
...Show More Authors

Background: Hyperfunction of the muscles of the upper lip is considered as the most common cause of excessive gingival display (EGD). The aim of this study was to demonstrate the effectiveness of botulinum toxin (BT) injection as a conservative treatment for EGD due to muscular hyperfunction and to compare the outcome of 2 injection methods. Material and methods: This study included 40 participants who were randomly assigned into 2 groups of 20 each, The first group received 2.5IU BT injection at 1 point per side (2-points group), while the second group received a total of 5 IU of BT at 2 points per side (4-points group). The outcome variables were the reduction in the central and lateral gingival display expressed as the difference between

... Show More
View Publication
Scopus (3)
Crossref (7)
Scopus Clarivate Crossref