Preferred Language
Articles
/
bijps-359
The Spectrophotometric Determination of Olanzapine via Coupling with Diazotized p-Nitroaniline
...Show More Authors

A new spectrophotometric method has been developed for the assay of olanzapine (OLN.) in pure and dosage forms. The method is based on the diazocoupling of (OLN.) with diazotized p-nitroaniline in alkaline medium to form a stable brown colored water-soluble azo dye with a maximum absorption at 405 nm.  The variables that affect the completion of reaction have been carefully optimized. Beer’s law is obeyed over the concentration range of (0.5-45.0 μg.mL-1) with a molar absorptivity of 1.5777×104 L.mol-1.cm-1.  The limit of detection was  0.3148  Î¼g.mL-1 and  Sandell’s  sensitivity value was 0.0198 μg.cm-2. The proposed method has been applied successfully to the determination of olanzapine in tablet pharmaceutical preparations.

Keywords: Spectrophotometry, Olanzapine, Diazotization, p-nitroaniline, tablet dosage form. 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat May 30 2026
Journal Name
Iraqi Journal Of Science
Simultaneous determination of a mixture of beta-lactam drugs in their pure forms and pharmaceutical preparation using high performance liquid chromatography with an ultraviolet detecto
...Show More Authors

A modern, rapid RP-HPLC-UV method was developed and validated in compliance with FDA and EMA guidelines for simultaneous quantification of 15 βlactam antibiotics) Ampicillin, Amoxicillin, cephalexin, cefotaxime, cefoxitin, cefamandole, cephalothin, piperacillin, penicillin, oxacillin, cloxacillin, nafcillin Carbenicillin, Mezlocillin and Dicloxacillin) in pharmaceutical formulations and pure forms. The method employs Column NEUCLEODUR C-18 (4.0 mm x 100 mm, 5µm particle size), at a temperature of thirty degrees Celsius, and the mobile phase was acetonitrile and KH2PO4 using gradient elution with a total separation time of 13 minutes, a flow rate of 1.3 ml/min, at = pH 4.5 for the buffer solution and the λ max was 220 nm. The met

... Show More
Publication Date
Fri Dec 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Determination of Implant Primary Stability: A Comparison of the Surgeon’s Tactile Sense and Objective Measurements
...Show More Authors

Background: Evaluation and measurement of primary stability could be achieved by several methods, including the resonance frequency analysis (RFA) and implant insertion torque (IT) values. The need for a sufficient primary stability, guaranteed by an adequate insertion torque and implant stability quotient values, increased its importance mainly in one stage implants or in immediate loading protocols. The aims of this study was to find if there is a correlation between the peak insertion torque (PIT) and ISQ values of implants inserted in the jaws of different bone quality which regarded as two important clinical determinant factors for prediction of implant primary stability, and to evaluate and compare whether an experienced clinician cou

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Jul 20 2020
Journal Name
Biochemical And Cellular Archive
DETERMINATION OF POLYMORPHISM OF GLUTATHIONE S TRANSFERASE (GST) IN THE IRAQI (DIABETIC AND NON-DIABETIC) ACROMEGALIC PATIENTS
...Show More Authors

In Iraqi patients with acromegaly the present investigation included 40 control group and 70 patients with acromegaly divided 35 patients with Diabetic while another 35 patients without Diabetic, with ages between (29-72) years for the identification of GST activity polymorphisms by present and absent GSTM1, GSTT1, and PCR-RFLP, enzymatic digestions were carried out using BsmAI (Biolabs. England, UK) for GSTP1b and AciI (Biolabs, England, UK) for GSTP1c.the association GSTActivity with GST genotype were investigated in a cohort of Iraq acromegaly patients comparing with the healthy control group. The results show a non-significant change in GSTP1b gene in both groups, while show high significantly in GSTP1c in diabetic and non-diabetic acro

... Show More
Preview PDF
Publication Date
Thu Jan 30 2025
Journal Name
Iraqi Journal Of Science
Development of A New Colorimetric-Flow System Approach for The Determination of Cefotaxime Sodium in Pharmaceutical Formulations
...Show More Authors

     A new colorimetric-flow injection method has been developed and validated for the detection of Cefotaxime sodium in pharmaceutical formulations. This method stands out for its rapid and sensitive nature. The formation of a brown-colored complex between Cefotaxime sodium and the Biuret reagent in a highly alkaline environment serves as the basis for the detection. The intensity of this colored complex is measured using a custom-built Continuous Flow Injection Analyzer, enabling accurate quantification of Cefotaxime sodium. Optimization studies of the chemical and physical parameters such as dilution of Biuret reagent, effect of the medium basicity, flow rate, sample loop and others have been investigated. The calibration gra

... Show More
View Publication
Scopus (3)
Scopus Crossref
Publication Date
Sat Mar 01 2008
Journal Name
Iraqi Journal Of Physics
The Determination of Lower Limit Detection of X-Ray Fluorescence for Zinc Powder Suspended in Engine Oil
...Show More Authors

In this work Different weight of pure Zinc powder suspended particles in 4ml base engine Oil were used.
Intensity of Kα Line was measured for the suspended particles ,also for mixture which consist from Zinc particle blended with Engine base Oil. Calibration Curve was drawn between Ikα line Intensity and Zinc concentration at different operation condition. The Lower Limit detection (LLD) and Sensitivity (m) of Spectrometer were determined for different Zinc Concentration (Wt%). The results of LLD and m for Samples were analyzed at Operation Condition of 30KV,17mA is best from Samples were analyzed at Operation Condition of 25KV,15mA

View Publication Preview PDF
Publication Date
Fri Jun 01 2012
Journal Name
Journal Of Biotechnology Research Center
Determination the titer antibodies against LPS extracted from Pseudomonas aeruginosa isolated from eye infection
...Show More Authors

Preview PDF
Publication Date
Sat Dec 01 2012
Journal Name
Journal Of Economics And Administrative Sciences
Eatimation Availability Function Through Determination The Optimal Imperfect Preventive Maintenance Period By using Simulation
...Show More Authors

This paper deals with the modeling of a preventive maintenance strategy applied to a single-unit system subject to random failures.

According to this policy, the system is subjected to imperfect periodic preventive maintenance restoring it to ‘as good as new’ with probability

p and leaving it at state ‘as bad as old’ with probability q. Imperfect repairs are performed following failures occurring between consecutive

preventive maintenance actions, i.e the times between failures follow a decreasing quasi-renewal process with parameter a. Considering the

average durations of the preventive and corrective maintenance actions a

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jun 01 2025
Journal Name
Journal Of Physics: Conference Series
Determination of Radioactivity Levels in Some Rice Samples available in the Iraqi Markets Using the system of High-purity Germanium
...Show More Authors
Abstract<p>This study aimed to determine the radioactivity and radiation hazard indicators of rice samples potentially for human consumption. Gamma spectroscopy was used to calculate the specific activity of natural and artificial radionuclides (<sup>238</sup>U, <sup>232</sup>Th, <sup>40</sup>K, and <sup>137</sup>Cs) in local and imported rice samples collected from local markets in Baghdad Governorate, Iraq, in addition to various radiological hazard indices. The radionuclide concentrations in the samples varied from 2.123 ± 1.457 Bq/kg to 13.032 ± 3.610 Bq/kg for <sup>238</sup>U, 2.906 ± 1.705 Bq/kg to 17.290 ± 4.158 Bq/kg for <sup>232</sup></p> ... Show More
View Publication
Scopus Crossref
Publication Date
Sat Jun 30 2007
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Determination of Volumetric Mass Transfer Coefficient in Fixed Bed Adsorption
...Show More Authors

This work was conducted to determine the volumetric mass transfer coefficient (Ky.a) infixed bed adsorption using hexane-benzene mixture by adsorption onto a fixed bed of white silica gel. Benzene concentration was measured by gas chromatography. The effect of feed flow rate and initial concentration of benzene in hexane-benzene mixture on the volumetric mass transfer coefficient and on the adsorption capacity of silica gel was investigated.

In general, the volumetric mass transfer coefficient increases with increasing hexane flow rate, and with increasing initial concentration of benzene in the mixture. The ultimate value of (Ky.a) was at 53 ml/min of hexane flow rate with benzene initial concentration of (6.53 wt. %), and it wa

... Show More
View Publication Preview PDF
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
linear equivalence determination of key-stream sequence using Z-Transform
...Show More Authors

the research ptesents a proposed method to compare or determine the linear equivalence of the key-stream from linear or nonlinear key-stream

View Publication Preview PDF