Preferred Language
Articles
/
bijps-2000
Formulation Variables Effect on Gelation Temperature of Nefopam Hydrochloride intranasal in Situ Gel (Conference Paper) #
...Show More Authors

Nefopam (N.F.) HCl is a non-narcotic centrally-acting, non-opioid benzoxazocine analgesic to relieve acute and chronic pain. It exhibits low bioavailability (about 36%) due to its first-pass degradation in the liver.

Intranasal administration has been used as a new route for targeting active brain sites and enhancing the bioavailability of N.F. HCl bypassing hepatic metabolism.

In situ gel of N.F. HCl was prepared by the cold method using different concentrations of Poloxamer 407, Poloxamer 188, HPMC K4M, Carbapol 934, and Hyaluronic acid polymers.

The results show that identification tests are superimposed with references, solubility study shows that N.F. HCl is suitable to be administered intranasally; Compatibility studies reveal incompatibility of Nefopam HCl with HPMC K4M and Carbapol 934; meanwhile, no interaction with Methylcellulose and Hyaluronic acid.

In conclusion, the obtained results revealed the incredible ability of the produced N.F. HCl intranasal in situ gel is intended to enhance drug bioavailability bypassing the metabolizing effect of the liver that N.F. HCl is facing when given orally.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Dec 30 2002
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Vapor Phase Oxidation of Benzoic Acid to Phenol using Nickel-Iron Oxides Catalysts
...Show More Authors

View Publication Preview PDF
Publication Date
Sat Oct 29 2022
Journal Name
Current Trends In Geotechnical Engineering And Construction
Simulation Design and Performance of a Residential Complex Using Liquefied Petroleum Gas Network
...Show More Authors

The population has been trying to use clean energy instead of combustion. The choice was to use liquefied petroleum gas (LPG) for domestic use, especially for cooking due to its advantages as a light gas, a lower cost, and clean energy. Residential complexes are supplied with liquefied petroleum gas for each housing unit, transported by pipes from LPG tanks to the equipment. This research aims to simulate the design and performance design of the LPG system in the building that is applied to a residential complex in Baghdad taken as a study case with eight buildings. The building has 11 floors, and each floor has four apartments. The design in this study has been done in two parts, part one is the design of an LPG system for one building, an

... Show More
View Publication
Scopus Crossref
Publication Date
Mon Feb 01 2016
Journal Name
Journal Of Civil Engineering Research
Distribution Factor of Curved I-Girder Bridges under Iraqi Standard Bridge Live Loads
...Show More Authors

View Publication Preview PDF
Publication Date
Sun Dec 02 2012
Journal Name
Baghdad Science Journal
Unsteady Magnetohydrodynamics oscillating flow of third order fluid with central free stream velocity
...Show More Authors

In this article the unsteady magnetohydrodynamics oscillating flow of third order fluid with free stream velocity is proposed. It is found that the motion equation is controlled by five dimensionless parameters namely the coecostic parameter 4, viscoelostic parameter ?,acceleration/deceleration c,suction/blowing d and material constants ? . The effect of each of these parameters upon the velocity distribution is analysised

View Publication Preview PDF
Crossref
Publication Date
Fri Feb 01 2019
Journal Name
Journal Of The College Of Education For Women
Arabic prose poem and the antithesis of contrast: poetry _ prose and West _ East
...Show More Authors

Arabic prose poem and the antithesis of contrast: poetry _ prose and West _ East

View Publication Preview PDF
Publication Date
Sat May 01 2021
Journal Name
Key Engineering Materials
Synthesis and Characterization of the Thin Films NiSe2/Si Heterojunction for Solar Cells
...Show More Authors

Thin film solar cells are preferable to the researchers and in applications due to the minimum material usage and to the rising of their efficiencies. In particular, thin film solar cells, which are designed based one transition metal chalcogenide materials, paly an essential role in solar energy conversion market. In this paper, transition metals with chalcogenide Nickel selenide termed as (NiSe2/Si) are synthesized. To this end, polycrystalline NiSe2 thin films are deposited through the use of vacuum evaporation technique under vacuum of 2.1x10-5 mbar, which are supplied to different annealing temperatures. The results show that under an annealed temperature of 525 K,

... Show More
View Publication
Scopus Crossref
Publication Date
Sun Sep 01 2013
Journal Name
Baghdad Science Journal
Solvent Extraction And Spectrophotomteric Determination Of Cu(Ii) With Dicyclohexyl - 18- Crown-6
...Show More Authors

Liquid-Liquid Extraction of Cu(II) ion in aqueous solution by dicyclohexyl-18-crown-6 as extractant in dichloroethane was studied .The extraction efficiency was investigated by a spectrophometric method. The reagent form a coloured complex which has been a quantitatively extracted at pH 6.3. The method obeys Beer`s law over range from (2.5-22.5) ppm with the correlation coefficient of 0.9989. The molar absorptivity the stoichiometry of extracted complex is found to be 1:2. the proposed method is very sensitive and selective.

View Publication Preview PDF
Crossref
Publication Date
Mon Feb 07 2022
Journal Name
Innovative Infrastructure Solutions
Chemical and rheological properties of reclaimed asphalt binders modified by waste engine oil
...Show More Authors

Scopus (8)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Thu Oct 03 2024
Journal Name
Heat Transfer
Field study of a cubical integrated solar collector storage tank under Baghdad province
...Show More Authors
Abstract<p>A new, easy‐to‐manufacture, and low‐cost integrated cubical solar collector tank for domestic usage is concerned in this work. Three models are prepared, side by side, and tested to point out their seasonal performance. Tank Model I has three vertical sides, black painted and glazed to act as an absorber; the other sides are insulated. Tank Model II has two black painted and glazed sides, with four insulated surfaces. The models are south‐oriented at different positions and tested versus the conventional tank (Model III) to validate and assess their performance in summer and winter. In summer, the temperatures in Models I and II are lower than those for Model III since they have insulated sid</p> ... Show More
View Publication
Scopus (1)
Crossref (2)
Scopus Crossref
Publication Date
Sun Jul 09 2023
Journal Name
Journal Of Engineering
Performance Analysis of Four Conceptual Designs for the Air Based Photovoltaic / Thermal Collectors
...Show More Authors

The  thermal  and  electrical  performance  of  different  designs  of  air  based  hybrid photovoltaic/thermal collectors is investigated experimentally and theoretically. The circulating air is used to cool PV panels and to collect the absorbed energy to improve their performance. Four different collectors have been designed, manufactured and instrumented namely; double PV panels without cooling (model I), single duct double pass collector (model II), double duct single pass (model III), and single duct single pass (model IV) . Each collector consists of: channel duct, glass cover, axial fan to circulate air and two PV panel in parallel connection. The temperature of the upper and lower surfaces of PV panels, air temper

... Show More
View Publication
Crossref (3)
Crossref