Preferred Language
Articles
/
bijps-1794
An update on Nanoparticle Formulation Design of Piperine to Improve its Oral bioavailability: A Review
...Show More Authors

Piperine, a crystalline alkaloid compound isolated from Piper nigrum, piper longum, and other types of piper, has had many fabulous pharmacological advantages for preventing and treating some specific diseases, such as analgesic, anti-inflammatory, hepatoprotective, antimetastatic, antithyroid, immunomodulatory, antitumor, rheumatoid arthritis, osteoarthritis, Alzheimer's, and improving the bioavailability of other drugs. However, its potential for clinical use through oral usage is hindered by water solubility and poor bioavailability. The low level of oral bioavailability is caused by low solubility in water and is photosensitive, susceptible to isomerization by UV light, which causes piperine concentration to decrease. Many different formulation approaches have been applied to improve the poor oral bioavailability of piperine. There have been oral formulation strategies that have been successfully implemented in increasing the solubility and bioavailability of piperine within the body, such as the formulation of nanoparticles, nanosuspensions, salt formation, liposomes, complexation using polymers, micro/nano-emulsions, and solid dispersions. This review presents a summary of piperine biopharmaceuticals, new formulation design approaches to improve oral bioavailability of piperine, and several techniques and methods for conducting selective and sensitive analysis of piperine in biological fluids.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Apr 01 2015
Journal Name
Journal Of Engineering
Competitive Removal of Cu2+, Cd2+and Ni2+by Iron Oxide Nanoparticle (Fe3O4)
...Show More Authors

A competitive adsorption of Cu2+, Ni2+, and Cd2+ ions from a synthetic wastewater onto nanomaterial was studied.(Fe3O4) nanoparticles obtained from US Research Nanomaterials, Inc., Houston, TX 77084, (USA), was used as nanosorbent. Experimental parameters included pH, initial metal concentrations, and temperature were studied for nanosorbent. The uptake capacity 11.5, 6.07 and 11.1 mg/g for Cu2+, Ni2+and Cd2+, respectively, onto nanosorbent . The optimum pH values was 6 and the contact time was 50 min. for Cu2+, Ni2+and Cd2+, respectively. The equilibrium isotherm for

... Show More
View Publication Preview PDF
Publication Date
Wed Jun 12 2013
Journal Name
International Journal Of Computer Applications
Design and Implementation of a Practical FTTH Network
...Show More Authors

Fiber-to-the-Home (FTTH) has long been recognized as a technology that provides future proof bandwidth [1], but has generally been too expensive to implement on a wide scale. However, reductions in the cost of electro-optic components and improvements in the handling of fiber optics now make FTTH a cost effective solution in many situations. The transition to FTTH in the access network is also a benefit for both consumers and service providers because it opens up the near limitless capacity of the core long-haul network to the local user. In this paper individual passive optical components, transceivers, and fibers has been put together to form a complete FTTH network. Then the implementation of the under construction Baghdad/Al

... Show More
View Publication Preview PDF
Publication Date
Sun Feb 24 2019
Journal Name
Iraqi Journal Of Physics
Design and evalution of a solar PV system
...Show More Authors

PV connected systems are worldwide installed because it allows consumer to reduce energy consumption from the electricity grid. This paper presents the results obtained from monitoring a 1.1 kWp. The system was monitored for nine months and all the electricity generated was fed to the fifth floor for physics and renewable energy building   220 V, 50 Hz. Monthly, and daily performance parameters of the PV system are evaluated which include: average generated of system Ah per day, average system efficiency, solar irradiation around these months. The average generated kWh per day was 8 kWh/day, the average solar irradiation per day was 5.6 kWh/m2/day, the average inverter efficiency was 95%, the average modules efficien

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Dec 29 2017
Journal Name
Al-khwarizmi Engineering Journal
Design and Implementation of a Proposal Network Firewall
...Show More Authors

 

In today's world, most business, regardless of size, believe that access to Internet is imperative if they are going to complete effectively. Yet connecting a private computer (or a network) to the Internet can expose critical or confidential data to malicious attack from anywhere in the world since unprotected connections to the Internet (or any network topology) leaves the user computer vulnerable to hacker attacks and other Internet threats. Therefore, to provide high degree of protection to the network and network's user, Firewall need to be used.

Firewall provides a barrier between the user computer and the Internet (i.e. it prevents unauthor

... Show More
View Publication Preview PDF
Publication Date
Thu Nov 01 2018
Journal Name
Journal Of Economics And Administrative Sciences
The Impact of Technological Change in Process Design Decisions (Applied study in an organization)
...Show More Authors

Abstract:

     Due to the importance of technology and the accompanying changes of the environment affecting companies that use the technology mainly in their work, especially as most companies live in an unstable dynamic environment, which motivated the researchers to choose the International Company for smart card (Keycard) as a field of research and find ways to them to face Those changes.

     The problem of the study was "limited attention to the components of technological change", which included research and development, innovation and information technology, which had an impact on the design decisions of the process (process selection, cust

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat May 03 2025
Journal Name
Aip Conference Proceedings
On a graph associated to Ly group
...Show More Authors

For the graph ⁠, the behavior associated with to the majority of the graphical properties of this graph is covered in this article. The reflection of the capabilities of on the Ly constructions is one of the key ideas addressed throughout this paper. For instance, by this technique we can comprehend the mechanism via which groups of relatively tiny structure are exist within Ly.

View Publication
Scopus Crossref
Publication Date
Wed Jun 01 2016
Journal Name
Journal Of Engineering
Passive Design Strategies to Enhance Natural Ventilation in Buildings "Election of Passive Design Strategies to Achieve Natural Ventilation in Iraqi Urban Environment with Hot Arid Climate"
...Show More Authors

The natural ventilation in buildings is one of effective strategies for achieving energy efficiency in buildings by employing methods and ways of passive design, as well as its efficiency in providing high ranges of thermal comfort for occupants in buildings and raises their productivity. Because the concept of natural ventilation for many people confined to achieve through the windows and openings only, become necessary to provide this research to demonstrate the various passive design strategies for natural ventilation. Then, research problem: Insufficient knowledge about the importance and mechanism of the application of passive design strategies for natural ventilation in buildings. The research objective is: Analysis of passive desi

... Show More
View Publication Preview PDF
Publication Date
Thu Dec 01 2011
Journal Name
Journal Of Engineering
DESIGN, CONSTRUCTION AND TESTING OF LOW SPEED WIND TUNNEL WITH ITS MEASUREMENT AND INSPECTION DEVICES
...Show More Authors

A low speed open circuit wind tunnel has been designed, manufactured and constructed at the
Mechanical Engineering Department at Baghdad University - College of Engineering. The work is one of
the pioneer projects adapted by the R & D Office at the Iraqi MOHESR. The present paper describes the
first part of the work; that is the design calculations, simulation and construction. It will be followed by a
second part that describes testing and calibration of the tunnel. The proposed wind tunnel has a test
section with cross sectional area of (0.7 x 0.7 m2) and length of (1.5 m). The maximum speed is about (70
m/s) with empty test section. The contraction ratio is (8.16). Three screens are used to minimize flow
distu

... Show More
View Publication Preview PDF
Crossref (7)
Crossref
Publication Date
Tue May 19 2026
Journal Name
Journal Of Engineering
DESIGN, CONSTRUCTION AND TESTING OF LOW SPEED WIND TUNNEL WITH ITS MEASUREMENT AND INSPECTION DEVICES
...Show More Authors

A low speed open circuit wind tunnel has been designed, manufactured and constructed at the Mechanical Engineering Department at Baghdad University - College of Engineering. The work is one of the pioneer projects adapted by the R & D Office at the Iraqi MOHESR. The present paper describes the first part of the work; that is the design calculations, simulation and construction. It will be followed by a second part that describes testing and calibration of the tunnel. The proposed wind tunnel has a test section with cross sectional area of (0.7 x 0.7 m2) and length of (1.5 m). The maximum speed is about (70 m/s) with empty test section. The contraction ratio is (8.16). Three screens are used to minimize flow disturbances in the test section.

... Show More
View Publication
Publication Date
Thu Dec 01 2011
Journal Name
Journal Of Engineering
DESIGN, CONSTRUCTION AND TESTING OF LOW SPEED WIND TUNNEL WITH ITS MEASUREMENT AND INSPECTION DEVICES
...Show More Authors

A low speed open circuit wind tunnel has been designed, manufactured and constructed at theMechanical Engineering Department at Baghdad University - College of Engineering. The work is one ofthe pioneer projects adapted by the R & D Office at the Iraqi MOHESR. The present paper describes thefirst part of the work; that is the design calculations, simulation and construction. It will be followed by asecond part that describes testing and calibration of the tunnel. The proposed wind tunnel has a testsection with cross sectional area of (0.7 x 0.7 m2) and length of (1.5 m). The maximum speed is about (70m/s) with empty test section. The contraction ratio is (8.16). Three screens are used to minimize flowdisturbances in the test sec

... Show More
View Publication
Crossref (7)
Crossref