Preferred Language
Articles
/
bijps-1421
Adherence to Different Treatment Modalities among Patients on Maintenance Hemodialysis
...Show More Authors

        End Stage Renal Disease is a well-known global public health problem. Maintenance hemodialysis is considered a life-saving treatment for patients with such disease. This treatment method that requires patients to be adherent to hemodialysis attendance, dietary and fluid recommendations as well as adherence to prescribed medications to ensure success. The aim of the current study was to assess adherence, perception, and counseling among hemodialysis patients to different modalities of treatment (fluid restriction, dietary recommendations, medications, and hemodialysis schedules). A cross-sectional study carried out on hemodialysis patients who attended to the dialysis centers at al- Karama teaching hospital and Madinat Al- Imamain Al- Kadhimain teaching hospital. The  Arabic version  of the “ end stage renal disease-adherence questionnaire ” was used in assessing adherence, perception, and counseling. The number of recruited patients were 200 adult patients (113 men and 87 women). The average of the total adherence score lies within the moderate adherence (984.9 ±174.2). Patients adherence to the hemodialysis session was good as representing by high scores of adherence for (hemodialysis-attendance, episode of hemodialysis-shortening and duration of hemodialysis-shortening) while the lowest adherence score (126.0 out of 200) was for following the fluid restriction. In terms of adherence categories, the majority (61%) of the patients had good adherence, 33.0% had moderate adherence with 6% had poor adherence. Age had significant positive association with the total adherence score. All patients perceived their hemodialysis management as highly/very important. On the other hand, some patients perceived their adherence to the recommended diet as moderately (7%) or less important (7%). Regarding the frequency of counseling received by patients for different treatment modalities.  The negative answers represented 58.5% of answers about the how important is to follow a proper diet, and 25.0% of answers about the importance of taking prescribed medications as ordered. Accordingly, the overall adherence of hemodialysis patients to different treatment modalities was less than optimum with fluid and diet adherence representing most challenging tasks in the health care of hemodialysis patients.  

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Apr 01 2022
Journal Name
International Journal Of Pharmacy Practice
Exploring job satisfaction among pharmacy professionals in the Arab world: a multi-country study
...Show More Authors
Abstract<sec> <title>Objectives

The study objectives were to (1) describe the characteristics of the pharmacy professionals and (2) explore the association between job satisfaction and factors, such as work control, work stress, workload and organization and professional commitments.

Methods

This study was a cross-sectional design. The survey items were mainly adapted from the US National Pharmacist Workforce Survey. An electronic (Qualtrics) questionnaire was posted on pharmacist social media in several A

... Show More
View Publication
Scopus (13)
Crossref (9)
Scopus Clarivate Crossref
Publication Date
Wed Jan 01 2025
Journal Name
International Journal Of Body, Mind And Culture
Quality of Work Life and Resilience among Intensive Care Unit Nurses: A Descriptive Study
...Show More Authors

Objective: The present study aimed to determine the association of quality of life with the resilience of intensive care unit (ICU) nurses. Methods and Materials: A cross-sectional study was performed, including 105 ICU nurses from five hospitals in Iraq, using a convenience sample method. Data were gathered through a self-administered questionnaire that includes three sections: the demographics, the Brooks Quality of Nursing Work Life survey, and the Connor-Davidson Resilience Scale-10 (CD-RISC-10). Findings: The QWL of the ICU nurses was moderately satisfied (mean = 161.42), and the level of resilience was moderate (mean = 26). A statistically significant positive correlation between QWL and resilience. Conclusion: Strategies

... Show More
View Publication
Scopus Crossref
Publication Date
Thu Feb 26 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of shear bond strength between thermosens as relining material and different denture base materials
...Show More Authors

Background: Denture relining is the process of resurfacing of the tissue side of the ill fitting denture, the bond strength at the relining-denture base interface is most important for denture durability.The aim of present study was to evaluate the shear bond strength between the thermosens as relining material and different denture base materials that bonded by thermo fusing liquid. As this corrective procedureis the common chair side procedure in the dental clinic. Material and method: Sixty samples were prepared and divided into three main groups according to the type of denture base materials.Group (A) referred to the heat cure acrylic samples which consisted of 20 samples. Group (B) referred to the high impact acrylic samples which con

... Show More
View Publication Preview PDF
Publication Date
Sat Aug 21 2021
Journal Name
Engineering, Technology &amp; Applied Science Research
The Response of a Highly Skewed Steel I-Girder Bridge with Different Cross-Frame Connections
...Show More Authors

Braces in straight bridge systems improve the lateral-torsional buckling resistance of the girders by reducing the unbraced length, while in horizontally curved and skew bridges, the braces are primary structural elements for controlling deformations by engaging adjacent girders to act as a system to resist the potentially large forces and torques caused by the curved or skewed geometry of the bridge. The cross-frames are usually designed as torsional braces, which increase the overall strength and stiffness of the individual girders by creating a girder system that translates and rotates as a unit along the bracing lines. However, when they transmit the truck’s live load forces, they can produce fatigue cracks at their connection

... Show More
View Publication
Crossref (5)
Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of The Mechanical Behavior Of Materials
Response of composite steel-concrete cellular beams of different concrete deck types under harmonic loads
...Show More Authors
Abstract<p>This study aims to investigate the adequacy of composite cellular beams with lightweight reinforced concrete deck slab as a structural unit for harmonic loaded buildings. The experimental program involved three fixed-ends supported beams throughout 2140 mm. Three concrete types were included: Normal Weight Concrete (NWC), Lightweight Aggregate Concrete (LWAC), and Lightweight Fiber Reinforced Aggregate Concrete (LWACF). The considered frequencies were (5, 10, 15, 20, 25, and 30) Hz. It was indicated that the harmonic load caused a significant influence on LWAC response (64% greater than NWC) and lattice cracks were observed, especially at 30 Hz. As for LWACF slab, no cracks appeared, </p> ... Show More
Scopus (4)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Wed Mar 08 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Electrical Insulation Breakdown Strength and Thermal Conductivity of Different Blended Nanocomposites of New Epoxy Resins
...Show More Authors

This research studies the development and synthesis of blended nanocomposites filled with Titanium dioxide (TiO2). Blended nanocomposites based on unsaturated polyester resin (UPR) and epoxy resins were synthesized by reactive blending. The optimum quantity from nano partical of titanium dioxide was selected and different weight proportions 1%, 3%, 5%, and 7% ratios of new epoxy are blended with UPR resin. The dielectric breakdown strength and thermal conductivity properties of the blended nanocomposites were compared with those of the basis material (UPR and 3% TiO2).The results show good compatibility epoxy resins with the UPR resin on blending, dielectric breakdown strength values  are higher while thermal conductivity values of

... Show More
View Publication
Publication Date
Wed Jan 01 2020
Journal Name
Plant Archives J.
Evaluation of the performance of introduced varieties of maize under different planting dates and environments
...Show More Authors

Scopus (3)
Scopus
Publication Date
Tue Jun 20 2023
Journal Name
Baghdad Science Journal
Linear and Nonlinear Optical Properties of Anthocyanin Dye from Red Cabbage in Different pH Solutions
...Show More Authors

This article studied some linear and nonlinear optical characteristics of different pH solutions from anthocyanin dye extract at 180 oC from red cabbage. First, the linear spectral characteristics, including absorption and transmittance in the range 400-800 nm for anthocyanin solution 5% v/v with different pHs, were achieved utilizing a UV/VIS spectrophotometer. The experimental results reveal a shift in the absorption toward the longer wavelength direction as pH values increment. Then, the nonlinear features were measured using the Z-scan technique with a CW 532 nm laser to measure the nonlinear absorption coefficient through an open aperture. A close aperture (diameter 2 mm) calculates the nonlinear refractive index. The open Z-scan sh

... Show More
View Publication Preview PDF
Scopus (7)
Crossref (7)
Scopus Crossref
Publication Date
Wed Dec 01 2021
Journal Name
Computers &amp; Electrical Engineering
Utilizing different types of deep learning models for classification of series arc in photovoltaics systems
...Show More Authors

View Publication
Crossref (15)
Crossref
Publication Date
Wed Jul 31 2019
Journal Name
Journal Of Engineering
Enhancing Heat Transfer in Tube Heat Exchanger by Inserting Discrete Twisting Tapes with Different Positions
...Show More Authors

Enhancement of heat transfer in the tube heat exchanger is studied experimentally by using discrete twisted tapes. Three different positions were selected for inserting turbulators along tube section (horizontal position by α= 00, inclined position by α= 45 0 and vertical position by α= 900). The space between turbulators was fixed by distributing 5 pieces of these turbulators with pitch ratio    PR = (0.44). Also, the factor of constant heat flux was applied as a boundary condition around the tube test section for all experiments of this investigation, while the flow rates were selected as a variable factor (Reynolds number values vary from 5000 to 15000). The results s

... Show More
View Publication Preview PDF
Crossref (3)
Crossref