Preferred Language
Articles
/
bijps-1421
Adherence to Different Treatment Modalities among Patients on Maintenance Hemodialysis
...Show More Authors

        End Stage Renal Disease is a well-known global public health problem. Maintenance hemodialysis is considered a life-saving treatment for patients with such disease. This treatment method that requires patients to be adherent to hemodialysis attendance, dietary and fluid recommendations as well as adherence to prescribed medications to ensure success. The aim of the current study was to assess adherence, perception, and counseling among hemodialysis patients to different modalities of treatment (fluid restriction, dietary recommendations, medications, and hemodialysis schedules). A cross-sectional study carried out on hemodialysis patients who attended to the dialysis centers at al- Karama teaching hospital and Madinat Al- Imamain Al- Kadhimain teaching hospital. The  Arabic version  of the “ end stage renal disease-adherence questionnaire ” was used in assessing adherence, perception, and counseling. The number of recruited patients were 200 adult patients (113 men and 87 women). The average of the total adherence score lies within the moderate adherence (984.9 ±174.2). Patients adherence to the hemodialysis session was good as representing by high scores of adherence for (hemodialysis-attendance, episode of hemodialysis-shortening and duration of hemodialysis-shortening) while the lowest adherence score (126.0 out of 200) was for following the fluid restriction. In terms of adherence categories, the majority (61%) of the patients had good adherence, 33.0% had moderate adherence with 6% had poor adherence. Age had significant positive association with the total adherence score. All patients perceived their hemodialysis management as highly/very important. On the other hand, some patients perceived their adherence to the recommended diet as moderately (7%) or less important (7%). Regarding the frequency of counseling received by patients for different treatment modalities.  The negative answers represented 58.5% of answers about the how important is to follow a proper diet, and 25.0% of answers about the importance of taking prescribed medications as ordered. Accordingly, the overall adherence of hemodialysis patients to different treatment modalities was less than optimum with fluid and diet adherence representing most challenging tasks in the health care of hemodialysis patients.  

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Jun 16 2023
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Preparation and in Vitro Evaluation for Different Types of Ondansetron Hydrochloride Transdermal Patches
...Show More Authors

This research aims to develop transdermal patches of Ondansetron hydrochloride (OSH) with different types of polymers, ethyl cellulose and, polyvinyl pyrrolidone k30 in a ratio (3:0.5,3:1,3:2,2:1,1:1) with propylene glycol 20%w/w as a plasticizer. Prepared transdermal patches were evaluated for physical properties. The compatibility between the drug and excipients was studied by Differential scanning calorimetry (DSC), where there is no interaction between the drug and polymers. From the statistical study, there is a statistical difference between all the prepared formulations p<0.05. In-vitro Release study of transdermal patches was performed by using a paddle over the disc. The release profile of OSH follow

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Sat Oct 01 2011
Journal Name
Journal Of Engineering
THERMAL BUCKLING OF RECTANGULAR PLATES WITH DIFFERENT TEMPERATURE DISTRIBUTION USING STRAIN ENERGY METHOD
...Show More Authors

By using governing differential equation and the Rayleigh-Ritz method of minimizing the total potential energy of a thermoelastic structural system of isotropic thermoelastic thin plates, thermal buckling equations were established for rectangular plate with different fixing edge conditions and with different aspect ratio. The strain energy stored in a plate element due to bending, mid-plane thermal force and thermal bending was obtained. Three types of thermal distribution have been considered these are: uniform temperature, linear distribution and non-linear thermal distribution across thickness. It is observed that the buckling strength enhanced considerably by additional clamping of edges. Also, the thermal buckling temperatures and

... Show More
View Publication Preview PDF
Crossref (6)
Crossref
Publication Date
Wed Mar 25 2020
Journal Name
International Journal Of Drug Delivery Technology
Study of Molecular Interaction for Antibiotic Drug with Sugar Solutions at Different Temperature
...Show More Authors

The interactions of drug amoxicillin with maltose or galactose solutions with a variation of temperature have been discussed by taking in the volumetric and viscometric procedures. Physical properties [densities (ρ) and viscosities (η)] of amoxicillin (AMOX) aqueous solutions and aqueous solutions of two type saccharides (maltose and galactose 0.05m) have been measured at T = (298.15, 303.15 and 308.15) K under atmospheric pressure. The apparent molar volume (ϕv cm3mole-1) has been evaluated from density data and fitted to a Redlich-Mayer equation. The empirical parameters of the Mayer-Redlich equation and apparent molar volume at infinite dilution ذv were explicated in terms of interactions from type solute-solvent and solute

... Show More
View Publication
Scopus (4)
Crossref (3)
Scopus Crossref
Publication Date
Fri Jan 01 2016
Journal Name
Journal Of Engineering
Thermal Characteristics of Closed Wet Cooling Tower Using Different Heat Exchanger Tubes Arrangement
...Show More Authors

This paper presents thermal characteristics analysis of a modified Closed Wet Cooling Tower (CWCT) based on heat and mass transfer principles to improve the performance of this tower in Iraq. A prototype of CWCT optimized by added packing was designed, manufactured and tested for cooling capacity of 9 kW. Experiments are conducted to explore the effects of various operational and conformational parameters on the thermal performance. In the test section, spray water temperature and both dry bulb temperature and relative humidity of the air measured at intermediate points of the heat exchanger and packing. Heat exchangers consist of four rows and eight columns for an inline tubes arrangement and six rows and five columns f

... Show More
View Publication Preview PDF
Publication Date
Tue Aug 01 2023
Journal Name
Electric Power Systems Research
Optimal design of high voltage composite insulators with grading rings in different configurations
...Show More Authors

View Publication
Scopus (21)
Crossref (19)
Scopus Clarivate Crossref
Publication Date
Sat Mar 28 2020
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Different Electrodes Connections in Electrocoagulation of Synthetic Blow down Water of Cooling Tower
...Show More Authors

In this research, the performance of electrocoagulation (EC) using aluminum (Al) electrodes with   Monopolar- parallel (MP-P), and bipolar - series (BP-S) arrangement for simultaneous removal of dissolved silica, and hardness ions (calcium, and magnesium) from synthetic blowdown water of cooling tower were investigated. The effects of current density, initial pH and time of electrolysis on the removal efficiency were studied in a batch stirred unit to find out the best-operating conditions. The obtained results for each target species are evidence that BP-S approach is the best for both electrodes configuration operated at a Current density of 1mA/cm2 through 30 min of treatment and pH=10 with the removal of

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of Engineering
Serviceability of Post-fire RC Rafters with Openings of Different Sizes and Shapes
...Show More Authors

This study deals with the serviceability of reinforced concrete solid and perforated rafters with openings of different shapes and sizes based on an experimental study that includes 12 post-fire non-prismatic reinforced concrete beams (solid and perforated). Three groups were formed based on heating temperature (room temperature, 400 °C, and 700 °C), each group consisting of four rafters (solid, rafters with 6 and 8 trapezoidal openings, and rafter with eight circular openings) under static loading. A developed unified calculation technique for deflection and crack widths under static loading at the service stage has been provided, which comprises non-prismatic beams with or without opening exposed to flexure concentra

... Show More
View Publication Preview PDF
Crossref (8)
Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Aip Conference Proceedings
Nonlinear optical properties of liquid crystal doped with different concentrations of carbon nanotubes
...Show More Authors

View Publication
Scopus (7)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Tue Feb 01 2022
Journal Name
Journal Of Engineering
Permanent Deformation Characterization of Stone Matrix Asphalt Reinforced by Different Types of Fibers
...Show More Authors

This paper focused on the stone matrix asphalt (SMA) technology that was developed essentially to guard against rutting distress. For this procedure, fibers play a racy role in stabilizing and preventing the drain down problem caused by the necessity of high binder content coupled with their strengthening effect. A set of specimens with cylindrical and slab shapes were fabricated by inclusions jute, polyester, and carbon fibers. For each type, three contents of 0.25%, 0.5%, and 0.75% by weight of mixture were added by lengths of 5, 7.5, and 10 mm. The prepared mixtures were tested to gain the essential pertained parameters discriminated by the values of drain down, Marshall quotient, rut depth, and dynamic stability. It

... Show More
View Publication Preview PDF
Crossref (18)
Crossref
Publication Date
Wed Apr 27 2022
Journal Name
Arabian Journal For Science And Engineering
Optical and Thermal Performance of a Parabolic Trough Collector for Different Receiver Geometries
...Show More Authors

This paper numerically and theoretically investigates the optical and thermal performance of a parabolic trough collector PTC system. Many numerical simulations and theoretical analyses are conducted to demonstrate the influence of the receiver geometry and shifting from the focal position on the optical performance. The examined receiver geometries are circular, square, triangular, elliptical, and the new circular–square combined geometry is named as channel receiver. The thermal performance of PTC is examined for different volume flow rates theoretically in the range of (0.36 to 2.4 lpm). The results show that the best optical design is the channel receiver with an intercept factor of 84%, while the worst is the elliptical receiver with

... Show More
View Publication
Scopus (17)
Crossref (9)
Scopus Crossref