The experiment aimed to Manufacture a device for checking the nozzles and testing its efficiency and to study the effect of research factors on the studied traits. The device was manufactured locally through using materials available in the Iraqi market. The system is Both Hydraulic and electronic (ISO 5682-1)1 relay on sensors technology and the test platform was built and designed on a movable trolly at the department of Agricultural Machines and Equipment / College of Agricultural Science / University of Baghdad. The design includes the use of mechanical water pump and electrical AC water pump. The design includes a nozzle holder that can accommodate three nozzles per test. The design also consists of spreading wings and stationary wing that can accommodate 50 vessels and 50 ultra-sonic sensors. All that is controlled by a main control unit which consists of three branch modules (each one of them is responsible to collect and analyze data from several sensors on each of the wings. The idea behind the design is to merge between actual spraying and the use of electronic sensors to analyze the size of the sprayed liquid in each of the vessels, the concept of the design is based upon Volumetric distribution of the liquid. The concept of the device was based on using ultra sonic sensors to measure the volumetric distribution of liquids. The experiment aimed to determine the effects of these factors on flow rate, spraying angle, sprayed area, spraying swath, volumetric distribution (CV), and symmetry. The experiment was conducted at the college of Agricultural science, Baghdad University. The results showed that the spraying pressure had a non-significant effect on flow rate. However, increasing the pressure from 3.0 to 5.0 and then to 7.0 bar resulted in flow rates of 1.314, 1.286, and 1.36 l/m, respectively. The status of the nozzle (new or worn) did not significantly affect the flow rate, with new nozzles registering a slightly higher flow rate of 1.327 l/m compared to worn nozzles (1.312 l/m). On the other hand, the type of nozzle had a significant impact on flow rate, with plastic, brass, and steel nozzles registering flow rates of 1.243, 1.422, and 1.29 l/m, respectively. Regarding the spraying angle, the results indicated that the spraying pressure had a significant effect. Increasing the pressure from 3.0 to 5.0 and then to 7.0 bar resulted in spraying angles of 132, 132, and 136 degrees, respectively. The nozzle status significantly affected the spraying angle, with worn nozzles resulting in a higher angle of 137 degrees compared to new nozzles (130 degrees). However, the type of nozzle did not significantly affect the spraying angle. For the sprayed area, the spraying pressure had a significant effect, with higher pressures resulting in larger sprayed areas. Worn nozzles also significantly increased the sprayed area compared to new nozzles. The type of nozzle had a significant impact on the sprayed area, with plastic, brass, and steel nozzles resulting in areas of 70.4, 80.44, and 89.16 cm2, respectively. The experiment proved that nozzles must be tested periodically, otherwise they start to perform beyond the parameters they were designed to perform with.
The problem of the study and its significance:
Due to the increasing pressures of life continually, and constant quest behind materialism necessary and frustrations that confront us daily in general, the greater the emergence of a number of cases of disease organic roots psychological causing them because of severity of a lack of response to conventional treatments (drugs), and this is creating in patients a number of emotional disorders resulting from concern the risk of disease
That is interested psychologists and doctors searchin
... Show MoreCharacterization of the heterogonous reservoir is complex representation and evaluation of petrophysical properties and application of the relationships between porosity-permeability within the framework of hydraulic flow units is used to estimate permeability in un-cored wells. Techniques of flow unit or hydraulic flow unit (HFU) divided the reservoir into zones laterally and vertically which can be managed and control fluid flow within flow unit and considerably is entirely different with other flow units through reservoir. Each flow unit can be distinguished by applying the relationships of flow zone indicator (FZI) method. Supporting the relationship between porosity and permeability by using flow zone indictor is ca
... Show MoreThe present study aims to detection optimal conditions of production of amylase enzyme from isolate of B. subtillis A4. Nine carbonic sources were represented by starch, maltose, fructose, sucrose, glucose, arabinose, xylose, sorbitol and mannitol) at concentration of 1% for each source. It was found that the best was represented by starch carbonic, which showed higher activity and qualitative activity of 7.647 Unit/ ml and 461.56 Unit/ mg. Ten nitrogen sources were selected, including yeast extract, peptone, trypton, gelatin, urea and meat extract as organic sources Ammonium sulphate, Sodium nitrate, Potassium nitrate and Ammonium chloride as inorganic sources. These sources were added at aconcentration of 0.5% to the production medium. Th
... Show MoreThis experiment was carried out at the Grdarash field belongs to the Agricultural researches directorate/general Agriculture directorate-Erbil in September (2007)، 27 Arabic lambs aged (5-6 months) With average initial weight (39.178 Kg/lamb) were used. Lambs were divided in to (3) groups (9 lambs/group). Control group was fed on (85% barely، 10% bran and 5% straw)، and second and third groups were fed on various by-product in replacement with barely in loss and block shape respectively.
The total gain of three groups were (392708.32، 634826.52 & 445613.72 ID resp
... Show Moreجريت التجربة في اصص فخارية سعة كل اصيص 4 كغم تربة في البيت الزجاجي التابع لقسم علوم الحياة/كلية التربية ابن الهيثـــــــــم/جـامعــة بـغداد لموســم النمـو 2008-2009 لدراســة تأثيــر اربعـــة مستويـــــات من سمــــاد اليوريـــا وهي (0, 0.1, 0.2, 0.4) غم/اصيص والتي تعادل (0, 100, 200, 400) كغم/هكتار وثلاث مستويات من سماد السوبر فوسفات وهي (0, 0.1, 0.2) غم/اصيص والتي تعادل (0, 100, 200) كغم/هكتارفي مكونـات الحاصـــل لنبــات الحلبـــة Trigonella foe
... Show MoreBackground: Elastomeric chains are one of the most commonly used force delivery systems. They have the ability to exert a continuous force, convenience of use, compatibility to oral environment and cost effectiveness but one of the inherited disadvantages is force degradation. Materials and methods: This in vitro study was designed to evaluate the effect of alcohol presence in mouthwashes on force decay of different configurations of clear elastomeric chains from (Ortho Technology company) which are: closed , short and long under the effect of time at (Initial, 1, 2, 3 and 4 weeks) intervals with exposure to different chemical solutions. A total (540) modules of elastomeric chains of three different types (long, short and closed) trans
... Show MoreBackground: Women sexuality is basic right and it plays a major role in women's Health aspects. Up is one of the factors that lead to sexual dysfunction while the incidence of it is rising as UP severity being more. Objectives: To assess the impact of different degrees of uterine prolapse on sexual function of women at teaching hospitals in AL-Hilla City. Methodology: A descriptive analytical study was conducted from 1ST Feb to 10th Jun /2014 to assess the impact of different degrees of uterine prolapse on sexual function for women who attend to consultant clinic at teaching hospitals in AL-Hilla City
Objective: Evaluate the effects of different storage periods on flexural strength (FS) and degree of conversion (DC) of Bis-Acryl composite and Urethane dimethacrylate provisional restorative materials. Material and Methods: A total of 60 specimens were prepared from four temporary crown materials commercially available and assigned to four tested groups (n = 15 for each group): Prevision Temp, B&E CROWN, Primma Art, and Charm Temp groups. The specimens were stored in artificial saliva, and the FS was tested after 24 h, 7 d, and 14 d. A standard three-point bending test was conducted using a universal testing machine. Additionally, the DC was determined using a Fourier transform infrared spectroscopy (FTIR) device. The data were analyzed st
... Show More