The experiment aimed to Manufacture a device for checking the nozzles and testing its efficiency and to study the effect of research factors on the studied traits. The device was manufactured locally through using materials available in the Iraqi market. The system is Both Hydraulic and electronic (ISO 5682-1)1 relay on sensors technology and the test platform was built and designed on a movable trolly at the department of Agricultural Machines and Equipment / College of Agricultural Science / University of Baghdad. The design includes the use of mechanical water pump and electrical AC water pump. The design includes a nozzle holder that can accommodate three nozzles per test. The design also consists of spreading wings and stationary wing that can accommodate 50 vessels and 50 ultra-sonic sensors. All that is controlled by a main control unit which consists of three branch modules (each one of them is responsible to collect and analyze data from several sensors on each of the wings. The idea behind the design is to merge between actual spraying and the use of electronic sensors to analyze the size of the sprayed liquid in each of the vessels, the concept of the design is based upon Volumetric distribution of the liquid. The concept of the device was based on using ultra sonic sensors to measure the volumetric distribution of liquids. The experiment aimed to determine the effects of these factors on flow rate, spraying angle, sprayed area, spraying swath, volumetric distribution (CV), and symmetry. The experiment was conducted at the college of Agricultural science, Baghdad University. The results showed that the spraying pressure had a non-significant effect on flow rate. However, increasing the pressure from 3.0 to 5.0 and then to 7.0 bar resulted in flow rates of 1.314, 1.286, and 1.36 l/m, respectively. The status of the nozzle (new or worn) did not significantly affect the flow rate, with new nozzles registering a slightly higher flow rate of 1.327 l/m compared to worn nozzles (1.312 l/m). On the other hand, the type of nozzle had a significant impact on flow rate, with plastic, brass, and steel nozzles registering flow rates of 1.243, 1.422, and 1.29 l/m, respectively. Regarding the spraying angle, the results indicated that the spraying pressure had a significant effect. Increasing the pressure from 3.0 to 5.0 and then to 7.0 bar resulted in spraying angles of 132, 132, and 136 degrees, respectively. The nozzle status significantly affected the spraying angle, with worn nozzles resulting in a higher angle of 137 degrees compared to new nozzles (130 degrees). However, the type of nozzle did not significantly affect the spraying angle. For the sprayed area, the spraying pressure had a significant effect, with higher pressures resulting in larger sprayed areas. Worn nozzles also significantly increased the sprayed area compared to new nozzles. The type of nozzle had a significant impact on the sprayed area, with plastic, brass, and steel nozzles resulting in areas of 70.4, 80.44, and 89.16 cm2, respectively. The experiment proved that nozzles must be tested periodically, otherwise they start to perform beyond the parameters they were designed to perform with.
Albizia lebbeck biomass was used as an adsorbent material in the present study to remove methyl red dye from an aqueous solution. A central composite rotatable design model was used to predict the dye removal efficiency. The optimization was accomplished under a temperature and mixing control system (37?C) with different particle size of 300 and 600 ?m. Highest adsorption efficiencies were obtained at lower dye concentrations and lower weight of adsorbent. The adsorption time, more than 48 h, was found to have a negative effect on the removal efficiency due to secondary metabolites compounds. However, the adsorption time was found to have a positive effect at high dye concentrations and high adsorbent weight. The colour removal effi
... Show MoreA field experiment was carried out during the 2020 season at the College of Agricultural Engineering/ University of Baghdad, Al-Jadriya to evaluate the effect of dry farming when applying water stress under the subsurface drip irrigation system on water productivity and rice yield. The experiment was conducted with three levels of irrigation water stress when 10, 20 and 40% of the available water was depleted and in three dimensions between drip lines 10, 15 and 20 cm. The experiment was designed according to a randomized complete block design, according to the split plot design, with three replications. Determine the depth of irrigation water depending on the moisture depletion of th
Dynamic machine foundations can be considered as a necessary component of the industrial infrastructure. Design of the dynamic equipment foundations has, however, traditionally been grounded on a rule of thumb that is inaccurate and rigid to use at the discretion of the engineers. The conventional rule of thumb, which includes minimum weight ratios and resonance avoidance criteria, has been used singularly with two poles, which can be either conservatively designed systems that are too heavy, or systems that are going to experience too much vibration and fatigue. This paper presents a novel, analytical framework for the reinterpretation of traditional design practices, using a physics-based approach, and results in a single, unified overall
... Show MoreDue to the urgent need to develop technologies for continuous glucose monitoring in diabetes individuals, poten tial research has been applied by invoking the microwave tech niques. Therefore, this work presents a novel technique based on a single port microwave circuit, antenna structure, based on Metamaterial (MTM) transmission line defected patch for sensing the blood glucose level in noninvasive process. For that, the proposed antenna is invoked to measure the blood glu cose through the field leakages penetrated to the human blood through the skin. The proposed sensor is constructed from a closed loop connected to an interdigital capacitor to magnify the electric field fringing at the patch center. The proposed an tenna sensor i
... Show MoreFreshwater scarcity poses a global challenge, particularly in regions where conventional water resources are limited. Solar stills offer an economical, sustainable solution; however, their yield is limited. This study aims to evaluate a new tracking concentrated tilted tubular solar still equipped with a heat‐pipe TTSS‐HP. The novelty of the present work lies in four aspects: a novel trough U‐channel design that improves the interception of reflected solar radiation, a novel hexagonal glass cover design. A receiver formed of four‐sections, combined with a heat‐pipe and dual trough concentrators. Outdoor experiments are carried out in Baghdad, Iraq (33.27° N, 44.37° E),
The study involved the synthesis of new complexes with tetradentate ligand (LH). The general formula of complexes was [M(LH)(H2O)2] with M of Ni2+, Co2+, Cu2+, and Zn+. The ligand was synthesized by treating the 2-hydroxybenzohydrazide with salicylaldehyde. The structural characteristics of ligands and complexes were analyzed using various techniques, including elemental analyses, magnetic susceptibility, molar conductivity, infrared, ultraviolet absorption, mass, and NMR spectroscopy studies. The physical measurements indicated that the prepared complexes are non-electrolyte and showed that the ligand is tetradentate when coordinated with metal ions through the nitrogen of azomethine (–C=N–), two oxygen atoms of O–H phenolic,
... Show MoreIn this study, the new azo dye,5,5-[1,2-phenylenebis(2,1-biazenediyl)] bis[8-quinolino], was used to synthesize complexes with Co2+, Ni2+, Cu2+, Zn2+, and Cd2+ ions. The compounds were characterized using 1H and 13C nuclear magnetic resonance (NMR) spectroscopy, Fourier transform infrared (FT-IR) spectroscopy, ultraviolet-visible (UV-Vis) spectroscopy, mass spectrometry, thermo gravimetric analysis (TGA), diffevential scanning calovimltry (DSC), CHN analysis. Further, conductivity, magnetic susceptibility, and metal and chlorine content analysis using FT-IR spectroscopy revealed that the ligand chelates as a bidentate (OH) phenol group and a bidentate (C=N) ring group. The ligand exhibited tetradentate behavior, forming tetrahedral complexe
... Show More