The experiment aimed to Manufacture a device for checking the nozzles and testing its efficiency and to study the effect of research factors on the studied traits. The device was manufactured locally through using materials available in the Iraqi market. The system is Both Hydraulic and electronic (ISO 5682-1)1 relay on sensors technology and the test platform was built and designed on a movable trolly at the department of Agricultural Machines and Equipment / College of Agricultural Science / University of Baghdad. The design includes the use of mechanical water pump and electrical AC water pump. The design includes a nozzle holder that can accommodate three nozzles per test. The design also consists of spreading wings and stationary wing that can accommodate 50 vessels and 50 ultra-sonic sensors. All that is controlled by a main control unit which consists of three branch modules (each one of them is responsible to collect and analyze data from several sensors on each of the wings. The idea behind the design is to merge between actual spraying and the use of electronic sensors to analyze the size of the sprayed liquid in each of the vessels, the concept of the design is based upon Volumetric distribution of the liquid. The concept of the device was based on using ultra sonic sensors to measure the volumetric distribution of liquids. The experiment aimed to determine the effects of these factors on flow rate, spraying angle, sprayed area, spraying swath, volumetric distribution (CV), and symmetry. The experiment was conducted at the college of Agricultural science, Baghdad University. The results showed that the spraying pressure had a non-significant effect on flow rate. However, increasing the pressure from 3.0 to 5.0 and then to 7.0 bar resulted in flow rates of 1.314, 1.286, and 1.36 l/m, respectively. The status of the nozzle (new or worn) did not significantly affect the flow rate, with new nozzles registering a slightly higher flow rate of 1.327 l/m compared to worn nozzles (1.312 l/m). On the other hand, the type of nozzle had a significant impact on flow rate, with plastic, brass, and steel nozzles registering flow rates of 1.243, 1.422, and 1.29 l/m, respectively. Regarding the spraying angle, the results indicated that the spraying pressure had a significant effect. Increasing the pressure from 3.0 to 5.0 and then to 7.0 bar resulted in spraying angles of 132, 132, and 136 degrees, respectively. The nozzle status significantly affected the spraying angle, with worn nozzles resulting in a higher angle of 137 degrees compared to new nozzles (130 degrees). However, the type of nozzle did not significantly affect the spraying angle. For the sprayed area, the spraying pressure had a significant effect, with higher pressures resulting in larger sprayed areas. Worn nozzles also significantly increased the sprayed area compared to new nozzles. The type of nozzle had a significant impact on the sprayed area, with plastic, brass, and steel nozzles resulting in areas of 70.4, 80.44, and 89.16 cm2, respectively. The experiment proved that nozzles must be tested periodically, otherwise they start to perform beyond the parameters they were designed to perform with.
The H-Point Standard Addition Method (H-PSAM) has been applied for spectrophotometric simultaneous determination of Cimetidine and Erythromycin ethylsuccinate using Bromothymol Blue (BTB) as a chromogenic complexing agent in a buffer solution at pH 5.5.
The research discusses one of the most critical issues of corporate finance which is related to asset utilization efficiency. Researchers used internal growth rate as independent variable (Proxy of asset utilization efficiency) and sustainable growth rate-dependent variable (proxy of stockholders wealth). According to these two variables, researchers formulate major hypotheses (There is no significant effect of internal growth rate on sustainable growth rate), as well as two sub-hypotheses, examine the components of major variables. Sample of Iraqi industrial companies which listed in the Iraqi stock exchange selected to test and examine main hypotheses. Result of simple and multiple regressions explain there is a significant effect of i
... Show MoreIn the current work, the mixing ratios ( 𝛿 ) of gamma transitions were calculated from energy levels in the isotopes neodymium 60𝑁𝑎 142−150 populated in the 60Nd 142− 150 (n, n ˊγ) 60Nd 142− 150 using the 𝑎2 ratio method. We used the experimental coefficient (𝑎2 ) for two γ-transitions from the initial state itself, the statistical tensor 𝜌2(𝐽𝑖), associated with factor 𝑎2 , would be the same for the two transitions. The results obtained are in good agreement or within the experimental error with -those previously published. And existing contradictions resulting from inaccuracies in the empirical results of previous work. The current results confirm that the , 𝑎2 − method is used to calculate th
... Show MoreA novel Schiff base ligand (DBC) synthesized from 4-chlorobenzoic acid, along with its Cu (II) and Co (II) complexes, was prepared and characterized using FT-IR, 1H and 13C-NMR, UV-Vis spectroscopy, as well as magnetic and conductivity measurements. Based on this, a tetrahedral structure of [M(DBC)Cl2] was proposed for the complexes. Antioxidant activity of the compounds was assessed and compared to ascorbic acid, revealing that the copper complex exhibited superior antioxidant properties compared to the cobalt complex and the ligand. Furthermore, the antibiofilm potential of the copper and cobalt complexes was assessed against five clinically relevant bacterial species (P.aeruginosa, E.coli, K.pneumoniae, S.aureus and S.typhi) usin
... Show MoreBackground: The gene encoding a disintegrin and metalloproteinase domain 33 (ADAM33) is known to be associated with asthma in different ethnic groups. In Iraq, among the Arab ethnic background, this association has not yet been highlighted. Methods: One hundred and ninety-two asthmatics were examined; 118 males and 74 females (mean age 38.23 ± 9.13 years). The control group was 183; 110 males and the rest were females. The SNP of rs2280091 A/G (T1) was studied here to determine adam33 genotyping status using polymerase chain reaction–restriction fragment length polymorphism (PCR–RFLP). The level of total IgE was measured using enzyme-linked immunosorbent assay (ELISA). Results: Significant differences (p = 0.004) in the frequencies of
... Show MoreThis paper presents a comparison study on thermal performance conic cut twist tape inserts in laminar flow of nanofluids through a constant heat fluxed tube. Three tape configurations, namely, quadrant cut twisted tape (QCT), parabolic half cut twisted tape (PCT), and triangular cut twisted (VCT) of twist ratio= 2.93 and cut depth= 0.5 cm were used with 1% and 2% volume concentration of SiO2/water and TiO
... Show MoreThis study investigated the prevalence of quinolones resistance proteins encoding genes (qnr genes) and co-resistance for fluoroquinolones and β-lactams among clinical isolates of Klebsiella pneumoniae. Out of 150 clinical samples, 50 isolates of K. pneumoniae were identified according to morphological and biochemical properties. These isolates were collected from different clinical samples, including 15 (30%) urine, 12 (24%) blood, 9 (18%) sputum, 9 (18%) wound, and 5 (10%) burn. The minimum inhibitory concentrations (MICs) assay revealed that 15 (30%) of isolates were resistant to ciprofloxacin (≥4µg/ml), 11 (22%) of isolates were resistant to levofloxacin (≥8 µg/ml), 21 (42%) of isolates were re
... Show MoreThe removal of heavy metal ions from wastewater by ion exchange resins ( zeolite and purolite C105), was investigated. The adsorption process, which is pH dependent, shows maximum removal of metal ions at pH 6 and 7 for zeolite and purolite C105 for initial metal ion
concentrations of 50-250 mg/l, with resin dose of 0.25-3 g. The maximum ion exchange capacity was found to be 9.74, 9.23 and 9.71 mg/g for Cu2+, Pb2+, and Ni2+ on zeolite respectively, while on purolite C105 the maximum ion exchange capacity was found to be 9.64 ,8.73 and 9.39 for Cu2+, Pb2+, and Ni2+ respectively. The maximum removal was 97-98% for Cu2+ and Ni2+ and 92- 93% for Pb2+ on zeolite, while it was 93-94% for Cu2+, 96-97% for Ni2+, and 87-88% for Pb2+ on puroli