The aim of this study is to investigate the kinetics of copper removal from aqueous solutions using an electromembrane extraction (EME) system. To achieve this, a unique electrochemical cell design was adopted comprising two glass chambers, a supported liquid membrane (SLM), a graphite anode, and a stainless-steel cathode. The SLM consisted of a polypropylene flat membrane infused with 1-octanol as a solvent and bis(2-ethylhexyl) phosphate (DEHP) as a carrier. The impact of various factors on the kinetics constant rate was outlined, including the applied voltage, initial pH of the donor phase solution, and initial copper concentration. The results demonstrated a significant influence of the applied voltage on enhancing the rate of c
... Show MoreThe research investigates the term innovation and its role in elaborating architectural practice based on diffusion. The complexity of the architectural field compared with other fields shows a problem in explaining how innovations in architecture diffuse as a thought and act in a certain context of practice. Therefore, the research aims to build an intellectual model that explains the way personal thoughts resembled by unique models introduced by creative and innovator designers diffuse in a certain pattern elaborate these models into a state of prevailing thought resembled by the movement in architecture. The research will apply its model to the more comprehensive movement in architecture, which is the modern movement,
... Show MoreBackground: Chronic suppurative otitis media (CSOM) is the result of an initial episode of acute otitis media and is characterized by a persistent discharge from the middle ear through a tympanic perforation for at least 2 weeks duration. It is an important cause of preventable hearing loss, particularly in the developing world.Objective: To get an overview on the bacterial ear infection profile in general and to assess the antibiotic resistance of Pseudomonal infection (PS) particularly since it is usually the commonest infection to cause otitis media and the most difficult to treat due to the problem of multi drug resistance..Methods: A cross sectional study was done which included 405 patients of CSOM patients, 196 (48%) case were mal
... Show MoreBackground: Chronic suppurative otitis media (CSOM) is the result of aninitial episode of acute otitis media and is characterized by a persistent discharge from the middle ear through a tympanic perforation for at least 2 weeks duration. It is an important cause of preventable hearing loss, particularly in the developing world.Methods. 1. To get an overview on the bacterial ear infection profile in general 2. To assess the antibiotic resistance of Pseudomonal infection (PS) particularly since it is usually the commonest infection to cause otitis media and the most difficult to treat due to the problem of multi drug resistance... A cross sectional study was done which included 405 patient of CSOM patients196 (48%) case were males ,209 (52
... Show MoreThe term "nano gold," also known as "gold nanoparticles," is commonly used. These particles are extremely small, with a diameter of less than 100 nm, which is only a fraction of the width of a human hair. Due to their tiny size, nano gold particles are often found in a colloidal solution, where they are suspended in a liquid stabilizer. This colloidal gold is essentially another name for nano gold. The main method for producing gold nanoparticles in a colloidal solution is the citrate synthesis technique, which involves combining different solutions to precipitate the gold nanoparticles. In biological systems, copper complexes play a significant role at the active sites of many metalloproteins. These complexes have potential applications in
... Show MoreABSTRACT Background: According to Branemark’s protocol, the waiting period between tooth extraction and implant placement is 6–8 months; this is the late placement technique. Achieving and maintaining implant stability are prerequisites for a dental implant to be successful. Resonance Frequency Analysis (RFA) is a noninvasive diagnostic method that measures implant stability. The aim of this study was to investigate the influence of treatment protocol and implant dimensions on primary implant stability utilizing RFA. Materials and methods: This study included 63 Iraqi patients (37 male, 26 female; ranging 22-66 years). According to treatment protocol, the sample was divided into 2 groups; A (delayed) & B (immediate). Dental im
... Show MoreIn this research, rabbit femurs were implanted with CP Ti screws coated with a combination of CaCO3 and nanohydroxyapatite, and the effect on osseointegration was assessed using histological and histomorphometric examination at 2 and 6 weeks. CaCO3 and nanohydroxyapatite were combined with the EPD to coat the surfaces of the CP Ti screws. The femurs of five male rabbits were implanted with coated and uncoated implant screws. Healing time was divided into two groups (2 and 6 weeks). After 2 and 6 weeks of implantation, the histological examination revealed an increase in the growth of bone cells for coated screws, and the histomorphometric analysis revealed an increase in the percentage of ne
... Show MorePolyetheretherketone (PEEK) has favorable biomechanical properties to be used as an implant material. Unfortunately, it is hydrophobic and does not promote cellular adhesion, which could result in poor integration with bone tissue. Bio-functionalization of PEEK surface with osteogenic peptides derived from bone extracellular matrix proteins is an exciting approach to encourage bone formation around the implant. In the current study, bone-forming peptide-2 was immobilized on PEEK surface using two different methods, using dopamine and a diglycidyl ether as conjugate compounds, respectively. Peptide quantification test revealed that the two strategies resulted in the most amount of peptides were attached with 0.5 mM concentration and no furth
... Show MoreAbstract
Stainless steel (AISI 304) has good electrical and thermal conductivities, good corrosion resistance at ambient temperature, apart from these it is cheap and abundantly available; but has good mechanical properties such as hardness. To improve the hardness and corrosion resistance of stainless steel its surface can be modified by developing nanocomposite coatings applied on its surface. The main objective of this paper is to study effect of electroco-deposition method on microhardness and corrosion resistance of stainless steel, and to analyze effect of nanoparticles (Al2O3, ZrO2 , and SiC) on properties of composite coatings. I
... Show More