Preferred Language
Articles
/
bRbnQYcBVTCNdQwC0D5W
An in vitro investigation into retention strength and fatigue resistance of various designs of tooth/implant supported overdentures
...Show More Authors

Crossref
View Publication
Publication Date
Sun Sep 27 2026
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of smear layer on push-out bond strength to dentin of Bioceramic sealer (In vitro study)
...Show More Authors

Background: Sealers should demonstrate adhesive properties to dentin, decreasing the chance of endodontic treatment failure. Increased adhesive properties to dentin may lead to greater strength of the restored tooth, which may provide greater resistance to tooth fracture and clinical longevity of an endodontically treated tooth. The aim of this study was to evaluate the shear bond strength of Bioceramic iRoot SP sealer, AH plus sealer and Apexit plus sealer in absence or presence of smear layer using push out bond strength test. Materials and Methods: Sixty straight single roots of the mandibular premolars were selected for this study. All canals were instrumented using ProTaper rotary instruments to achieve tapered canal walls, instrumenta

... Show More
View Publication Preview PDF
Publication Date
Sun Sep 27 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Comparison between powerful Waterpik flosser with dental floss as an adjunct to tooth brushing
...Show More Authors

Background: Removing dental plaque is important to maintain a good oral hygiene and prevent periodontal disease; this could not be accomplished by the use of toothbrush alone, it needs the help of interdental aids or intra-oral irrigator devices. The aim of this study was to compare the effect of using Waterpik flosser as adjunct to tooth brushing than using the dental floss with the brushing. Materials and methods: A single blind, six weeks study included 45 subjects divided into three groups of 15 subjects at each group. Group B (brushing) was instructed to use the toothbrush only, group BF (brushing & flossing) was instructed to use dental floss and tooth brushing while group BW (brushing and Waterpik flosser) was instructed to use Water

... Show More
View Publication Preview PDF
Publication Date
Thu Feb 01 2024
Journal Name
Journal Of Orthodontic Science
Antimicrobial behavior of nanocoated orthodontic micro-implants: An in vitro study
...Show More Authors
OBJECTIVE:

The need to overcome the failure of orthodontic micro-implants which might reach to 30% has led to the development of different methods, one of which is nanoparticle deposition.

AIM OF STUDY:

To evaluate the anti-microbial efficiency of TiO2 and ZnO nanoparticles (NP) when used as a coating for orthodontic micro-implants.

METHODS:

Thirty titanium alloy micro-implants were used in the presented study. They were divided into three

... Show More
View Publication
Scopus (6)
Crossref (5)
Scopus Crossref
Publication Date
Thu Mar 30 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
An Investigation Release and Rheological Properties of Miconazole Nitrate from Emulgel
...Show More Authors

         In this study miconazole nitrate was formulated as topically applied emulgel; different formulas were prepared using sodium carboxymethylcellulose (SCMC) and carboxypolymethylene (carbomer 941) as gelling agents. The influence of type of gelling agent and concentration of both oil phase and emulsifying agent on drug release was studied and compared with commercially available miconazole nitrate cream (Mecozalen®). The results of in vitro release showed that SCMC emulgel bases gave better release than carbomer 941 bases and the release of drug increase from both bases as a function of increasing the concentration of emulisifying agent. The oil phase had retardation effect when

... Show More
View Publication Preview PDF
Crossref (7)
Crossref
Publication Date
Wed Nov 05 2025
Journal Name
Journal Of Oral Biology And Craniofacial Research
The effect of thermocycling on fracture resistance of zirconia crowns cemented with polylysine modified resin cements (Comparative in vitro study)
...Show More Authors

ABSTRACT Background: resin cement type and intraoral temperature fluctuations may affect the fracture performance of successful zirconia restorations. To fill this gap, the purpose of this study is to evaluate and compare the influence of thermocycling on fracture resistance and mode of failure of monolithic zirconia crowns luted with Rely X™ U200 and BreezeTMself-adhesive resin cements as well as imply the effect of adding 2 % of polylysine (PLS) to these cements. Materials: 64 maxillary premolars were milled out of zirconia blocks using CAD/CAM milling system. They were divided into four groups (n = 16) according to the cement type. Four different resin cements were used (RelyXTMU200, Breeze™, RelyX™ U200 with 2 % PLS

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Wed Jan 01 2025
Journal Name
Modern Sport
Vertical Resistance and Its Relationship with Speed-Strength and Biomechanical Variables During the Takeoff Phase and the Performance of Selected Activities in Individual and Team Sports
...Show More Authors

Jumping ability is a fundamental variable in many sports, as its execution requires an integration of muscular strength Q1 and certain biomechanical variables. This is particularly evident in gymnastics jumping events and jump shots in ball games, both of which rely on a high level of vertical resistance. Vertical resistance serves as an indicator of an athlete’s ability to overcome their body weight while counteracting gravitational force to achieve optimal performance. As such, it is considered one of the key factors in movements that demand explosive power and speed. The researchers believe that despite the significant relationship between vertical resistance, speed-strength of the arms and legs, and certain biomechanical varia

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Tue Jun 01 2021
Journal Name
International Medical Journal V
Acceleration of Tooth Movement in Orthodontics: A Review of Literature
...Show More Authors

Objectives: The demand for orthodontic treatment is nowadays increasing significantly for aesthetic improvement and to correct various kinds of malocclusion, yet the prolonged treatment time remains the main obstacle. This review aimed to demonstrate various orthodontic techniques and highlight the evidence-based successful approaches used for acceleration of orthodontic tooth movement. Materials and Methods: Data and sources of information pertaining to accelerated orthodontic tooth movement premised on English-written articles were searched using electronic databases including Google Scholar, Scopus, PubMed and MEDLINE. Results: This review demonstrated the availability of different surgical and non-surgical methods to enhance tooth movem

... Show More
View Publication Preview PDF
Publication Date
Mon Jan 01 2024
Journal Name
Aip Conference Proceedings
Investigation in vitro the effect of X-rays, gamma rays and beta particles on the physical and structural characteristics of human teeth
...Show More Authors

View Publication
Scopus (1)
Crossref (2)
Scopus Crossref
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
Stability constants of iron(II) supported and lead(II) complexes
...Show More Authors

Overall enthalpy and entropy of complex formation were calculated from stability constant measurements at different tempreture also experimental results

View Publication Preview PDF
Publication Date
Wed Nov 15 2023
Journal Name
Bionatura
Evaluation of frictional forces between aesthetic brackets and archwires in wet conditions (An in-vitro study)
...Show More Authors

Frictional resistance occurs whenever sliding happens, negatively impacting treatment outcomes and duration. It is a clinical challenge and must be dealt with efficiently to achieve the best orthodontic results. Aims of this study: compare and evaluate the static frictional forces under the wet condition to mimic the oral environment produced by using a polycrystalline ceramic bracket, monocrystalline ceramic bracket, 0.014 of an inch nickel-titanium (Rhodium coated archwires, and ilusio aesthetic archwires), and 0.019 x 0.025 of an inch stainless steel (Rhodium coated archwires, and ilusio aesthetic archwires). Ninety-six aesthetic brackets (48 monocrystalline and 48 polycrystalline brackets) were used and stored in different incub

... Show More
View Publication Preview PDF
Crossref (1)
Scopus Crossref