It is well known that monotherapy does not provide therapeutic response in all hypertensive. Somepatients show an excellent response, while in others there is a poor response. Combinationantihypertensive therapy is administered when blood pressure is inadequately controlled bymonotherapy to achieve a balanced and additive antihypertensive effect with minimum adverse effects.Both angiotensin converting enzyme (ACE) inhibitors and dihydropyridine type of calcium antagonistsare well established and widely used in monotherapy. An understanding of differences in themechanism of action of these agents allows a logical approach for the use of these agents as acombination therapy. This study was designed to evaluate the possible beneficial effects of long actingcalcium channel blocker, amlodipine and the long acting Angiotensin converting enzyme (ACE)inhibitor, lisinopril given either alone or in combination in patients with essential hypertension on lipidprofile (LDL-C and HDL-C) and on other parameters using a randomized double blind, crossoverstudy. The study includes 150 patients with systolic blood pressure (SBP)>140 mmHg and diastolicblood pressure (DBP) >90 mmHg received amlodipine 5 mg, lisinopril 5 mg and their combinationprior randomization schedule. Systolic, diastolic blood pressure and pulse rate were recorded at weeklyintervals while, serum levels of urea, creatinine, LDL-C and HDL-C where recorded at monthlyintervals, the duration of this study was 3 months. Results were obtained using paired students t-test,differences were considered significant with (p<0.05).A significant decline in SBP and DBP in all treatment groups (p<0.05) was recorded, the reductiontend to be more pronounced in the combination group. Moreover, there was a significant effect ofcombination on the heart rate, serum level of urea and creatinine, beside that, the level of HDL wassignificantly elevated with amlodipine and combination. We concluded that combination had additionalblood pressure lowering effect when compared either with amlodipine or lisinopril alone, in addition tothe greater effect on lipid profile which demonstrated that this combination is potentialantiatherosclerotic agent.
Free vibration behavior was developed under the ratio of critical buckling temperature of laminated composite thin plates with the general elastic boundary condition. The equations of motion were found based on classical laminated plate theory (CLPT) while the solution functions consists of trigonometric function and a continuous function that is added to guarantee the sufficient smoother of the so-named remaining displacement function at the boundaries, in this research, a modified Fourier series were used, a generalized procedure solution was developed using Ritz method combined with the imaginary spring technique. The influences of many design parameters such as angles of layers, aspect ratio, thickness ratio, and ratio of initial in-
... Show MoreHeuristic approaches are traditionally applied to find the optimal size and optimal location of Flexible AC Transmission Systems (FACTS) devices in power systems. Genetic Algorithm (GA) technique has been applied to solve power engineering optimization problems giving better results than classical methods. This paper shows the application of GA for optimal sizing and allocation of a Static Compensator (STATCOM) in a power system. STATCOM devices used to increase transmission systems capacity and enhance voltage stability by regulate the voltages at its terminal by controlling the amount of reactive power injected into or absorbed from the power system. IEEE 5-bus standard system is used as an example to illustrate the te
... Show MoreIn this work the radioactive wastes in the Old Russian
Cemetery Al -Tuwaitha site were classified according to risks for
workers who are involved in the retrieval process. The exposure
assessment results expressed as estimates of radionuclide intakes by
inhalation and ingestion, exposure rates and duration for external
exposure pathways, and committed effective dose equivalents to
individuals from all relevant radionuclides and pathways. Results
showed the presence of natural radionuclides Ra-226, Th-234 and K-
40, as well as the produced radionuclide Cs-137 and Eu-152 in the
cemetery wells. The absorbed doses from the waste were classified to
two categories; exempt waste and low level waste according to
Background: preparation of root canals is an important step in root canal treatment. Mechanical instrumentation of root canals cause an irregular layer of debris, known as the smear layer. As a result, several studies reported that preferring the removal of the smear layer. Objective: To study the influence of the energy (100 mJ) of Erbium, Chromium: Yttrium Scandium Gallium Garnet (Er,Cr:YSGG) laser at short pulse duration (60 μs) on smear layer removal of apical third after using Photon induced photoacoustic streaming technique. Materials and methods: Eighteen straight single-rooted mandibular premolars were used. The roots length were uniform to 14mm from the anatomic apex and
... Show MoreThe simulation of passively Q-switching is four non – linear first order differential equations. The optimization of passively Q-switching simulation was carried out using the constrained Rosenbrock technique. The maximization option in this technique was utilized to the fourth equation as an objective function; the parameters, γa, γc and β as were dealt with as decision variables. A FORTRAN program was written to determine the optimum values of the decision variables through the simulation of the four coupled equations, for ruby laser Q–switched by Dy +2: CaF2.For different Dy +2:CaF2 molecules number, the values of decision variables was predicted using our written program. The relaxation time of Dy +2: CaF2, used with ruby was
... Show MoreA novel demountable shear connector for precast steel-concrete composite bridges is presented. The connector uses high-strength steel bolts, which are fastened to the top flange of the steel beam with the aid of a special locking nut configuration that prevents bolts from slipping within their holes. Moreover, the connector promotes accelerated construction and overcomes the typical construction tolerance issues of precast structures. Most importantly, the connector allows bridge disassembly. Therefore, it can address different bridge deterioration scenarios with minimum disturbance to traffic flow including the following: (1) precast deck panels can be rapidly uplifted and replaced; (2) connectors can be rapidly removed and replaced; and (
... Show More