It is well known that monotherapy does not provide therapeutic response in all hypertensive. Somepatients show an excellent response, while in others there is a poor response. Combinationantihypertensive therapy is administered when blood pressure is inadequately controlled bymonotherapy to achieve a balanced and additive antihypertensive effect with minimum adverse effects.Both angiotensin converting enzyme (ACE) inhibitors and dihydropyridine type of calcium antagonistsare well established and widely used in monotherapy. An understanding of differences in themechanism of action of these agents allows a logical approach for the use of these agents as acombination therapy. This study was designed to evaluate the possible beneficial effects of long actingcalcium channel blocker, amlodipine and the long acting Angiotensin converting enzyme (ACE)inhibitor, lisinopril given either alone or in combination in patients with essential hypertension on lipidprofile (LDL-C and HDL-C) and on other parameters using a randomized double blind, crossoverstudy. The study includes 150 patients with systolic blood pressure (SBP)>140 mmHg and diastolicblood pressure (DBP) >90 mmHg received amlodipine 5 mg, lisinopril 5 mg and their combinationprior randomization schedule. Systolic, diastolic blood pressure and pulse rate were recorded at weeklyintervals while, serum levels of urea, creatinine, LDL-C and HDL-C where recorded at monthlyintervals, the duration of this study was 3 months. Results were obtained using paired students t-test,differences were considered significant with (p<0.05).A significant decline in SBP and DBP in all treatment groups (p<0.05) was recorded, the reductiontend to be more pronounced in the combination group. Moreover, there was a significant effect ofcombination on the heart rate, serum level of urea and creatinine, beside that, the level of HDL wassignificantly elevated with amlodipine and combination. We concluded that combination had additionalblood pressure lowering effect when compared either with amlodipine or lisinopril alone, in addition tothe greater effect on lipid profile which demonstrated that this combination is potentialantiatherosclerotic agent.
The inhibitive action of a blend of sodium nitrite/sodium hexametaphosphate (SN+SHMP) on corrosion of carbon steel in simulated cooling water systems (CWS) has been investigated by weight loss and electrochemical polarization technique. The effect of temperature, velocity, and salts concentrations on corrosion of carbon steel were studied in the absence and presence of mixed inhibiting blend. Also the effect of inhibitors blend concentrations (SN+SHMP), temperatures, and rotational velocity, i.e., Reynolds number (Re) on corrosion rate of carbon steel were investigated using Second-order Rotatable Design (Box-Wilson Design) in performing weight loss and corrosion potential approach. Electrochemical polarization measurements
... Show MoreThe research aims to determine the mix of production optimization in the case of several conflicting objectives to be achieved at the same time, therefore, discussions dealt with the concept of programming goals and entrances to be resolved and dealt with the general formula for the programming model the goals and finally determine the mix of production optimization using a programming model targets to the default case.
The fractional free volume (Fh) in polystyrene (PS) as a function of neutron -irradiation dose has been measured, using positron annihilation lifetime (PAL) method. The results show that Fh values decreased with increasing n-irradiation dose up to a total dose of 501.03× 10-2 Gy.
A percentage reduction of 2.14 in Fh values is noticed after the initial n-dose corresponding to a percentage reduction in the free volume equal to 42.14/Gy.
The total n-dose induces a percentage reduction of 7.26, corresponding to a percentage reduction of 1.45/Gy. These results indicate that cross -linking is the predominant process induced by n-irradiation.
The results suggest that n-irradiation induces structure changes in PS, causing cross-linking
Abstract
The aim of the present work is to control of metal buried corrosion by alteration the media method. This method depended on the characteristics of each media. The corrosion rates in different media (soil, sand, porcelanite stone and gravel) for specimens of low carbon steel were measured by two methods weight loss method and polarization method, weight loss measured by buried specimens in these medias separately for 90 days. The polarization method includes preparing of specimen and salt solutions have electrical resistivity equivalent electrical resistivity of these media. The corrosion rate of two method results in (soil > sand> porcelainte stone> gravel). The lower corrosion rate happene
... Show MoreIn this article the unsteady magnetohydrodynamics oscillating flow of third order fluid with free stream velocity is proposed. It is found that the motion equation is controlled by five dimensionless parameters namely the coecostic parameter 4, viscoelostic parameter ?,acceleration/deceleration c,suction/blowing d and material constants ? . The effect of each of these parameters upon the velocity distribution is analysised
A new, easy‐to‐manufacture, and low‐cost integrated cubical solar collector tank for domestic usage is concerned in this work. Three models are prepared, side by side, and tested to point out their seasonal performance. Tank Model I has three vertical sides, black painted and glazed to act as an absorber; the other sides are insulated. Tank Model II has two black painted and glazed sides, with four insulated surfaces. The models are south‐oriented at different positions and tested versus the conventional tank (Model III) to validate and assess their performance in summer and winter. In summer, the temperatures in Models I and II are lower than those for Model III since they have insulated sid
The thermal and electrical performance of different designs of air based hybrid photovoltaic/thermal collectors is investigated experimentally and theoretically. The circulating air is used to cool PV panels and to collect the absorbed energy to improve their performance. Four different collectors have been designed, manufactured and instrumented namely; double PV panels without cooling (model I), single duct double pass collector (model II), double duct single pass (model III), and single duct single pass (model IV) . Each collector consists of: channel duct, glass cover, axial fan to circulate air and two PV panel in parallel connection. The temperature of the upper and lower surfaces of PV panels, air temper
... Show More
