A compact microstrip six-port reflectometer (SPR) with extended bandwidth is proposed in this paper. The design is based on using 16-dB multi-section coupled line directional couplers and a multi-section 3-dB Wilkinson power divider operating from 1 to 6 GHz. The proposed SPR employs only two calibration standards: a matched load and an open load. As compared to other dielectric substrates, fabricating the proposed SPR involves using a low-cost (FR4) substrate. A novel algorithm is also proposed to estimate the complex reflection coefficient over the frequency ranges at which the standard performance of the circuit components is not fully satisfied. The new algorithm is based on the circles’ intersection points, which have been derived from basic SPR equations, to estimate the complex reflection coefficient. To validate the SPR performance, a multiband microstrip patch antenna has been measured and the resulted reflection coefficient is compared with those obtained using a vector network analyzer (VNA). Results show that the proposed SPR provides a good estimation of the complex reflection coefficient within the frequency range of 1 GHz to 8 GHz. Owing to its compact size and ease of fabrication, the proposed reflectometer is suitable for various microwave broadband applications.
Biped robots have gained much attention for decades. A variety of researches have been conducted to make them able to assist or even substitute for humans in performing special tasks. In addition, studying biped robots is important in order to understand human locomotion and to develop and improve control strategies for prosthetic and orthotic limbs. This paper discusses the main challenges encountered in the design of biped robots, such as modeling, stability and their walking patterns. The subject is difficult to deal with because the biped mechanism intervenes with mechanics, control, electronics and artificial intelligence. In this paper, we collect and introduce a systematic discussion of modelin
Enamel White Spot Lesions (EWSLs) are a common dental condition characterized by being opaque or chalky white in appearance. In this review, an overview of the etiology, prevention, and treatment techniques for EWSLs is presented. Enamel demineralization caused by bacteria in dental plaque which releases acids upon the consumption of fermentable carbohydrates causing mineral loss is thought to be the main cause of those lesions, which could be predisposed through orthodontic treatment, poor diet, inadequate oral hygiene and certain medical conditions. So, sustaining an adequate carbohydrate consumption, proper fluoride exposure and good oral hygiene are some of the practices which aid in these lesions’ prevention. Although the suc
... Show MoreAASAH Enass J Waheed, Shatha MH Obaid, Research Journal of Pharmaceutical, Biological and Chemical Sciences, 2019 - Cited by 5
The study aimed to monitor the concept of reputation in the previous literature, its relationship to mental image and identity, and to reveal recent trends in its measurement Techniques.
The study relied on a descriptive approach using library survey and comparative analysis, and the study reached following conclusions:
Despite the beginning of the first signs of reputation In the fifties of the last century, however, Defining and standardizing the concept with clear and specific dimensions began in the 1990s and the beginning of the third millennium. The concept of reputation refers to the stakeholders’ overall evaluation of organizations, which reflects their perceptions of
... Show MoreThe magnetic properties of a pure Nickel metal and Nickel-Zinc-Manganese ferrites having the chemical formula Ni0.1(Zn0.4Mn0.6)0.9Fe2O4 were studied. The phase formation and crystal structure was studied by using x-ray diffraction which confirmed the formation of pure single spinel cubic phase with space group (Fd3m) in the ferrite. The samples microstructure was studied with scanning electron microstructure and EDX. The magnetic properties of the ferrite and nickel metal were characterized by using a laboratory setup with a magnetic field in the range from 0-500 G. The ferrite showed perfect soft spinel phase behavior while the nickel sample showed higher magnetic loss an
... Show More