In the present work the clathrate hydrate dissociation enthalpies of refrigerant R134a+ water system, and R134a + water + salt system were determined. The heat of dissociation of three types of aqueous salts solutions of NaCl, KBr and NaF at three concentrations (0.09, 0.17and 0.26) mol·kg−1 for each salt type, were enthalpy measured. The Clapeyron equation was used tocalculate heat of dissociation of experimental data for binary and ternary system.In order to find the effect of compressibility factor on heat dissociation enthalpy, the study was conducted by using equation of state proposed by Peng and Robinson Stryjek-Vera (PRSV). The obtained results of dissociation enthalpy for binary system were (143.8) kJ.mol-1 without gas compressibility factor (z) and (136.08) kJ.mol-1 with z where the variation between two values was (5.3%). For ternary system (R134a+ water +NaCl) at three concentrations of this salt, the calculated values were in the range of (146.7 - 154.1) kJ.mol-1without z and (138.02-145.14) kJ.mol-1with z where the variation rang between two values was (5.8-5.7) %. The other two types of salts given similar results within (0.886 - 0.129) % deviation rang about NaCl results without z and (0.818-0.149) % deviation rang with z values.
Background: Debonding and fracture of artificial teeth from denture bases are common clinical problem, bonding of artificial teeth to heat cure acrylic and high impact heat cure acrylic denture base materials with autoclave processing method is not well known. The aim of this study was to evaluate the effect of autoclave processing method on shear bond of artificial teeth to heat cure denture base material and high impact heat cure denture base material. Materials and methods: Heat polymerized (Vertex) and high impact acrylic (Vertex) acrylic resins were used. Teeth were processed to each of the denture base materials after the application of different surface treatments. The sample (which consist of artificial tooth attached to the dentur
... Show MoreObjective: To Evaluate the Roley of Cytotoxic T-Lymphocytek antigen 4 Polymorphism and soluble immune checkpoint level (PD-1,PDL-1 and CTLA-4 ) in SARS-Cov-2 patients. Methods: Fromt October 2020 to April 2021, the currentk study was conducted in Baghdad-Iraq. Ninety patients with Confirmatory SARS-Cov-2 by PCR were inclusion in the study, and they were seeking treatment at Medical City in Baghdad's Teaching Hospital (BTH). Patients with SARS-Cov-2 were divided into two groups: those with Sever SARS-Cov-2 symptom and those with mild - moderate SARS-Cov-2 symptoms (cross sectional study. Patients with another form of autoimmune illness, malignant, diabetes, under the age of 18 and pregnant women were excluded. Results: Data rega
... Show MoreTraumatic radial nerve injury in humeral shaft fracture is the most common traumatic nerve injury in long-bone fracture, with overall prevalence 2-18%, ranging from traction to complete transection. Spontaneous recovery may reach 88%. The aim of the study is to assess the sensitivity & specificity of the ultrasound to detect the radial nerve injury and to see if this can be used as a diagnostic test. This is a prospective study on 17 adult patients with a closed fracture of the humeral shaft, dividing into two groups, the first group of 7 patients had signs and symptoms of radial nerve palsy at presentation and the second group of 10 patients had intact radial nerve function was considered as a control group. All these patients had at leas
... Show MoreIn this study, iron was coupled with copper to form a bimetallic compound through a biosynthetic method, which was then used as a catalyst in the Fenton-like processes for removing direct Blue 15 dye (DB15) from aqueous solution. Characterization techniques were applied on the resultant nanoparticles such as SEM, BET, EDAX, FT-IR, XRD, and zeta potential. Specifically, the rounded and shaped as spherical nanoparticles were found for green synthesized iron/copper nanoparticles (G-Fe/Cu NPs) with the size ranging from 32-59 nm, and the surface area was 4.452 m2/g. The effect of different experimental factors was studied in both batch and continuous experiments. These factors were H2O2 concentration, G-Fe/CuNPs amount, pH, initial DB15
... Show MoreThe aim of the research is to identify the trends of Saudi society towards visiting art galleries and museums in light of economic and social transformations after the implementation of the 2030 vision plans. The importance of the research is to track the reasons behind the reluctance of members of society to visit such cultural institutions, and to plan proposals and recommendations for how to attract members of society and motivate them. This research followed the descriptive approach, and the study sample reached 103 members of the Saudi community. several research tools were used in this research such as questionnaire, personal interviews in addition to the researcher notes. The results concluded that the art galleries attract the ap
... Show MoreObjective: To compare the radiological and functional outcomes of patients of Comminuted intraarticular distal radius fractures treated with or without bone marrow injection along with external fixator ligamentotaxis. Methodology: This prospective comparative study on 41 patients with comminuted intra-articular lower end radius fractures distributed patients randomly into two groups depending on whether an aspirate of bone marrow was injected at the fracture site two weeks after fracture management with external fixation ligamentotaxis. Results: The mean age was 35.8 years, with male predominance. The radiological parameters (radial height, radial inclination, and volar tilt) at the 6th month follow up were lower in the group who did not re
... Show MoreRemovable dental prostheses remain a reliable treatment for edentulous patients. Conventional fabrication requires multiple steps, whereas computer-aided design and manufacturing (CAD-CAM), particularly 3D printing, offers faster and more cost-effective alternatives. This in vitro study aimed to evaluate the effect of sandblasting on surface roughness and shear bond strength of silicone soft liner bonded to 3D-printed and heat-cured acrylic denture base materials. Eighty specimens were divided into four groups: heat-cured control, 3D-printed control, heat-cured sandblasted, and 3D-printed sandblasted. Surface roughness was measured using a profilometer, while shear bond strength was tested with a universal testing machine. D
... Show More