Preferred Language
Articles
/
alkej-88
Efficiency Enhancement of a Dual-axis Solar PV Panel Tracker Using Water-Flow Double Glazing Technique
...Show More Authors

The fall angle of sun rays on the surface of a photovoltaic PV panel and its temperature is negatively affecting the panel electrical energy produced and efficiency. The fall angle problem was commonly solved by using a dual-axis solar tracker that continually maintains the panel orthogonally positioning to the sun rays all day long. This leads to maximum absorption for solar radiation necessary to produce maximum amount of energy and maintain high level of electrical efficiency. To solve the PV panel temperature problem, a Water-Flow Double Glazing WFDG technique has been introduced as a new cooling tool to reduce the panel temperature. In this paper, an integration design of the water glazing system with a dual-axis tracker has been accomplished and experimentally tested in order to enhance the PV panel efficiency, especially at hot climates. The proposed glazing system can simultaneously perform two functions, firstly, working as a cooling tool for reducing the stored heat in the PV panel during its work and secondly as an optical filter for sun light spectrum. Optimum design factors with their levels for the glazing system were calculated according to Taguchi method. Test experiments were carried out in Baghdad city on the 20th and 21st July 2016 on the tracker with and without using the WFDG system. The obtained results show that, the PV panel temperature with using the WFDG system was significantly dropped by 44% and its efficiency increased maximally by 36.6% at solar irradiance of 1213W/m2 as compared with conventional one.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Jun 04 2018
Journal Name
Baghdad Science Journal
The Effect of Gas Flow on Plasma Parameters Induced by Microwave
...Show More Authors

In this paper, construction microwaves induced plasma jet(MIPJ) system. This system was used to produce a non-thermal plasma jet at atmospheric pressure, at standard frequency of 2.45 GHz and microwave power of 800 W. The working gas Argon (Ar) was supplied to flow through the torch with adjustable flow rate by using flow meter, to diagnose microwave plasma optical emission spectroscopy(OES) was used to measure the important plasma parameters such as electron temperature (Te), residence time (Rt), plasma frequency (?pe), collisional skin depth (?), plasma conductivity (?dc), Debye length(?D). Also, the density of the plasma electron is calculated with the use of Stark broadened profiles

View Publication Preview PDF
Scopus (19)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Sat Sep 30 2017
Journal Name
Al-khwarizmi Engineering Journal
Numerical Investigations on Heat Flow of Nanofluids in Ribs Tube Configurations
...Show More Authors

Abstract

In this paper presents two dimensional turbulent flow of different nanofluids and ribs configuration in a circular tube have been numerically investigation using FLUENT 6.3.26. Two samples of CuO and, ZnO nanoparticles with 2% v/v concentration and 40 nm as nanoparticle diameter combined with trapezoidalribs with aspect ratio of p/d=5.72 in a constant tube surface heat flux were conducted for simulation. The results showed that heat flow as Nusselt number for all cases raises with Reynolds number and volume fraction of nanofluid, likewise the results also reveal that ZnO with volume fractions of 2% in trapezoidal ribs offered highest Nusselt number at Reynolds number of Re= 30000.

Key

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Jun 01 2007
Journal Name
Al-khwarizmi Engineering Journal
Investigation of heat transfer phenomena and flow behavior around electronic chip
...Show More Authors

Computational study of three-dimensional laminar and turbulent flows around electronic chip (heat source) located on a printed circuit board are presented. Computational field involves the solution of elliptic partial differential equations for conservation of mass, momentum, energy, turbulent energy, and its dissipation rate in finite volume form. The k-ε turbulent model was used with the wall function concept near the walls to treat of turbulence effects. The SIMPLE algorithm was selected in this work. The chip is cooled by an external flow of air. The goals of this investigation are to investigate the heat transfer phenomena of electronic chip located in enclosure and how we arrive to optimum level for cooling of this chip. These par

... Show More
View Publication Preview PDF
Publication Date
Sun Jan 01 2023
Journal Name
Journal Of The Mechanical Behavior Of Materials
Groundwater flow modeling and hydraulic assessment of Al-Ruhbah region, Iraq
...Show More Authors
Abstract<p>Al-Ruhbah region is located in the southwest of Najaf Governorate. A numerical model was created to simulate groundwater flow and analyze the water quality of the groundwater, by developing a conceptual model within the groundwater modeling system software. Nineteen wells were used, 15 for pumping and four for observation. A three-dimensional model was built based on the cross-sections indicating the geologic layers of the study area, which were composed of five layers. When a distance of 1,000 m between the wells was adopted, 135 wells can be operated simultaneously. These wells were hypothetically operated at 6, 12, and 18 h intervals, with a discharge of 200, 430, and 650 m<j></j></p> ... Show More
Scopus (5)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Fri Jun 03 2022
Journal Name
International Journal Of Health Sciences
Corrosion risk assessment of the oil flow line in Southern Iraq
...Show More Authors

The risk assessment for three pipelines belonging to the Basra Oil Company (X1, X2, X3), to develop an appropriate risk mitigation plan for each pipeline to address all high risks. Corrosion risks were assessed using a 5 * 5 matrix. Now, the risk assessment for X1 showed that the POF for internal corrosion is 5, which means that its risk is high due to salinity and the presence of CO, H2S and POF for external corrosion is 1 less than the corrosion, while for Flowline X2 the probability of internal corrosion is 4 and external is 4 because there is no Cathodic protection applied due to CO2, H2S and Flowline X3 have 8 leaks due to internal corrosion so the hazard rating was very high 5 and could be due to salinity, CO2, fluid flow rate

... Show More
Preview PDF
Crossref
Publication Date
Sun Mar 04 2012
Journal Name
Baghdad Science Journal
Double Stage Cumulative Shrunken Bayes Estimator for the variance of Normal distribution for equal volume of two sample
...Show More Authors

In this article we study the variance estimator for the normal distribution when the mean is un known depend of the cumulative function between unbiased estimator and Bays estimator for the variance of normal distribution which is used include Double Stage Shrunken estimator to obtain higher efficiency for the variance estimator of normal distribution when the mean is unknown by using small volume equal volume of two sample .

View Publication Preview PDF
Crossref
Publication Date
Tue May 07 2019
Journal Name
Pain Research And Treatment
Efficacy of the LED Red Light Therapy in the Treatment of Temporomandibular Disorders: Double Blind Randomized Controlled Trial
...Show More Authors

Background. Temporomandibular dysfunction syndrome (TMD) is a common disease among dental patients. It occurs as a consequence of malfunction of the tempromandibular and/or surrounding facial muscles. LED red light therapy is not been well established, and it is important to find out the role of this technique in the treatment of temporomandibular disorders. Aim of the Study. To evaluate the efficacy of the LED red light in the treatment of the tempromandibular dysfunction syndrome. Material and Methods. Fifty students of the College of Dentistry/University of Baghdad with myofacial pain associated with Tempromandibular Disorder volunteered to participa

... Show More
View Publication Preview PDF
Scopus (8)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Tue May 07 2019
Journal Name
Pain Research And Treatment
Efficacy of the LED Red Light Therapy in the Treatment of Temporomandibular Disorders: Double Blind Randomized Controlled Trial
...Show More Authors

Background. Temporomandibular dysfunction syndrome (TMD) is a common disease among dental patients. It occurs as a consequence of malfunction of the tempromandibular and/or surrounding facial muscles. LED red light therapy is not been well established, and it is important to find out the role of this technique in the treatment of temporomandibular disorders. Aim of the Study. To evaluate the efficacy of the LED red light in the treatment of the tempromandibular dysfunction syndrome. Material and Methods. Fifty students of the College of Dentistry/University of Baghdad with myofacial pain associated with Tempromandibular Disorder volunteered to participa

... Show More
View Publication
Scopus (8)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Wed Dec 13 2017
Journal Name
Al-khwarizmi Engineering Journal
Numerical Simulation of the Collector Angle Effect on the Performance of the Solar Chimney Power Plant
...Show More Authors

Sloped solar chimney system is a solar chimney power plant with a sloped collector. Practically, the sloped collector can function as a chimney, then the chimney height can be reduced and the construction cost would be reduced.The continuity, Naver-stockes, energy and radiation transfer equations have been solved and carried out by Fluent software. The governing equations are solved for incompressible, 3-D, steady, turbulent standard model with Boussiuesq approximation  to develop for the sloped solar chimney system in this study and evaluate the performance of solar chimney power plant  in Baghdad city of Iraq numerically by Fluent (14) software with orking conditions such as solar radiation intensity (30

... Show More
View Publication Preview PDF
Publication Date
Thu Oct 01 2009
Journal Name
Iraqi Journal Of Physics
Effect of Glass Inclination of Windows Facing East and West on Solar Radiation Transmittance into Buildings
...Show More Authors

To reduce solar radiation transmittance into buildings through windows facing east or west during summer, a window inclination from vertical position is suggested. The inclination of the window glazing and the rate of unwanted solar radiation during summer can be calculated knowing the dialy inclination of the sun rays. The inclination of window glazing depends on the latitude of the position required. For instance in Baghdad which is at about 33o north latitude a slope of 15o for window glazing is sufficient to prevent about 419 MJ/m2 of total solar radiation energy from penetration during summer for clear glazing of window facing east. This value drops to about 96 MJ/m2 during winter. Therefore the ratio between the energy saved for co

... Show More
View Publication Preview PDF