This paper represents an experimental study on the application of smart control represented by the use of the fuzzy logic controller. Two-link flexible manipulators that are used in airspace and military applications are made of flexible materials characterized by low frequency and damping ratio. To solve this problem, this paper proposes the use of smart materials (piezoelectric transducers), where each link is bonded with a pair of piezoelectric transducers that act as a sensor and another as an actuator. As the arm vibrates because of the movement generated by the motor, this voltage is controlled by a regulator inside the LABVIEW® 2020 software and sends the output control voltage to the piezoelectric actuator. Experimental results show that fuzzy logic control was efficient during high amplitude and led to pronounced results in suppressing vibrations within a short time. Fuzzy logic gives more flexibility to the designer and allows him to control the system through its simple implementation. This differs from classical control, which requires a mathematical model.
Background: The aim of this in vitro study was to evaluate and compare the microleakage between Vertise Flow T M composite material and other conventional (Filtek Z250, riva light cure and SDR) composite materials when restoring CII mesial box only cavity at gingival margin through die penetration test Materials and methods: Forty maxillary first premolars were prepared with class II box design only cavities. Samples were divided into four groups of ten teeth according to material used: group I (FiltekZ250 only). Group II (SDR+FiltekZ250). Group III (Vertise Flow +FiltekZ250). Group IV (Riva light cure+ FiltekZ250). After 24 hrs. immersion in 2% in methylene blue, samples were sectioned and micro leakage was estimated. Results: None of the
... Show MoreResveratrol, (RES), a phytoalexin, is well-known for its anti-inflammatory and anti-oxidant properties. SEB, a superantigen, is known to trigger ALI and cause mortality. In the current study, we tested the effect of RES in a dual-dose model of SEB exposure that triggers ALI and causes 100% mortality in C3H/HeJ-mice. The data revealed RES attenuated SEB-induced ALI and prevented mortality. Forty eight hours post-SEB exposure, lung-infiltrating mononuclear cells were tested for microRNA expression profile to determine the epigenetic regulation by resveratrol. SEB-activated splenocytes were pre-treated with 50 μM of RES or vehicle for metabolic profile analysis by measuring oxygen consu
The primary objective of root canal therapy is adequate biomechanical preparation of root canal system followed by 3D obturation.in clinics we are encountered with several anatomical variations, which we need to manage efficiently. One of the major factors responsible for failure of root canal therapy is missed canals. Recent technological advances have given the clinician opportunity to identify anatomical variations and treat them to satisfaction.
1-Objective:- Polyphenols are biochemical compounds with antioxidant activity against differences diseases related to Lipid peroxidation such as diabetes mellitus. Polyphenols distributed widely in medical plants, the aim of the study is to extract and analyze some polyphenolic compounds from grape seeds and examine their effects on (STZ) induced diabetic mice. 2-Methods:- In the present study , a group of polyphenols has been extracted from Iraq
... Show MoreBackground: Rehabilitation of the carious tooth to establish tooth structure integrity required cavity design that show a benign stress distribution. The aim of this study was to investigate the influence of the cavity position on the stress values in the reamining tooth structure restored with amalgam or resin composite. Materials and methods: Seven 2-D models of maxillary first premolar include class I cavity design was prepared, one sound tooth (A) 3 composite (B1, B2, and B3) and 3 amalgam (C1, C2, and C3). In design (BI and C1) the cavity position is in the mid distance between bacc-lingual cusp tip, design (B2 and C2) and (B3 and C3) shifted toward the buccal cusp and the lingual cusp for 0.5 mm respectively. One hundred N vertical
... Show MoreAннотация
В статье представлены явления полисемии и омонимии в специализированной терминосистеме, а именно в геодезической терминологии; определены предпосылки и причины возникновения полисемии и омонимии в профессиональном языке в области геодезии и кадастра; установлены различия и взаимосвязь между понятиями омонимия и полисемия; выделены главных типы полисемантических тер
... Show More