Preferred Language
Articles
/
alkej-631
Free Convective Heat Transfer with Different Sections Lengths Placed at the Exit of a Vertical Circular Tube subjected to a Constant Heat Flux
...Show More Authors

A free convective heat transfer from the inside surface of a uniformly heated vertical circular tube has been experimentally investigated under a constant wall heat flux boundary condition for laminar air flow in the ranges of RaL from 6.9108 to 5109. The effect of the different sections (restrictions) lengths placed at the exit of the heated tube on the surface temperature distribution, the local and average heat transfer coefficients were examined. The experimental apparatus consists of aluminum circular tube with 900 mm length and 30 mm inside diameter (L/D=30). The exit sections (restrictions) were included circular tubes having the same inside diameter as the heated tube but with different lengths of 600 mm (L/D=20), 900 mm (L/D=30), 1200 mm (L/D=40), 1500 mm (L/D=50), and 1800 mm (L/D=60). It was found that the surface temperature along the tube axial distance would be higher for restriction with length of 1800 mm (L/D=60) and it would be smaller for the restriction with length of 1200 mm (L/D=40). The results show that the local Nux and average Nusselt number were higher values for the restriction with length of 1200 mm (L/D=40) and smaller values for the restriction with length of 1800 mm (L/D=60). The results were correlated with empirical equations and presented as Logagainst Log for each case investigated and a general empirical equation was proposed for all cases.

 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Jan 13 2020
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
Analyzing the net profitability of total investments using a constructed mathematical model: An applied research at Iraqi Middle East Bank for investment for the financial years 2008-2010
...Show More Authors

The trading banks in Iraq invest their funds according to regulations imposed by the Central Bank in Iraq in different financial fields like stock exchanges, acquire stocks as assets that could be sold at any time as well as make loans and contributing in corporations establishment also magnitude foreign capital through direct contacts with foreign exchange markets.

We can summarize the problem of this paper as shortage in mathematical models that used in studying and analyzing these investments and according to this problem we used (a constructed mathematical model ) consists of three major indicators: profitability of total investment assets which is divided into three sub-indicators: owners equity risk indicator, debits risk i

... Show More
View Publication Preview PDF
Publication Date
Fri Sep 30 2022
Journal Name
Energy Science And Engineering
CFD analysis on optimizing the annular fin parameters toward an improved storage response in a triple‐tube containment system
...Show More Authors

Scopus (42)
Crossref (39)
Scopus Clarivate Crossref
Publication Date
Tue Aug 15 2017
Journal Name
Research Journal Of Applied Sciences, Engineering And Technology
A Prototype and Roadmap for Transition to IPv6 with Performance Evaluation
...Show More Authors

The migration from IPv4 to IPv6 can not be achieved in a brief period, thus both protocols co-exist at certain years. IETF Next Generation Transition Working Group (NGtrans) developed IPv4/IPv6 transition mechanisms. Since Iraq infrastructure, including universities, companies and institutions still use IPv4 protocol only. This research article tries to highlight, discuss a required transition roadmap and extend the local knowledge and practice on IPv6. Also, it introduces a prototype model using Packet tracer (network simulator) deployed for the design and implementation of IPv6 migration. Finally, it compares and evaluates the performance of IPv6, IPv4 and dual stack using OPNET based on QoS metrics such as throughput, delay and point to

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Plant Archives
The effect of adding some essential oils to the physicochemical properties of frozen beef sausage with different storage periods
...Show More Authors

Scopus (3)
Scopus
Publication Date
Sun Mar 01 2015
Journal Name
Baghdad Science Journal
Variation of Faba Beans (Vicia faba L.) Traits Induced By Heat, Electric Shock and Mutagen Nitrous Acid
...Show More Authors

This research was carried out to determine the impact of heat shock, electric shock and seeds in soaking nitrous acid mutagen solution on three cultivars of faba beans plant (Zaina, Aguadulce and Local) at the year 2012-2013. Factorial experiment was arranged in randomized complete block design (RCBD) with three replicates were used. The results showed that heat shock lead to early plants of 50% in flowering and an increase in the number of branches/plant and the number of seeds/pod compared to other treatments, whereas the seeds soaked in nitrous acid mutagen solution gave the highest plant height, leaf area index, number of pods/plant, seed weight, seed yield kg/ha, and did not differ significantly with treatment of electric shock in the

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Jul 28 2018
Journal Name
Journal Of Engineering
Experimental and Numerical Study Effect of Using Nanofluids in Perforated Plate Fin Heat Sink for Electronics Cooling
...Show More Authors

An experimental and numerical investigation of the effect of using two types of nanofluids with suspending of (Al2O3 and CuO) nanoparticles in deionized water with a volume fraction of (0.1% vol.), in addition to use three types of fin plate configurations of (smooth, perforated, and dimple plate) to study the heat transfer enhancement characteristics of commercial fin plate heat sink for cooling computer processing unit. All experimental tests under simulated conditions by using heat flux heater element with input power range of (5, 16, 35, 70, and 100 W). The experimental parameters calculated are such as water and nanofluid as coolant with Reynolds number of (7000, 8000, 9400 and 11300); the air

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Tue Sep 08 2020
Journal Name
Baghdad Science Journal
A comparison among Different Methods for Estimating Regression Parameters with Autocorrelation Problem under Exponentially Distributed Error
...Show More Authors

Multiple linear regressions are concerned with studying and analyzing the relationship between the dependent variable and a set of explanatory variables. From this relationship the values of variables are predicted. In this paper the multiple linear regression model and three covariates were studied in the presence of the problem of auto-correlation of errors when the random error distributed the distribution of exponential. Three methods were compared (general least squares, M robust, and Laplace robust method). We have employed the simulation studies and calculated the statistical standard mean squares error with sample sizes (15, 30, 60, 100). Further we applied the best method on the real experiment data representing the varieties of

... Show More
View Publication Preview PDF
Scopus Clarivate Crossref
Publication Date
Tue Aug 03 2021
Journal Name
Key Engineering Materials
Numerical Investigation of New Cooling Method for Clinker Flow in Opposite Direction with Airflow at Different Height Ratios
...Show More Authors

Several parameters affect the properties of Portland cement and one of these parameters is the cooling rate of the clinker. If the effectiveness of the cooling method of the clinker increases, a good enhancement in the properties of Portland cement will be found. Depending on the new cooling method suggestion by Nasr et. al. [20], the counter pattern of air clinker flow was studied using (FLUENT 6.3.26). The dimensions of the cooling room in grate cooler, the constant mass flow rate of both clinker and air, different height ratios, and different clinker porosity were considered in this numerical work. The results show that the heat transfers in the first half of the cooling room (0 < X < 0.9 m) is larger than that in the secon

... Show More
View Publication
Scopus (1)
Crossref (2)
Scopus Crossref
Publication Date
Mon Jun 30 2014
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Experimental Determination of the Elastic and Viscous Behavior of Polycarbonate Melts at Different Temperatures and Their Relationship to the Steady State Viscosity via the Cox-Merz Rule
...Show More Authors

Rheological instrument is one of the basic analytical measurements for diagnosing the properties of polymers fluids to be used in any industry. In this research polycarbonate was chosen because of its importance in many areas and possesses several distinct properties.
Two kinds of rheometers devices were used at different range of temperatures from 220 ˚C-300 ˚C to characterize the rheological technique of melted polycarbonate (Makrolon 2805) by a combination of different investigating techniques. We compared the results of the linear (oscillatory) method with the non-linear (steady-state) method; the former method provided the storage and the loss modulus of melted polycarbonate, and presented the Cox-Merz model as well. One of the

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 17 2019
Journal Name
Baghdad Science Journal
Plasma Spectroscopy Diagnostics of V2O5 at a Variable of Operating Power and Pressure With Radio Frequency Magnetron Sputtering.
...Show More Authors

   In this paper, we investigate the basic characteristics of "magnetron sputtering plasma" using the target V2O5. The "magnetron sputtering plasma" is produced using "radio frequency (RF)" power supply and Argon gas. The intensity of the light emission from atoms and radicals in the plasma measured by using "optical emission spectrophotometer", and the appeared peaks in all patterns match the standard lines from NIST database and employed are to estimate the plasma parameters, of computes electron temperature and the electrons density. The characteristics of V2O5 sputtering plasma at multiple discharge provisos are studied at the "radio frequency" (RF) power ranging from 75 - 150 Wat

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Clarivate Crossref