In the present work, steady two – dimensional laminar natural convection heat transfer of Newtonian and non-Newtonian fluids inside isosceles triangular enclosure has been analyzed numerically for a wide range of the modified Rayleigh numbers of (103 ≤ Ra ≤ 105), with non-dimensional parameter (NE) of Prandtl – Eyring model ranging from (0 to 10), and modified Prandtl number take in the range (Pr* =1,10, and 100). Two types of boundary conditions have been considered. The first, when the inclined walls are heated with different uniform temperatures and the lower wall is insulated. The second, when the bottom wall is heated by applying a uniform heat flux while the inclined walls at the constant cold temperature. Also, the non-Newtonian fluids under consideration were assumed to obey the Prandtl – Eyring model..The results are presented in terms of isotherms and streamlines to show the behavior of the fluid flow and temperature fields. In addition, some graphics are presented the relation between average Nusselt number and the various parameters. The results show the effect of non – dimensional parameter (NE) on the velocity and temperature profiles. They also show that the average Nusselt number is a strong function of modified Rayleigh number, modified Prandtl number, non-dimensional parameter, and the boundary conditions. Four different correlations have been made to show the dependence of the average Nusselt number on the non-dimensional parameter, the modified Rayleigh and Prandtl numbers.
A numerical investigation was performed on triangular solar air collectors by integrating unique layouts of triangular and alternating triangular copper metal foams with graded and non-graded pore densities. A three-dimensional CFD model was established to solve the governing equations of coupled systems for porous and non-porous domains. The two-energy-equations model was implemented to simulate heat transfer in porous media. The mathematical model was validated with numerical and experimental tests, with maximum mean absolute percentage error of 5% and 7%, respectively. To compromise heat transfer improvement with pressure losses, a partial metal foam insertion was adopted, covering 10% to 25% of the air duct volume. The findings indicate
... Show MoreAbstract
This work deals with a numerical investigation to evaluate the utilization of a water pipe buried inside a roof to reduce the heat gain and minimize the transmission of heat energy inside the conditioning space in summer season. The numerical results of this paper showed that the reduction in heat gain and energy saving could be occurred with specific values of parameters, like the number of pipes per square meter, the ratio of pipe diameter to the roof thickness, and the pipe inlet water temperature. Comparing with a normal roof (without pipes), the results indicated a significant reduction in energy heat gain which is about 37.8% when the number of pipes per m
... Show MoreSome have considered the dialectic in form and meaning from different points of view, and dismantled them from each other, and this view is correct if we adopt according to the logic of Aristotle when it comes to dialectic, the dialectic of form and meaning has different aspects and does not share a single line in terms of conceptual meaning, the form is the appearance What the recipient sees with the help of cognitive tools, the content or content is the mental meaning, which in turn depends on his own tools, and to this extent this view is correct, and the intellectual content or meaning of the artwork or the human message that the artist wants to convey to the viewer.
The research included four chapters. The first chapter included
In recent years, data centre (DC) networks have improved their rapid exchanging abilities. Software-defined networking (SDN) is presented to alternate the impression of conventional networks by segregating the control plane from the SDN data plane. The SDN presented overcomes the limitations of traditional DC networks caused by the rapidly incrementing amounts of apps, websites, data storage needs, etc. Software-defined networking data centres (SDN-DC), based on the open-flow (OF) protocol, are used to achieve superior behaviour for executing traffic load-balancing (LB) jobs. The LB function divides the traffic-flow demands between the end devices to avoid links congestion. In short, SDN is proposed to manage more operative configur
... Show MoreCopper (Cu) Zinc (Zn) and Magnesium (Mg) in serum, RBC, urine and dialyzate fluids were
studied in 39 patients, who have been undergoing chronic haemodialysis treatment. They were
divided in to polyuric , oliguric and anuric depending on their urinary output. Elevated serum and
RBC Mg was observed before dialysis, while decreased serum and RBC level was noticed except
serum Mg of polyuric patients. Before dialysis elevated serum and RBC Zn were observed. While
after dialysis these parameters were increased. Normal RBC Cu value before dialysis was observed.
While low serum Cu was noticed. After dialysis serum Cu showed raised value, while RBC level
decreased in oliguric and increased in polyuric patients. Zn / Cu rati
This work was conducted to study limestone rock wettability alteration to enhance oil recovery by flooding using different Nano silica (NS) sizes suspended in saline water and compared with flooding solution of polyethylene glycol (PEG) polymer and sodium dodecyl sulfate (SDS) surfactant, the stability of nanofluids measured by zeta potential. In the flooding system, the secondary recovery by silica nanofluids (0.01 wt. % NS concentration) achieved an oil recovery of 35vol. % and 26.08 vol. % for 10, 52 nm after primary recovery respectively, while PEG polymer and SDS surfactant achieved oil recovery of 5 vol. % and 10 vol. % only respectively. The stability of pressure difference approved that silica nanoparticle never causes any p
... Show MoreThe inhibitive action of Reactive Red (RR31) dye against corrosion of carbon steel in 1M acetic acid solution has been studied using gravimetric method at temperature ranged (288-318)K. The antibacterial activity for the different concentrations of RR31 dye against different bacterial species was studied. The experimental data indicates that this dye acts as a potential inhibitor for carbon-steel in acetic acid medium and the protection efficiency increase with increasing (RR31) dye. The adsorption of (RR31) dye on the carbon steel surface was found to follow Langmuir adsorption isotherm. Thermodynamic data for the adsorption process such as Gibbs free energy change ∆Gads, enthalpy change ∆Hads, and entropy change ∆Sads were estima
... Show More
