Extraction of Phenol From Industrial Water Using Different Solvents
...Show More Authors

The analysis and efficiency of phenol extraction from the industrial water using different solvents, were investigated. To our knowledge, the experimental information available in the literature for liquid-liquid equilibria of ternary mixtures containing the pair phenol-water is limited. Therefore the purpose of the present investigation is to generate the data for the water-phenol with different solvents to aid the correlation of liquid-liquid equilibria, including phase diagrams, distribution coefficients of phenol, tie-lines data and selectivity of the solvents for the aqueous phenol system.

                The ternary equilibrium diagrams and tie-lines data for systems containing Water-Phenol-Benzene, Water-Phenol-Chloroform, Water-Phenol-iso-Butyl Acetate, Water-Phenol-Butanol, Water-Phenol-Ethyl Methyl Keton and Water-Phenol-Toluene, were determined at 303 K and atmospheric pressure.

                The capacity and selectivity of these organic solvents in each of these systems were determined from the tie-lines data. The capacity of the isobutyle acetate was found to be the highest among the other solvents, and its selectivity was also the highest. Similar results also were obtained for the ethyl methyl keton but gave less capacity and selectivity as compared to the isobutyle acetate. It can be concluded that both isobutyle acetate and ethyl methyl keton are good solvents for extraction of phenol from industrial water.

                The liquid-liquid equilibrium data of ternary systems were correlated to the NRTL, UNIQUAC and UNIFAC models of activity coefficient to determine their adjustable parameters. The standard deviations from experimental compositions were calculated. Results show that the correlation may be greatly improved by applying the NRTL model with the regression criteria based on minimizing the experimental and calculating distribution coefficients SK to give an average value of the root mean square deviation about 1.436 % and in terms of the average errors in the distribution ratio for all tie-lines about 10.776 %.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Dec 30 2015
Journal Name
Al-kindy College Medical Journal
Estimation Of Left Ventricular Ejection Fraction Using Mitral Annular Displacement Derived By Speckle Tracking Echocardiography In Patients With Different Heart Diseases
...Show More Authors

Background: Speckle tracking echocardiography (STE)-derived mitral annular displacement (MAD) utilizes the speckle tracking technique to measure strain vectors, which provides accurate estimates of left ventricular ejection fraction (LVEF).Objectives: To validate the accuracy of mitral annular displacement (MAD), assessed by Speckle Tracking Echocardiography (STE), as a surrogate for determination of left ventricular systolic function in comparison to 2-Dimensions Simpson method in patients with different heart diseases.Methods : This cross-sectional study included patients who referred to outpatient department of Ibn Albitar Center for Cardiac Surgery, Baghdad, Iraq, between October 2012 and April 2013. STE continuously tracked annular

... Show More
View Publication Preview PDF
Publication Date
Sun Oct 01 2006
Journal Name
Modern Sport
The effect of using a treadmill with different incline angles in developing some functional variables among Diyala University basketball team players
...Show More Authors

تعد لعبة كرة السلة من الألعاب الرياضية التي تحتاج متطلبات بدنية ووظيفية خاصة بها، وذلك من خلال الانتقال داخل الملعب بالكرة أو بدونها والسبل للتخلص من ملاحقة الخصم أثناء الدفاع وكيفية المناورة أثناء الهجوم مع إجادة التصويب بكافة أنواعه داخل الملعب، ومن هنا تكونت مشكلة البحث في كيفية تطوير تلك العوامل الوظيفية والتي لها الأثر في الارتقاء بمستوى أداء اللاعب أثناء اللعب، وعن طريق استخدام الباحثان لطريقة جهاز ا

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 18 2019
Journal Name
Baghdad Science Journal
The Calculation and Analysis of the Total Electron Content Over Different Latitudes and Seasons Using the Numerical Trapezoidal and Simpson Methods
...Show More Authors

It has been shown in ionospheric research that calculation of the total electron content (TEC) is an important factor in global navigation system. In this study, TEC calculation was performed over Baghdad city, Iraq, using a combination of two numerical methods called composite Simpson and composite Trapezoidal methods. TEC was calculated using the line integral of the electron density derived from the International reference ionosphere IRI2012 and NeQuick2 models from 70 to 2000 km above the earth surface. The hour of the day and the day number of the year, R12, were chosen as inputs for the calculation techniques to take into account latitudinal, diurnal and seasonal variation of TEC. The results of latitudinal variation of TE

... Show More
View Publication Preview PDF
Scopus Clarivate Crossref
Publication Date
Sat Jul 01 2017
Journal Name
Global Journal Of Bio-science And Biotechnology
Efficiency of different denture disinfection methods
...Show More Authors

Dentures that are not cleaning and maintained properly may prone to contamination by different microbial pathogens that result in several oral conditions. This study was design to compare the antimicrobial effect of different denture cleansers oxalic, tartaric, citric acids and alkaline peroxide with microwave irradiation on the growth of Candida albicans and Staphylococcus aureus respectively. Microwave oven used to disinfect specimens of heat-activated acrylic resin and soft linear. Oxalic, citric, tartaric acids, and alkaline peroxide were also used. Microorganisms that tested were Candida albicans and Staphylococcus aureus separately. Treatment with microwave or tartaric acid could achieve sterilization of both hot cured acrylic resins

... Show More
Preview PDF
Publication Date
Tue Sep 08 2020
Journal Name
Baghdad Science Journal
Using Real-Time PCR to Investigate Some of Antibiotic Resistance Genes from Streptococcus agalactiae Isolates from ewe Mastitis cases in Nineveh province
...Show More Authors

In this study, from a total of 856 mastitis cases in lactating ewes, only 34 Streptococcus agalactiae isolates showed various types of resistance to three types of antibiotics (Penicillin, Erythromycin and Tetracycline). St. agalactiae isolates were identified according to the standard methods, including a new suggested technique called specific Chromogenic agar. It was found that antibiotic bacterial resistance was clearly identified by using MIC-microplate assay (dilution method). Also, by real-time PCR technique, it was determined that there were three antibiotics genes resistance ( pbp2b, tetO and mefA ). The high percentage of isolate carried of a single gene which was the Tetracycline (20.59%) followed by percentage Penicillin was

... Show More
View Publication Preview PDF
Scopus (4)
Scopus Clarivate Crossref
Publication Date
Tue Oct 07 2003
Journal Name
University Of Baghdad
A STUDY ON SOLVENT EXTRACTION OF HOLMIUM (III) WITH SUDAN BLACK B REAGENT (M.Sc. Thesis)
...Show More Authors

Preview PDF
Publication Date
Wed Jul 22 2020
Journal Name
International Journal Of Research In Pharmaceutical Sciences
Cloud point extraction method for the sensitive determination of metoclopramide hydrochloride in pharmaceutical dosage forms
...Show More Authors

In this work, a simple and very sensitive cloud point extraction (CPE) process was developed for the determination of trace amount of metoclopramide hydrochloride (MTH) in pharmaceutical dosage forms. The method is based on the extraction of the azo-dye results from the coupling reaction of diazotized MTH with p-coumaric acid (p-CA) using nonionic surfactant (Triton X114). The extracted azo-dye in the surfactant rich phase was dissolved in ethanol and detected spectrophotometrically at λmax 480 nm. The reaction was studied using both batch and CPE methods (with and without extraction) and a simple comparison between the two methods was performed. The conditions that may be affected by the extraction process and the sensitivity of m

... Show More
View Publication
Scopus (2)
Scopus Crossref
Publication Date
Thu Oct 01 2020
Journal Name
Biochemical & Cellular Archives
THE STUDY ON ABILITY OF ESCHERICHIA COLI ISOLATED FROM DIFFERENT CLINICAL CASES TO BIOFILM FORMATION AND DETECTION OF CSGD GENE RESPONSIBLE FOR PRODUCE CURLI (FIMBRIAE)
...Show More Authors

A total of 165 clinical sample included Urine, Swab wounds and Burns were collected from Baghdad Governorate. Results showed that rate all isolates of E. coli was 50(30.3%) and rate of urine infection was 46(92%) and rate of swab wounds infection 4(8%). Where was diagnostic based on streaked on MacConkey agar, then single colony was transferred to Eosin Methylene Blue (EMB). Identification some of the biochemical test included: Catalase test, Oxidase test, Indole test, Methyl red, Vogues - Proskauer test and Citrate Utilization test. Then confirmed by the Vitek - 2 Compact System. The ability of E.coli isolate to biofilm formation to be studied it is considered one of the most important factors of virulence and has role in causing injury an

... Show More
Scopus (4)
Scopus
Publication Date
Fri Sep 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Color Stability of Different Aesthetic Archwires after Immersion into Different Types of Mouthwashes(An In Vitro Study)
...Show More Authors

Background: Because of the demands for aesthetic orthodontic appliances have increased, aesthetic archwires have been widely used to meet patient's aesthetic needs. The color stability of aesthetic archwires is clinically important, any staining or discoloration will affect patient’s acceptance and satisfaction. This study was designed to evaluate the color stability of different types of aesthetic archwires after immersion into different types of mouth washes. Materials and methods: Four brands of nickel titanium coated aesthetic arch wires: Epoxy coated (Orthotechnology and G&H) and Teflon coated (Dany and Hubit) were evaluated after 1 week, 3 weeks and 6 weeks of immersion into two types of mouthwashes (Listerine with alcohol and

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Tue Apr 01 2014
Journal Name
International Journal Of Scientific & Engineering Research
Transition properties of γ-ray Emitted from levels in 90Mo using 𝝈 𝑱 method
...Show More Authors

The δ-mixing ratios have been calculated for several γ-transitions in 90Mo using the 𝛔 𝐉 method. The results are compared with other references the agreement is found to be very good .this confirms the validity of the 𝛔 𝐉 method as a tool for analyzing the angular distribution of γ-ray. Key word: population parameter, γ-ray transition, 𝛔 𝐉 method, multiple mixing ratios.

View Publication