Preferred Language
Articles
/
alkej-605
Extraction of Phenol From Industrial Water Using Different Solvents
...Show More Authors

The analysis and efficiency of phenol extraction from the industrial water using different solvents, were investigated. To our knowledge, the experimental information available in the literature for liquid-liquid equilibria of ternary mixtures containing the pair phenol-water is limited. Therefore the purpose of the present investigation is to generate the data for the water-phenol with different solvents to aid the correlation of liquid-liquid equilibria, including phase diagrams, distribution coefficients of phenol, tie-lines data and selectivity of the solvents for the aqueous phenol system.

                The ternary equilibrium diagrams and tie-lines data for systems containing Water-Phenol-Benzene, Water-Phenol-Chloroform, Water-Phenol-iso-Butyl Acetate, Water-Phenol-Butanol, Water-Phenol-Ethyl Methyl Keton and Water-Phenol-Toluene, were determined at 303 K and atmospheric pressure.

                The capacity and selectivity of these organic solvents in each of these systems were determined from the tie-lines data. The capacity of the isobutyle acetate was found to be the highest among the other solvents, and its selectivity was also the highest. Similar results also were obtained for the ethyl methyl keton but gave less capacity and selectivity as compared to the isobutyle acetate. It can be concluded that both isobutyle acetate and ethyl methyl keton are good solvents for extraction of phenol from industrial water.

                The liquid-liquid equilibrium data of ternary systems were correlated to the NRTL, UNIQUAC and UNIFAC models of activity coefficient to determine their adjustable parameters. The standard deviations from experimental compositions were calculated. Results show that the correlation may be greatly improved by applying the NRTL model with the regression criteria based on minimizing the experimental and calculating distribution coefficients SK to give an average value of the root mean square deviation about 1.436 % and in terms of the average errors in the distribution ratio for all tie-lines about 10.776 %.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Jul 08 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
The Effect of Coumarin Derivatives(compounds) on the Vibrio cholerae Isolates from Different Clinical Iraqi Sources
...Show More Authors

From a large number of bacterial samples collected from different hospital in Iraq in central  health laboratory ,only ten isolates were identified primary as Vibrio. A number of  morphology and biochemical test were carried out to complete this identification that showed all bacterial isolates were related to Vibrio cholerae .In this study  all Vibrio isolates were investigated for Bio typing and the result showed that all (10) isolate were related to (Eltor biotypes) .Also, the susceptibility test towards eight antibiotics were carried  out .

Results shows that  ciprofloxacin , Norfloxacin, Erythromycin, Ampicillin,  ceftriaxone  and Amikacin were the most effective

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Mar 01 2026
Journal Name
Iraqi Journal Of Biotechnology
Detection of acrAB, TolC, mdtk genes and biofilm forming in Klebsiella pneumoniae isolated from different cases
...Show More Authors

Publication Date
Tue Feb 01 2011
Journal Name
Iop Conference Series: Materials Science And Engineering
Contour extraction of echocardiographic images based on pre-processing
...Show More Authors

In this work we present a technique to extract the heart contours from noisy echocardiograph images. Our technique is based on improving the image before applying contours detection to reduce heavy noise and get better image quality. To perform that, we combine many pre-processing techniques (filtering, morphological operations, and contrast adjustment) to avoid unclear edges and enhance low contrast of echocardiograph images, after implementing these techniques we can get legible detection for heart boundaries and valves movement by traditional edge detection methods.

View Publication Preview PDF
Scopus (2)
Scopus Clarivate Crossref
Publication Date
Sun Feb 01 2015
Journal Name
Journal Of Engineering
Desulfurization of Diesel Fuel by Oxidation and Solvent Extraction
...Show More Authors

This research presents a study in ultra-desulfurization of diesel fuel produced from conventional hydro desulfurization process, using oxidation and solvent extraction techniques. Dibenzothiophene (DBT) was the organosulfur compound that had been detected in sulfur removal. The oxidation process used hydrogen peroxide as an oxidant and acetic acid as homogeneous catalyst . The solvent extraction process used acetonitrile (ACN) and N-methyl – 2 - pyrrolidone (NMP) as  extractants . Also the effect of five parameters (stirring speed :150 , 250 , 350 , and 450) rpm, temperature (30 , 40 , 45 , and 50) oC, oxidant/simulated diesel fuel ratio (0.5 , 0.75 , 1 , and 1.5) , catalyst/oxidant ratio(0.125,0.25,0.5

... Show More
View Publication Preview PDF
Publication Date
Wed May 07 2025
Journal Name
Microbes And Infectious Diseases
Antibacterial activity of mentha piperita extraction against uropathogenic bacteria
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Sun Dec 09 2018
Journal Name
Baghdad Science Journal
New Spectrophotometric Estimation and Cloud Point Extraction of Cefdinir
...Show More Authors

A sensitive spectrophotometric method was developed for the estimation of cefdinir (CFD), a cephalosporin species. This study involves two methods, and the first method includes the preparing of azo dye by the reaction of CFD diazonium salt with 4-Tert-Butylphenol (4-TBP) and 2-Naphthol (2-NPT) in alkaline medium, which shows colored dyes measured at λmax 490 and 535 nm, respectively. Beer's law was obeyed along the concentration range of (3-100) μg.ml-1. The limits of detection were 0.246, 0.447 μg.ml-1 and molar absorptivities were 0.6129×104, 0.3361×104 L.mol-1cm-1 for (CFD-4-TBP) and (CFD-2-NPT), respectively. The second method includes preconcentration for cefdinir dyes by using cloud point extraction in the presence of Triton

... Show More
View Publication Preview PDF
Scopus (6)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Fri Dec 31 2021
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
ADSORPTION POTENTIAL FOR A MIXTURE OF CHEMICALLY AND THERMALLY TREATED CLAYS TO REMOVE ORANGE G DYE FROM WASTE-WATER: ADSORPTION POTENTIAL FOR A MIXTURE OF CHEMICALLY AND THERMALLY TREATED CLAYS TO REMOVE ORANGE G DYE FROM WASTE-WATER
...Show More Authors

This study examined the adsorption behavior of anionic dye (orange G) from aqueous solution onto the raw and activated a mixture of illite, kaolinite and chlorite clays from area of Zorbatiya (east of Iraq).The chemical treatment involved alkali and acid activation. The alkali activation obtained by treated the raw clay (RC) with 5M NaOH (ACSO) and the acid activation founded by treated it with 0.25M HCl (ACH) and 0.25M  (ACS). The thermal treatment carried out by calcination the produce activated clay at 750oC for acid activation and 105oC for alkali activation. Batch

... Show More
View Publication Preview PDF
Publication Date
Thu Sep 30 2004
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Control of Calcium Scale and Corrosion of Medical City Cooling Water System using Sulfuric Acid
...Show More Authors

View Publication Preview PDF
Publication Date
Sun Jun 01 2014
Journal Name
Baghdad Science Journal
The effect of using magnetized water on the percentage of cement in the Concrete mixture
...Show More Authors

This research studied the effect of magnetized water in concrete preparation and its effect on the presenting of cement in concrete mixtures also to find the ability of reducing the amount of cement in preparing one cubic meter, this is not exceed than 10% in one mixture , The experiments showed the preparation of standard cubes from the concrete which was used two kind of water magnetized water which was prepared by passing the tap water through the systems of different magnetic strength in terms of (6000,9000) Gauss and the ordinary water . The velocity of water through the magnetic field, which gives us the highest value for the compressive strength, was up to 1m/sec. to determine the best magnetic intensity, we examined The comp

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Jun 01 2012
Journal Name
The Journal Of Engineering Research [tjer]
Thermal Performance of Solar Hot Water Systems Using a Flat Plate Collector of Accelerated Risers
...Show More Authors

 This study focuses on a comparison of the performance of two similar locally-fabricated solar water heaters. One of the collectors features a new design for accelerated absorber; its risers are made of converging ducts whose exit area is half that of the entrance. The other collector is a conventional absorber, with risers of the same cross sectional area along its length. Each collector is the primary part of an indirect thermosyphon circulation solar hot water system. Both collectors face south with a fixed tilt angle of 33.3

View Publication
Scopus (11)
Crossref (3)
Scopus Crossref