Performance Estimation of Heat Exchanger Operates By Evaporative Cooling Manner
...Show More Authors

        In this study the design and installation of evaporative air cooler was carried out using completely outdoor air (fresh air) according to two stage evaporative cooling principle. The laboratory equipment was installed by designing and manufacturing a cross flow plate heat exchanger, where aluminum plates used for this purpose with dimensions (50 × 30 × 40 cm). The surfaces of heat exchanger were covered by sawdust from wetted channels side, to increase the percentage of wetting these surfaces and hence improve the performance and efficiency of air cooler.

        An experimental study was carried out to estimate the performance of cooling system, where some of the dominant effective parameters were studied like air flow rate and flow rate and effect the static pressure drop of air and the heat transfer of performance .Air flow rate was ranged between (142.90 to 1461.50 m3 / hr) and water flow rate was varied from (144 L / hr) to (1050 L / hr).

        The experimental results showed that the optimum flow rate of air prepared by the air cooler is (824.7 m3 / hr), As it to be seen from the study that treating the heat exchanger surfaces by sawdust improves the air cooler efficiency about (10 %), but in the other hand leads to increase the static pressure drop in proportion (21%) approximately, and hence increase consumed power about (9 %).The results also show the air cooler can not be used in regions that have moisture content accedes (11.90 g moisture/kg dry air).

 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Sep 30 2022
Journal Name
Iraqi Geological Journal
Estimation of Initial Oil in Place for Buzurgan Oil Field by Using Volumetric Method and Reservoir Simulation Method
...Show More Authors

The estimation of the initial oil in place is a crucial topic in the period of exploration, appraisal, and development of the reservoir. In the current work, two conventional methods were used to determine the Initial Oil in Place. These two methods are a volumetric method and a reservoir simulation method. Moreover, each method requires a type of data whereet al the volumetric method depends on geological, core, well log and petrophysical properties data while the reservoir simulation method also needs capillary pressure versus water saturation, fluid production and static pressure data for all active wells at the Mishrif reservoir. The petrophysical properties for the studied reservoir is calculated using neural network technique

... Show More
View Publication
Scopus (12)
Scopus Crossref
Publication Date
Mon Jul 10 2023
Journal Name
Journal Of Engineering
Theoretical Evaluation of Solar Assisted Desiccant Cooling System for a Small Meeting-Hall
...Show More Authors

The performance of a solar assisted desiccant cooling system for a meeting-hall located in the College of Engineering/University of Baghdad was evaluated theoretically. The system was composed of four components; a solar air heater, a desiccant dehumidifier, a heat exchanger and an evaporative cooler. A computer simulation was developed by using MATLAB to assess the effect of various design and operating conditions on the performance of the system and its components. The actual weather data on recommended days were used to assess the load variation and the system performance during those days. The radiant time series method (RTS) was used to evaluate the hourly variation of the cooling load. Four operation modes were employed for perform

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Dec 30 2013
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Corrosion Inhibition of Galvanic Couple Copper Alloy/Mild Steel in Cooling Water System
...Show More Authors

The driving idea for the present work was to combine the effect of polyvinyl alcohol (PVA) as corrosion inhibitor with the distance between the anodic and cathodic elements of the galvanic cell, beside their area ratio, in scope of synergistic suppression of galvanic corrosion on Cu/Fe model couple, using weight loss method. The performance affecting galvanic corrosion process has been tested for three major factors affect the process:
1. Four PVA inhibitor concentrations were selected to be (0, 1000, 4000 and 7000 ppm) in simulated cooling water.
2. Two cathode: anode area ratios as 1:1 and 2.4:1.
3. Two distances apart cathode – anode as 3 and 7 cm.
Maximum corrosion inhibition achieved was 86% which indicates that increa

... Show More
View Publication Preview PDF
Publication Date
Thu Nov 21 2013
Journal Name
المؤتمر العلمي الدولي الرابع لاتحاد الاحصائيين العرب / بغداد
Estimating Fertility Rates in Iraq by using (Lee-Carter) Model And Forecasting for the Period (2012_2031)
...Show More Authors

A large number of researchers had attempted to identify the pattern of the functional relationship between fertility from a side and economic and social characteristics of the population from another, with the strength of effect of each. So, this research aims to monitor and analyze changes in the level of fertility temporally and spatially in recent decades, in addition to estimating fertility levels in Iraq for the period (1977-2011) and then make forecasting to the level of fertility in Iraq at the national level (except for the Kurdistan region), and for the period of (2012-2031). To achieve this goal has been the use of the Lee-Carter model to estimate fertility rates and predictable as well. As this is the form often has been familiar

... Show More
Preview PDF
Publication Date
Sun Oct 21 2018
Journal Name
Journal Of Planner And Development
توظيف العمارة المعاصرة في التقليل من الاحتباس الحراري
...Show More Authors

View Publication Preview PDF
Publication Date
Thu Jan 01 2015
Journal Name
Journal Of Engineering
Experimental Study of the effect of closed cavity wall on buildings cooling loads saving
...Show More Authors

The experimental study showed the use of closed cavity wall (the thickness of the cavity 5cm) made a percentage reduction in the cooling load caused by heat gain from the wall by (21.5 %) compared with the conventional wall. also the thermal resistance of the closed cavity was an average (0.2 m2.oC/W).

The experimental results of the study showed that the use of closed cavity wall reduced the average temperature of the inner surface of the wall during the day, and that the reduction was an average (0.45 oC)  when compared with the conventional wall , as well as the use of closed cavity wall reduced the temperature difference range of the inner surface of the wall during the day, and that the

... Show More
View Publication
Publication Date
Thu Dec 01 2011
Journal Name
Journal Of Engineering
EFFECT OF COOLING RATE ON MECHANICAL PROPERTIES OF EUTECTIC AND HYPOEUTECTIC Al-Si ALLOYS
...Show More Authors

In this research the effect of cooling rate and mold type on mechanical properties of the eutectic
and hypoeutectic (Al-Si) alloys has been studied. The alloys used in this research work were (Al- 12.6%Si
alloy) and (Al- 7%Si alloy).The two alloys have been melted and poured in two types of molds with
different cooling rates. One of them was a sand mold and the other was metal mold. Mechanical tests
(hardness, tensile test and impact test) were carried out on the specimens. Also the metallographic
examination was performed.
It has been found that the values of hardness for the alloys(Al-12.6%Si and Al-7%Si) which poured in
metal mold is greater than the values of hardness for the same alloy when it poured in a heated

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Thu Dec 01 2016
Journal Name
Journal Of Economics And Administrative Sciences
The role of my style (CPM / PERT) in enhancing the performance of construction projectsAn Empirical Study in the Department of projects in the office of the province of Baghdad
...Show More Authors

Abstract

This study was to demonstrate the role-use planning scientific methods is disabled and little used in the planning and follow-up construction of vital projects in the province of Baghdad, including network planning methods, in order to find the optimal time to finish the project in light of the resources available and the budget set for it, in the current research has been used the most prominent network planning methods and two stylistic (CPM / PERT), was the application of the critical path method on standard-design school project (traditional) to draw Action Network according to confirmed times for the activities of the project and account his Crashing time , It was Pert technique applied to the project hemato

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Aug 01 2016
Journal Name
Journal Of Economics And Administrative Sciences
The Role of Moral Intelligence of Internal Auditors in Support of the Performance of Internal Audit Process - Study for Opinions of a Sample of Internal Auditors in Iraq
...Show More Authors

Abstract

      The  aim of  the research to define the concept of moral intelligence and its dimensions and its relationship to some personal characteristics with the internal auditors and identify the importance of the employment of moral intelligence dimensions of (empathy, conscience, self- control, respect, kindness, tolerance, fairness) in the internal audit and the extent of support for the performance of the internal audit process in light of these dimensions. And that by answering the following question : Is there a role for moral intelligence  of  internal auditors in support the performance of internal audit process ? How are employ these dimensions i

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Oct 01 2020
Journal Name
Journal Of Energy Storage
Improved melting of latent heat storage via porous medium and uniform Joule heat generation
...Show More Authors

View Publication
Scopus (62)
Crossref (55)
Scopus Clarivate Crossref