Preferred Language
Articles
/
alkej-486
'Influence of Draft Tube Diameter on Operation Behavior of Air Lift Loop Reactors
...Show More Authors

The ratio of draft tube to reactor diameters is of decisive importance for the operation behavior of air lift loop reactors. The influence of draft tube geometry was investigated with respect to oxygen mass transfer and mixing time. The diameter ratio was varied between 0.33 and 0.80. The measurements were performed in two loop reactors with liquid capacities of 11.775 and 26.49 liters using aqueous with solutions of different coalescence behavior. The results show that there is no single diameter ratio which would produce most favorable conditions for the two process parameters. With respect to the more important requirements of aerobic cultures, i.e high oxygen mass transfer and efficient mixing, a diameter ratio between 0.5 and 0.6 is recommended. If high liquid velocities in the draft tube are required a ratio of 0.6 should be used.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Sep 30 2019
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Certain Assessment of Using MWCNT Nps in Drilling Fluid to Mitigate Stick-Slip Problem during Drilling Operation System
...Show More Authors

   Stick- slip is the continuous stopping& release of the Bit/BHA due to the irregular down-hole rotation prompted by the existing relationship between the friction torque and the torque applied from the surface to free the bit.

   Friction coefficient between BHA and wellbore is the main player of stick slip amount, which can be mitigated by support a good lubricators as additives in drilling mud.

   Mathematical (or empirical) solves should be done through adjusting all parameters which supposed to reduce stick- slip as low as possible using different models, one of the main parameters is drilling mud. As per Nanoparticles drilling fluid is a new technology that offers high performance

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Mon Oct 01 2018
Journal Name
Journal Of Petroleum Science And Engineering
Operation of a MEG pilot regeneration system for organic acid and alkalinity removal during MDEA to FFCI switchover
...Show More Authors

View Publication
Scopus (14)
Crossref (13)
Scopus Clarivate Crossref
Publication Date
Sun Sep 01 2019
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
Measuring the Social Responsibility and its Impact on the Financial Performance of Banks: Applied Research in the Iraqi National Bank
...Show More Authors

The objective of the research is to measure the impact of social responsibility on the financial performance of the National Bank of Iraq for the period from 2014 to 2016 (3 years) through discussing and analyzing the level of practice of the Bank of Baghdad for social responsibility and the impact on their financial performance during the period. To measure the independent variable (CSR), the researcher used the CSR Disclosure Index and relied on the ROA as an indicator to measure the dependent variable (financial performance). The results of the research showed the main hypothesis of the research, which states that the social responsibility of the banks has no significant impact on the financial performance. In relation to the disclosu

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Jan 19 2022
Journal Name
Asian Journal Of Water, Environment And Pollution
Air Pollution: A Study of Its Concept, Causes, Sources and Effects
...Show More Authors

Air pollution is very important topic for those interested in studying the environment because of its importance and the damage caused by it to human, animal and plant life. This research addresses the concept of air pollution, its causes, and its danger, and sheds light on the influence of climate elements on environmental pollution and the effect of temperature, rain, humidity, wind direction and speed, and atmospheric pressure on the increase or decrease of air pollution. This research discusses the sources of air pollution, including natural ones, including dust, smoke resulting from fires, erupting volcanoes, and others, including those resulting from human uses such as the use of fuel and others. The research addressed the dam

... Show More
View Publication
Scopus (6)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Sat Mar 01 2014
Journal Name
Renewable Energy
Field study of various air based photovoltaic/thermal hybrid solar collectors
...Show More Authors

In the present work a comparative study for thermal and electrical performance of different hybrid photovoltaic/thermal collectors designs for Iraq climate conditions have been carried out. Four different types of air based hybrid PV/T collectors have been manufactured and tested. Three collectors consist of four main parts namely, channel duct, glass cover, axial fan to circulate air and two PV panels in parallel connection. The measured parameters are, the temperature of the upper and the lower surfaces of the PV panels, air temperature along the collector, air flow rate, pressure drop, power produced by solar cell, and climate conditions such as wind speed, solar radiation and ambient temperature. The thermal and hydraulic performances o

... Show More
View Publication
Scopus (123)
Crossref (111)
Scopus Crossref
Publication Date
Fri Jul 01 2022
Journal Name
Journal Of Engineering
Conjugate Heat Transfer of Laminar Air Flow in Rectangular Mini Channel
...Show More Authors

Conjugate heat transfer has significant implications on heat transfer characteristics, particularly in thick wall applications and small diameter pipes. In this study, a three-dimensional numerical investigation was carried out using commercial CFD software “ANSYS FLUENT” to study the influence of conjugate heat transfer of laminar flow in mini channels at constant heat flux wall conditions. Two parameters were studied and analyzed: the wall thickness and thermal conductivity and their effect on heat transfer characteristics such as temperature profile and Nusselt number. Thermal conductivity of (0.25, 10, 202, and 387) W/m2C and wall thickness of (1, 5, and 50) mm were used for a channel of (1*2) mm cross

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Dec 30 2007
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Catalytic Wet Air Oxidation of Phenol in a Trickle Bed Reactor
...Show More Authors

Catalytic wet air oxidation of aqueous phenol solution was studied in a pilot plant trickle bed reactor using copperoxide catalyst supported on alumina and silica. Catalysts were prepared by impregnating method. Effect of feed solutionpH (5.9, 7.3, and 9.2), gas flow rate (20%, 50%, 80%, and 100%), WHSV (1, 2, and 3 h-1), temperature (120°C, 140°C,and 160°C), oxygen partial pressure (6, 9, 12 bar), and initial phenol concentration (1, 2, and 4 g/l).Generally, theperformance of the catalysts was better when the pH of feed solution was increased. The catalysts deactivation is relatedto the dissolution of the metal oxides from the catalyst surface due to the acidic conditions. Phenol oxidation reactionwas strongly affected by WHSV,

... Show More
View Publication
Crossref (2)
Crossref
Publication Date
Sun Sep 04 2011
Journal Name
Baghdad Science Journal
Pulse Profile Rule in Laser Heating of Opaque Targets in Air
...Show More Authors

A theoretical model is developed to determine time evolution of temperature at the surface of an opaque target placed in air for cases characterized by the formation of laser supported absorption waves (LSAW) plasmas. The model takes into account the power temporal variation throughout an incident laser pulse, (i.e. pulse shape, or simply: pulse profile).
Three proposed profiles are employed and results are compared with the square pulse approximation of a constant power.

View Publication Preview PDF
Crossref
Publication Date
Sun Dec 30 2007
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Catalytic Wet Air Oxidation of Phenol in a Trickle Bed Reactor
...Show More Authors

Catalytic wet air oxidation of aqueous phenol solution was studied in a pilot plant trickle bed reactor using copper
oxide catalyst supported on alumina and silica. Catalysts were prepared by impregnating method. Effect of feed solution
pH (5.9, 7.3, and 9.2), gas flow rate (20%, 50%, 80%, and 100%), WHSV (1, 2, and 3 h-1), temperature (120°C, 140°C,
and 160°C), oxygen partial pressure (6, 9, 12 bar), and initial phenol concentration (1, 2, and 4 g/l).Generally, the
performance of the catalysts was better when the pH of feed solution was increased. The catalysts deactivation is related
to the dissolution of the metal oxides from the catalyst surface due to the acidic conditions. Phenol oxidation reaction
was strongly

... Show More
View Publication Preview PDF
Publication Date
Wed Jun 01 2022
Journal Name
Journal Of Engineering Science And Technology
THERMAL PERFORMANCE OF MULTIPLE- PASS SOLAR AIR HEATER WITH PIN FINS
...Show More Authors

Scopus (8)
Scopus