Preferred Language
Articles
/
alkej-428
Removal of Dissolved Trivalent Chromium Ions from Contaminated Wastewater using Locally Available Raw Scrap Iron-Aluminum Waste
...Show More Authors

The present study is to investigate the possibility of using wastes in the form of scrap iron (ZVI) and/ or aluminum ZVAI for the detention and immobilization of the chromium ions in simulated wastewater. Different batch equilibrium parameters such as contact time (0-250) min, sorbent dose (2-8 g ZVI/100 mL and 0.2-1 g ZVAI/100 mL), initial pH (3-6), initial pollutant concentration of 50 mg/L, and speed of agitation (0-250) rpm were investigated. Maximum contaminant removal efficiency corresponding to (96 %) at 250 min contact time, 1g ZVAI/ 6g ZVI sorbent mass ratio, pH 5.5, pollutant concentration of 50 mg/L initially, and 250 rpm agitation speed were obtained.

The best isotherm model for the batch single Cr(III) uptake by ZVI and / or ZVAI sorbent was found to follow Langmuir (I) with corresponding R2greater than 0.9115. Kinetics data for the sorption of Cr(III) onto ZVAI/ZVI mixture and due to the good agreement between the fitted and the experimental results; the data was found to obey the pseudo second order model at which the chemisorptions mechanism was the most dominant in the sorption process. Scanning electron microscopy (SEM) for the ZVI and ZVAI has revealed highly surface changes and saturation by contaminant and apparent pores blockage that hindered and ceased the sorption process.

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Aug 07 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Science
Synthesis and Characterization of Tetradentate Complexes Type N2O2 From the Reaction of 2-Hydroxy -1, 2-Diphynel-Ethanone Oxime [H2L] With Mn II, Fe II, Co II, Ni II, Cu II and Hg II Ions
...Show More Authors

Tetradentate complexes type [M (HL) 2] were prepared from the reaction of 2-hydroxy -1, 2-diphynel-ethanone oxime [H2L] and KOH with ( Mn II, Fe II, Co II, Ni II , Cu II and Hg II ), in methanol with (2:1) metal: ligand ratio. The general formula for Cu II and Mn II complexes are [M (HL) 2 Cl.H2O] K, for Co II [Co (HL) 2. H2O] and [M (HL) 2] for the rest of complexes. All compounds were characterised by spectroscopic methods, I.R, U.V-Vis, H.P.L.C, atomic absorption and conductivity measurements chloride content. From the data of these measurements, the proposed molecular structures for Fe II and Hg II complexes are tetrahedrals, while Mn II and Cu II complexes are octahedrals, Ni II complex adopting square planar structure and the complex

... Show More
Publication Date
Mon Feb 04 2019
Journal Name
Journal Of The College Of Education For Women
Determination Of Sedimentary Environment Of Al-koot-Betera Project Soils From South- Mesopotamia Plain
...Show More Authors

Soils at Al-Koot-Btera were choosen to determine their sedimentary
environments. It is found that there are , five soil series and as mentioned :
MF11-MW9-DM97-DM57-DF95 . The five found soil series are of internal
well drained ,moderate and imperfect. Their textures vary in moderately,fine
and moderately fine.
indicating that sediments rang from poorly to very poorly sorting. Values of median
diameter Md Ø range between 4.11-7.80 Ø .The relation between the sorting
and median diameter shows that 95.24% of samples is a sedimentary
environment of aquite river , while 4.76% is aeolian sediments.
The values of meso to platy kurtic of most horizon materials rang
between 0.67-1.26 Ø .That is to say the samples

... Show More
View Publication Preview PDF
Publication Date
Fri Mar 01 2013
Journal Name
Diyala Journal Of Engineering Sciences
Kinetic of Atropine Pertraction from the Seeds of Datura Metel Linn Plant Using Liquidliquid Membrane Technique
...Show More Authors

The kinetic of atropine pertraction from seeds of Datura Metel Linn plant was studied. Diisopropyl ether, n-hexane and n-heptane were used as membranes for atropine recovery. The effect of speed of agitation and time in the range of 200-300 rpm and 0-3.5h, respectively were studied using the proposed membranes. The pertraction experiments were carried outs in a batch laboratory unit. The liquid-liquid pertraction was found to be very suitable for atropine recovery from its liquid extracts of Datura Metel seeds. A high purity (94-96%) can be obtained in the receiver phase. The pertraction process was found to be very selective for atropine recovery with diisopropyl ether membrane. As the speed of agitation increases the efficiency of pertrac

... Show More
View Publication
Crossref
Publication Date
Fri Sep 30 2016
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Experimental Study and Mathematical Modelling of Zinc Removal by Reverse Osmosis Membranes
...Show More Authors

In this study, aromatic polyamide reverse osmosis membranes were used to remove zinc ions from electroplating wastewater. Influence of different operating conditions such as time, zinc concentration and pressure on reverse osmosis process efficiency was studied. The experimental results showed, concentration of zinc in permeate increase with increases of time from 0 to 70 min, and flux of water through membrane decline with time. While, the concentrations of zinc in permeate increase with the increase in feed zinc concentration (10–300 mg/l), flux decrease with the increment of feed concentration. The raise of pressure from 1 to 4 bar, the zinc concentration decreases and the flux increase. The highest recovery percentage was found is 54.

... Show More
Preview PDF
Publication Date
Fri Sep 30 2016
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Experimental Study and Mathematical Modelling of Zinc Removal by Reverse Osmosis Membranes
...Show More Authors

In this study, aromatic polyamide reverse osmosis membranes were used to remove zinc ions from electroplating wastewater. Influence of different operating conditions such as time, zinc concentration and pressure on reverse osmosis process efficiency was studied.  The experimental results showed, concentration of zinc in permeate increase with increases of time from 0 to 70 min, and flux of water through membrane decline with time. While, the concentrations of zinc in permeate increase with the increase in feed zinc concentration (10–300 mg/l), flux decrease with the increment of feed concentration. The raise of pressure from 1 to 4 bar, the zinc concentration decreases and the flux increase. The highest recovery percentage was fou

... Show More
View Publication Preview PDF
Publication Date
Sun Jul 09 2023
Journal Name
Journal Of Engineering
Study the Application of Ultrasonic Technology for Phenol Removal in Petroleum Industry
...Show More Authors

In this study, the sonochemical degradation of phenol in water was investigated using two types of ultrasonic wave generators; 20 kHz ultrasonic processor and 40 kHz ultrasonic cleaner bath. Mineralization rates were determined as a function of phenol concentration, contact time, pH, power density, and type of ultrasonic generator. Results revealed that sonochemical degradation of the phenol conversion was enhanced at increased applied power densities and acidic conditions. At 10 mg/L initial concentration of phenol, pH 7, and applied power density of 3000 W/L, the maximum removal efficiency of phenol was 93% using ultrasonic processor at 2h contact time. Whereby, it was 87% using and ultrasonic cleaner bath at 16h contact time and 150 W

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Jun 30 2020
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Process Optimization Study of Pb(II) Removal by Bulk Liquid Membrane (BLM)
...Show More Authors

   Box-Wilson experimental design method was employed to optimized lead ions removal efficiency by bulk liquid membrane (BLM) method. The optimization procedure was primarily based on four impartial relevant parameters: pH of feed phase (4-6), pH of stripping phase (9-11), carrier concentration TBP (5-10) %, and initial metal concentration (60-120 ppm). maximum recovery efficiency of lead ions is 83.852% was virtually done following thirty one-of-a-kind experimental runs, as exact through 24-Central Composite Design (CCD). The best values for the aforementioned four parameters, corresponding to the most restoration efficiency were: 5, 10, 7.5% (v/v), and 90 mg/l, respectively. The obtained experimental data had been

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Tue Mar 01 2022
Journal Name
Journal Of Engineering
Performance Evaluation the Turbidity Removal Efficiency of AL-Muthana Water Treatment Plant
...Show More Authors

Turbidity is a visual property of water that expresses the amount of suspended substances in the water. Its presence in quantities more significant than the permissible limit makes the water undrinkable and reduces the effectiveness of disinfectants in treating pathogens. On this basis, turbidity is used as a basic indicator for measuring water quality. This study aims to evaluate the removal efficiency of AL- Muthanna WTP. Water turbidity was used as a basic parameter in the evaluation, using performance improvement evaluation and data from previous years (2016 to 2020). The average raw water turbidity was 26.7 NTU, with a minimum of 14 NTU, with a maximum of 48 NTU. Water turbidity value for 95% of settling daily readi

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Tue Mar 01 2022
Journal Name
Journal Of Engineering
Performance Evaluation the Turbidity Removal Efficiency of AL-Muthana Water Treatment Plant
...Show More Authors

Turbidity is a visual property of water that expresses the amount of suspended substances in the water. Its presence in quantities more significant than the permissible limit makes the water undrinkable and reduces the effectiveness of disinfectants in treating pathogens. On this basis, turbidity is used as a basic indicator for measuring water quality. This study aims to evaluate the removal efficiency of AL- Muthanna WTP. Water turbidity was used as a basic parameter in the evaluation, using performance improvement evaluation and data from previous years (2016 to 2020). The average raw water turbidity was 26.7 NTU, with a minimum of 14 NTU, with a maximum of 48 NTU. Water turbidity value for 95% of settling daily reading data was

... Show More
Crossref (6)
Crossref
Publication Date
Mon Jan 01 2018
Journal Name
World Journal Of Dentistry
In vitro Remineralization of Caries-affected Dentin after Selective Carious Tissue Removal
...Show More Authors

View Publication Preview PDF
Scopus (12)
Scopus