In the present work, the pollutants of the municipal wastewater are reduced using Chlorella vulgaris microalgae. The pollutants that were treated are: Total organic carbon (TOC), Chemical oxygen demand (COD), Nitrate (NO3), and Phosphate (PO4). Firstly, the treatment was achieved at atmospheric conditions (Temperature = 25oC), pH 7 with time (1 – 48 h). To study the effect of other microorganisms on the reduction of pollutants, sterilized wastewater and unsterilized wastewater were used for two types of packing (cylindrical plastic and cubic polystyrene) as well as algae's broth (without packing), where the microalgae are grown on the packing then transported to the wastewater for treatment. The results showed that the other microorganism in unsterilized wastewater can slightly contribute in the treatment. Packing of cylindrical plastic is more effective than the cubic polystyrene, and microalgae's broth gives better results than the two types of packing. The treatment in the first hours was performed quickly while in the last hours, it was very slow. Then, the following parameters in the range of (temperature: 20 – 35o) pH (5 – 8), volume ratio of wastewater to microalgae's broth (1 – 2.5) were studied for sterilized wastewater and constant treatment time equal to 48 h. The results showed that the maximum reduction of pollutants are: TOC = 92.3%, NO3 = 65.2%, PO4 = 93.2% at T = 35oC, pH 8, and (wastewater/algae broth) ratio = 1, and COD = 85.6% at T = 30oC, pH 7, and (wastewater/ algae broth) ratio = 1. The temperature and pH have little effect on the reduction of pollutants compared with the wastewater/algae broth ratio. The adsorption isotherm for pollutant was also studied for three types of isotherm; linear, Freundlich, and Langmuir. The results showed that the treated pollutants are the Langmiur adsorption isotherm.
Air pollution is considered one of the major environmental problems that contain many challenges and difficulties facing most countries of the world, including Iraq. The problem has emerged widely with the emergence of the industrial revolution in the world and the tremendous increase in the population and the increase in the number of transportation and its development in addition to excavation, maintenance and work Construction and weather fluctuations, such as dust and sandstorms, pollution resulting from oil refining, extraction, diversion and other processes that cause pollution, and the start of the world using methods that limit the volume of environmental pollution. The most prominent of these methods is the imposition of
... Show MoreDiarrhea is a real disease in childhood which could cause death. Therefore, this study was conducted to isolate Salmonella from 350 stool samples taken from children under five years in age, suffering from diarrhea during the period from March 2019 to March 2020 in Tikrit city / Iraq. The results showed the possibility to isolate ten isolates of Salmonella enterica subsp. Enterica, an infection rate, represents 2.875% of the total rate of patients who suffer from diarrhea. The virulence genes were investigated for ten isolates of S. enterica subsp. enterica, the result is that all isolates possessed the genes stn, invA, lpfA with an appearance percentage of 100%, whi
... Show MoreAbstract
This research aims to evaluate the application of the inspectors general of global indicators offices according to the axles (leadership, strategy and planning, employees, partners and resources, process management) and through the assumption main research which states that (there is an application for global indicators to evaluate performance in the offices of the ministries under study) which are subdivided into five sub-hypotheses according to the classification and division of the five axes of the checklist.
The researchers have taken refuge in the process of assessing the performance of the check list which included global i
... Show MoreThe basic objective of the research is to study the quality of the water flow service in the Directorate of Karbala sewage and how to improve it after identifying the deviations of the processes and the final product and then providing the possible solutions in addressing the causes of the deviations and the associated quality gaps. A number of quality tools were used and applied to all data Stations with areas and activities related to the drainage of rainwater, as the research community determines the stations of lifting rainwater in the Directorate of the streams of Karbala holy, and the station was chosen Western station to apply the non-random sampling method intended after meeting a number of. It is one of the largest and m
... Show MoreIn the present study, MIG welding is carried out on low carbon steel type (AISI 1015) by using electrode ER308L of 1.5mm diameter with direct current straight polarity (DCSP). The joint geometry is of a single V-butt joint with one pass welding stroke for different plate thicknesses of 6, 8, and 10 mm. In welding experiments, AISI 1015 plates with dimensions of 200×100mm and edge angle of 60o from both sides are utilized. In this work, three main parameters related to MIG welding process are investigated, which are welding current, welding speed, heat input and plate thickness, and to achieve that three groups of plates are employed each one consists of three plates. The results indicate that increasing the weld heat input (t
... Show MoreEfficient management of treated sewage effluents protects the environment and reuse of municipal, industrial, agricultural and recreational as compensation for water shortages as a second source of water. This study was conducted to investigate the overall performance and evaluate the effluent quality from Al- Rustamiya sewage treatment plant (STP), Baghdad, Iraq by determining the effluent quality index (EQI). This assessment included daily records of major influent and effluent sewage parameters that were obtained from the municipal sewage plant laboratory recorded from January 2011 to December 2018. The result showed that the treated sewage effluent quality from STP was within the Iraqi quality standards (IQS) for disposal and t
... Show MoreCombining ultrasonic irradiation and the Fenton process as a sono-Fenton process, the chemical oxygen demand (COD) in refinery wastewater was successfully eliminated using response surface methodology (RSM) with central composite design (CCD). The impact of two main influential operational parameters (iron dosage and reaction time) on the COD removal from wastewater generated by an Iraqi petroleum refinery facility was explored. Removal of 85.81% was attained under the optimal conditions of 21 minutes and 0.289 mM of concentration. Additionally, the results revealed that the concentration of has the highest effect on the COD elimination, followed by reaction time. The high R2 value (96.40%) validated the strong fit of the mo
... Show MoreCoagulation is the most important process in drinking water treatment. Alum coagulant increases the aluminum residuals, which have been linked in many studies to Alzheimer's disease. Therefore, it is very important to use it with the very optimal dose. In this paper, four sets of experiments were done to determine the relationship between raw water characteristics: turbidity, pH, alkalinity, temperature, and optimum doses of alum [ .14 O] to form a mathematical equation that could replace the need for jar test experiments. The experiments were performed under different conditions and under different seasonal circumstances. The optimal dose in every set was determined, and used to build a gene expression model (GEP). The models were co
... Show MoreThe inhibitor property of curcuma longa L. extract in different concentrations of simulated refinery wastewater (0.05% - 2% wt) and at various temperatures (30, 35 and 40 ˚C) was investigated using weight loss method. The results showed that the presence of about 1.2 % (v/v) of curcuma extract gave about 84% inhibition indicating its effectiveness on mild steel corrosion in simulated refinery wastewater, besides the adsorption process on the mild steal surface obeyed the Langmuir adsorption isotherm.