In IRAQ, the air conditioners are the principal cause of high electrical demand. In summer, the outer temperature sometimes exceeds 500C which significantly effects on the A/C system performance and power consumed. In the present work, the improvement in mechanical and electrical performance of split A/C system is investigated experimentally and analytically. In this paper, performance and energy saving enhancement of a split-A/C system was experimentally investigated to be efficiently compatible with elevated temperature weathers. This improvement is accomplished via Smart Control System integrate with Proportional-Integral- Differential PID algorithm. The PIC16F877A micro-controller has been programmed with the PID and PWM codes to control the speed of the proposed DC condenser fan over wide range of speed, also it has been programmed to have a smart characteristics to protect the A/C system parts as the ability to detect a refrigerant leakage, condenser fan stop, and any obstacles for the fan air flow. A comparative study between the conventional and enhanced A/C system is performed. The results show that the proposed system exhibits better performance and saves more energy than the conventional one. The Coefficient of Performance (COP) of the split- A/C system are improved by about 20.56%.
The internal observing system is considered a cornerstone for the high management in all the systems. It aims at defending the things for waste and increasing efficient and application the rules and regulations and constrictions. To easier for the high management activity in the internal observing system which in presented and practiced and to what extent can depend on it. Thus it goes to evaluate the internal observing system periodically to check the weak points in that system so as the find out the mistake, in the construction of the system or mistake, by indication of the workers. The importance of this study is represented in the need of increasing the coactivity in the internal observing system so as to be in touch with the new tre
... Show MoreAbstract
Magnetic abrasive finishing (MAF) is one of the advanced finishing processes, which produces a high level of surface quality and is primarily controlled by a magnetic field. This paper study the effect of the magnetic abrasive finishing system on the material removal rate (MRR) and surface roughness (Ra) in terms of magnetic abrasive finishing system for eight of input parameters, and three levels according to Taguchi array (L27) and using the regression model to analysis the output (results). These parameters are the (Poles geometry angle, Gap between the two magnetic poles, Grain size powder, Doze of the ferromagnetic abrasive powder, DC current, Workpiece velocity, Magnetic poles velocity, and Finishi
... Show MoreThis paper is submitted as anew approach to simulate manufacturing control & planning system to define the problem of designing control system on the needs for materials.
Production planning & control is a total and complex operation, resides in the essence of manufacturing companies operations. The successful process of production planning and control systems is critical for the staying of manufacturing organizations in markets leading to the increasing consumer competition and which dominate most of manufacturing sectors because of the market oriented economy , thus , what has happened previously , that the companies possessed a great inventory of crude material, components, and groupings and they use in flexible techni
... Show MoreThe Ant System Algorithm (ASA) is a member of the ant colony algorithms family in swarm intelligence methods (part of the Artificial Intelligence field), which is based on the behavior of ants seeking a path and a source of food in their colonies. The aim of This algorithm is to search for an optimal solution for Combinational Optimization Problems (COP) for which is extremely difficult to find solution using the classical methods like linear and non-linear programming methods.
The Ant System Algorithm was used in the management of water resources field in Iraq, specifically for Haditha dam which is one of the most important dams in Iraq. The target is to find out an efficient management system for
... Show MoreDirect field-orientation Control (DFOC) of induction motor drives without mechanical speed sensors at the motor shaft has the attractions of low cost and high reliability. To replace the sensor, information on the rotor speed and position are extracted from measured stator currents and from voltages at motor terminals. In this paper presents direct field-orientation control (DFOC) with two type of kalman filter (complete order and reduced order extended kalman filter) to estimate flux, speed, torque and position. Simulated results show how good performance for reduced order extended kalman filter over that of complete order extended kalman filter in tracking performance and reduced time of state estimation.
The luxury of the grace and the extension of the vioa of the subjects that attract two teams of opinion,
Addame
QF Faba believes that
Meet
.
And poverty is the best in human life, and others see it
And Joe titling
Grace, and not for man to suffer as long as stigmatized and
Try not to have money.
And in recent years
G
F
S
A lot of people bypassing
.
I see who says austerity in
Thou shalt not see grace
Color of and
Luxury has been promoted to the religious life of
M
A lounge
And others, and a team of worshipers to distance themselves from the mantle of turquoise,
Faleh me
I was looking at this part because I did not
.
See my opinion
Experimental tests were conducted to investigate the thermal performance (cooling effect) of water mist system consisting of 5μm volume median diameter droplets in reducing the heat gain entering a room through the roof and the west wall by reducing the outside surface temperature due to the evaporative cooling effect during the hot dry summer of Baghdad/Iraq. The test period
was Fifty one days during the months May, June, and July 2012. The single test day consists of 16 test hours starting from 8:00 am to 12:00 pm. The results showed a reduction range of 1.71 to 15.5℃ of the roof outside surface temperature and 21.3 to 76.6% reduction in the daily heat flux entering the room through the roof compared with the case of not using w
The aim of this research is to measure and analyze the gap between the actual reality and the requirements of the environmental management system in the middle refineries company/refinery cycle according to ISO14001: 2015, as well as to measure the availability of a clean production strategy and test the relationship and impact between the availability of the requirements of the standard and a clean production strategy for the actual reality in the company.
The research problem was determined by the extent to which the requirements of the environmental management system are applied according to ISO14001: 2015 in the middle refineries company? To what extent are the required clean production strategies ava
... Show MoreConcentrations 25, 50 and 100 mg of nano-capsules linolenic acid and non-capsulated fatty acid for 1kg of Milk was used for yogurt manufacture. The results showed no significant differences in the ratio of titration acidity and pH values between all processed treatments at the beginning and during of period storage. The treatments was added to it coated omega-3 by nano method were the least exposed to the oxidation process from the non-capsules omega-3, And for shield of The poly lactic acid had a significant role in the protection of alpha-linolenic acid against lipolysis by the formation of a protective layer to protect the acid from the activity of lipases enzymes, and the addition of fatty acid linolenic to milk was determined the gr
... Show More