Preferred Language
Articles
/
alkej-318
Using Smart Control System to Enhancement the Split Air Conditioning System Performance
...Show More Authors

In IRAQ, the air conditioners are the principal cause of high electrical demand. In summer, the outer temperature sometimes exceeds 500C which significantly effects on the A/C system performance and power consumed. In the present work, the improvement in mechanical and electrical performance of split A/C system is investigated experimentally and analytically. In this paper, performance and energy saving enhancement of a split-A/C system was experimentally investigated to be efficiently compatible with elevated temperature weathers. This improvement is accomplished via Smart Control System integrate with Proportional-Integral- Differential PID algorithm. The PIC16F877A micro-controller has been programmed with the PID and PWM codes to control the speed of the proposed DC condenser fan over wide range of speed, also it has been programmed to have a smart characteristics to protect the A/C system parts as the ability to detect a refrigerant leakage, condenser fan stop, and any obstacles for the fan air flow. A comparative study between the conventional and enhanced A/C system is performed. The results show that the proposed system exhibits better performance and saves more energy than the conventional one. The Coefficient of Performance (COP) of the split- A/C system are improved by about 20.56%.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Nov 01 2014
Journal Name
Ibn Al-haitham Jour. For Pure & Appl. Sci.
Derivationof Mathematical Equations to Calculate the Geographical Coordinates ofUnknown Position SituatedataDistance from the Observer Position Using GPS Data
...Show More Authors

Publication Date
Tue Aug 01 2023
Journal Name
Baghdad Science Journal
Performance Evaluation of a Triple Concentric Tube Heat Exchanger Using Deionized Water and Oil-40
...Show More Authors

This study examines experimentally the performance of a horizontal triple concentric tube heat exchanger TCTHE made of copper metal using water as cooling fluid and oil-40 as hot fluid. Hot fluid enters the inner annular tube of the TCTHE in a direction at a temperature of 50, 60 and 70 oC and a flow rate of 20 l/hr. On the other hand, the cooling fluid enters the inner tube and the outer annular tube in the reverse direction (counter current flow) at a temperature of 25 oC and flow rates of 10, 15, 20, 25, 30 and 35 l/hr. The TCTHE is composed of three copper tubes with outer diameters of 34.925 mm, 22.25 mm, and 9.525 mm, and thicknesses of 1.27 mm, 1.143 mm, and 0.762 mm, respectively. TCTHE tube's length was 670

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Thu Jan 01 2015
Journal Name
Aip Conference Proceedings
Performance measurements of single server fuzzy queues with unreliable server using left and right method
...Show More Authors

The fuzzy assignment models (FAMs) have been explored by various literature to access classical values, which are more precise in our real-life accomplishment. The novelty of this paper contributed positively to a unique application of pentagonal fuzzy numbers for the evaluation of FAMs. The new method namely Pascal's triangle graded mean (PT-GM) has presented a new algorithm in accessing the critical path to solve the assignment problems (AP) based on the fuzzy objective function of minimising total cost. The results obtained have been compared to the existing methods such as, the centroid formula (CF) and centroid formula integration (CFI). It has been demonstrated that operational efficiency of this conducted method is exquisitely develo

... Show More
View Publication
Scopus (2)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Wed Apr 01 2026
Journal Name
Case Studies In Construction Materials
Performance Evaluation of Modified Hard-Grade Asphalt Binder Using Waste PVC Derived from Flex Banners
...Show More Authors

Hard-grade asphalt binders, such as AC 20–30, offer excellent resistance to permanent deformation but are inherently brittle, making them highly susceptible to fatigue and low-temperature cracking. While polymer modification addresses these issues, virgin polymers remain expensive. Despite the growing interest in recycled plastics, the rheological impact of complex waste streams, specifically polyvinyl chloride (PVC) derived from flex banners containing plasticizers, on excessively stiff binders within the complete Superpave Performance Grading (PG) framework remains critically underexplored. This study introduces a novel valorization approach by utilizing solvent-extracted flex banner waste (WPVC) as a dual-action modifier. It leverages

... Show More
View Publication
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Tue Jun 01 2021
Journal Name
Iop Conference Series: Earth And Environmental Science
Performance Evaluation of Al-Karkh Water Treatment Plant Using Model-driven and Data-Driven Models
...Show More Authors
Abstract<p>There is a great operational risk to control the day-to-day management in water treatment plants, so water companies are looking for solutions to predict how the treatment processes may be improved due to the increased pressure to remain competitive. This study focused on the mathematical modeling of water treatment processes with the primary motivation to provide tools that can be used to predict the performance of the treatment to enable better control of uncertainty and risk. This research included choosing the most important variables affecting quality standards using the correlation test. According to this test, it was found that the important parameters of raw water: Total Hardn</p> ... Show More
View Publication
Scopus (2)
Crossref (3)
Scopus Crossref
Publication Date
Mon Dec 20 2021
Journal Name
Baghdad Science Journal
Recurrent Stroke Prediction using Machine Learning Algorithms with Clinical Public Datasets: An Empirical Performance Evaluation
...Show More Authors

Recurrent strokes can be devastating, often resulting in severe disability or death. However, nearly 90% of the causes of recurrent stroke are modifiable, which means recurrent strokes can be averted by controlling risk factors, which are mainly behavioral and metabolic in nature. Thus, it shows that from the previous works that recurrent stroke prediction model could help in minimizing the possibility of getting recurrent stroke. Previous works have shown promising results in predicting first-time stroke cases with machine learning approaches. However, there are limited works on recurrent stroke prediction using machine learning methods. Hence, this work is proposed to perform an empirical analysis and to investigate machine learning al

... Show More
View Publication Preview PDF
Scopus (14)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Fri Jun 01 2012
Journal Name
The Journal Of Engineering Research [tjer]
Thermal Performance of Solar Hot Water Systems Using a Flat Plate Collector of Accelerated Risers
...Show More Authors

 This study focuses on a comparison of the performance of two similar locally-fabricated solar water heaters. One of the collectors features a new design for accelerated absorber; its risers are made of converging ducts whose exit area is half that of the entrance. The other collector is a conventional absorber, with risers of the same cross sectional area along its length. Each collector is the primary part of an indirect thermosyphon circulation solar hot water system. Both collectors face south with a fixed tilt angle of 33.3

View Publication
Scopus (11)
Crossref (3)
Scopus Crossref
Publication Date
Sun Mar 15 2020
Journal Name
Journal Of The College Of Education For Women
The Use of English as Lingua Franca in the Classes of UKM: as A Case of Study
...Show More Authors

           English has for long been one of the most widely used media of communication globally, especially in the Malaysian universities. It has been termed as a Lingua Franca because it is shared with other languages which are considered first languages by different speakers. For this reason, English as a Lingua Franca (ELF) has attracted a number of researchers to investigate its variety via other languages in various communities. The objective of this paper is therefore to establish the strategies which are employing by the international students at the National University of Malaysia/ UniversitiKebangsaan Malaysia (UKM) as an example of one of the Malaysian universities; when they e

... Show More
View Publication Preview PDF
Publication Date
Wed Nov 28 2018
Journal Name
Al-khwarizmi Engineering Journal
Effect of Using Combined Square Nozzle & winglet with Helical Tape on Thermal Characteristics in Tube Heat Exchanger
...Show More Authors

Influence of combined square nozzle with helical tape inserted in a constant heat flux tube on heat transfer enhancement for turbulent airflow for Reynolds number ranging from 7000 to 14500 were investigated experimentally. Three different pitch ratios for square nozzle (PR = 5.8, 7.7 and 11.6) according to three different numbers of square nozzle (N = 3, 4 and 5) and constant pitch ratios for helical tape were used. The results observed that the Nusselt number and friction factor for combination with winglets were found to be up to 33.8 % and 21.4 %, respectively higher than nozzle alone for pitch ratio PR=5.8. The maximum value of thermal performance for using combination with winglets was about 1.351 for pitch ratio= 5.8. Nusselt numb

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Dec 30 2023
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Selecting Optimum Dimensions for a Three-Phase Horizontal Smart Separator for Khor Mor Gas-Condensate Processing Plant
...Show More Authors

      The Khor Mor gas-condensate processing plant in Iraq is currently facing operational challenges due to foaming issues in the sweetening tower caused by high-soluble hydrocarbon liquids entering the tower. The root cause of the problem could be liquid carry-over as the separation vessels within the plant fail to remove liquid droplets from the gas phase. This study employs Aspen HYSYS v.11 software to investigate the performance of the industrial three-phase horizontal separator, Bravo #2, located upstream of the Khor Mor sweetening tower, under both current and future operational conditions. The simulation results, regarding the size distribution of liquid droplets in the gas product and the efficiency gas/liquid separation, r

... Show More
View Publication Preview PDF
Crossref (1)
Crossref