Preferred Language
Articles
/
alkej-301
Experimental Investigations Performance for (VCC) Using 2-Way (PFCV) Type (2FRE)
...Show More Authors

In modern hydraulic control systems, the trend in hydraulic power applications is to improve efficiency and performance. “Proportional valve” is generally applied to pressure, flow and directional-control valves which continuously convert a variable input signal into a smooth and proportional hydraulic output signal. It creates a variable resistance (orifice) upstream and downstream of a hydraulic actuator, and is meter in/meter out circuit and hence pressure drop, and power losses are inevitable. If velocity (position) feedback is used, flow pattern control is possible. Without aforementioned flow pattern, control is very “loose” and relies on “visual” feed back by the operator. At this point, we should examine how this valve works and how can use it in electro-hydraulic circuit designs.

In this paper, constructed and compared velocity control cylinder (VCC) by using a proportional flow control valve (PFCV) and with a fine throttle valve. With the aid of a check valve and that check valve, the proportional valve can be made to act in the “lift” direction, and the fine throttle in the “lower” direction. As with all proportional valves, there is also some hysteresis in a proportional flow control valve. The valve used in this work with a hysteresis of <±1% of  . The repetition accuracy is quoted in data sheet as < 1% of . The inferential results are good, acceptable and useful for designers which are working at hydraulic proportional field.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
Improve the performance of solar cells using new designs for pelvic center wheel Type V compound mirrors encased by Vernil glasses
...Show More Authors

Design and build a center basins new p-type four mirrors were studied its effect on all parameters evaluating the performance of the solar cell silicon in the absence of a cooling system is switched on and noted that the efficiency of the performance Hzzh cell increased from 11.94 to 21 without cooling either with cooling has increased the efficiency of the

View Publication Preview PDF
Publication Date
Wed Dec 01 2021
Journal Name
Iraqi Journal Of Physics
Effect of Deposit Au thin Layer Between Layers of Perovskite Solar Cell on Cell's Performance
...Show More Authors

The present work aims to fabricate n-i-p forward perovskite solar cell (PSC) withئ structure (FTO/ compact TiO2/ compact TiO2/ MAPbI3 Perovskite/ hole transport layer/ Au). P3HT, CuI and Spiro-OMeTAD were used as hole transport layers. A nano film of 25 nm gold layer was deposited once between the electron transport layer and the perovskite layer, then between the hole transport layer and the perovskite layer. The performance of the forward-perovskite solar cell was studied. Also, the role of each electron transport layer and the hole transport layer in the perovskite solar cell was presented. The structural, morphological and electrical properties were studied with X-ray diffractometer, field emission s

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Fri Dec 01 2023
Journal Name
Chemical Methodologies
Investigations on TiO<inf>2</inf>-NiO@In<inf>2</inf>O<inf>3</inf> Nanocomposite Thin Films (NCTFs) for Gas Sensing: Synthesis, Physical Characterization, and Detection of NO<inf>2</inf> and H<inf>2</inf>S Gas Sensors
...Show More Authors

Scopus (15)
Scopus
Publication Date
Tue Jan 01 2019
Journal Name
Association Of Arab Universities Journal Of Engineering Sciences
Experimental and numerical investigation on the behavior of reinforced reactive powder concrete two-way slabs under static load
...Show More Authors

This paper studied the behaviour of reinforced reactive powder concrete (RPC) two-way slabs under static load. The experimental program included testing three simply supported slabs of 1000 mm length, 1000 mm width, and 70 mm thickness. Tested specimens were of identical properties except their steel fibers volume ratio (0.5 %, 1 %, and 1.5 %). Static test results revealed that, increasing steel fibers volume ratio from 0.5% to 1% and from 1% to 1.5%, led to an increase in: first crack load by (32.2 % and 52.3 %), ultimate load by (36.1 % and 17.0 %), ultimate deflection by (33.6 % and 3.4 %), absorbed energy by (128 % and 20.2 %), and the ultimate strain by (1.1 % and 6.73 %). The stiffness and ductility of the specimens also increased. A

... Show More
View Publication
Publication Date
Sat Jun 01 2013
Journal Name
Journal Of Economics And Administrative Sciences
Impact of the career path requirements in determining the type of training program
...Show More Authors

The research deals with the important and modern two subject (career path and the type of training program), and tries to find identify the extent of the impact of the requirements of a career path in determining the type of training program in the Ministry of Oil.

In order to achieve the aim of the research was the formulation of the following hypothesis: the impact of the requirements of the career path a meaningful moral influence in determining the type of training program.

The survey was adopted in the search, and sample consisted of (75) people were a factor in the Oil Ministry of People's managers and officials and staff, and used the questionnaire as an es

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Dec 20 2021
Journal Name
Baghdad Science Journal
An Experimental Study of the Server-based Unfairness Solutions for the Cross-Protocol Scenario of Adaptive Streaming over HTTP/3 and HTTP/2
...Show More Authors

Since the introduction of the HTTP/3, research has focused on evaluating its influences on the existing adaptive streaming over HTTP (HAS). Among these research, due to irrelevant transport protocols, the cross-protocol unfairness between the HAS over HTTP/3 (HAS/3) and HAS over HTTP/2 (HAS/2) has caught considerable attention. It has been found that the HAS/3 clients tend to request higher bitrates than the HAS/2 clients because the transport QUIC obtains higher bandwidth for its HAS/3 clients than the TCP for its HAS/2 clients. As the problem originates from the transport layer, it is likely that the server-based unfairness solutions can help the clients overcome such a problem. Therefore, in this paper, an experimental study of the se

... Show More
View Publication Preview PDF
Scopus Clarivate Crossref
Publication Date
Sun Sep 01 2019
Journal Name
Baghdad Science Journal
Investigation of Superhydrophobic/Hydrophobic Materials Properties Using Electrospinning Technique
...Show More Authors

     The aim of this research is to study the surface alteration characteristics and surface morphology of the superhydrophobic/hydrophobic nanocomposite coatings prepared by an electrospinning method to coat various materials such as glass and metal. This is considered as a low cost method of fabrication for polymer solutions of Polystyrene (PS), Polymethylmethacrylate (PMMA) and Silicone Rubber (RTV). Si were prepared in various wt% of composition for each solutions. Contact angle measurement, surface tension, viscosity, roughness tests were calculated for all specimens. SEM showed the morphology of the surfaces after coated. PS and PMMA showed superhydrophobic properties for metal substrate, while Si showed hydroph

... Show More
View Publication Preview PDF
Scopus (27)
Crossref (12)
Scopus Clarivate Crossref
Publication Date
Wed Jun 01 2016
Journal Name
Journal Of Engineering
Experimental and Simulation for the Effect of Partial Shading on Solar Panel Performance
...Show More Authors

Partial shading is one of the problems that affects the power production and the efficiency of photovoltaic module. A series of experimental work have been done of partial shading of   monocrystalline PV module; 50W, Isc: 3.1A, Voc: 22V with 36 cells in series is achieved. Non-linear power output responses of the module are observed by applying various cases of partial shading (vertical and horizontal shading of solar cells in the module). Shading a single cell (corner cell) has the greatest impact on output energy. Horizontal shading or vertical shading reduced the power from 41W to 18W at constant solar radiation 1000W/m2 and steady state condition. Vertical blocking a column

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 03 2023
Journal Name
2023 Ieee International Conference On Energy Technologies For Future Grids (etfg)
Optimal Hybrid Type-2 Fuzzy-PID Controller for Blade Pitch Angle in Horizontal-axis Wind Turbines
...Show More Authors

In the modern world, wind turbine (WT) has become the largest source of renewable energy. The horizontal-axis wind turbine (HAWT) has higher efficiency than the vertical-axis wind turbine (VAWT). The blade pitch angle (BPA) of WT is controlled to increase output power generation over the rated wind speed. This paper proposes an accurate controller for BPA in a 500-kw HAWT. Three types of controllers have been applied and compared to find the best controller: PID controller (PIDC), fuzzy logic type-2 controller (T2FLC), and hybrid type-2 fuzzy-PID controller (T2FPIDC). This paper has been used Mamdani and Sugeno fuzzy inference systems (FIS) to find the best inference system for WT controllers. Furthermore, genetic algorithm (GA) and particl

... Show More
View Publication
Scopus (3)
Crossref (2)
Scopus Crossref
Publication Date
Thu Jun 10 2010
Journal Name
Iraqi Journal Of Laser
Experimental Investigation of a Laser Wireless Video Communication System Using Intensity Modulated /Direct Detection Technique
...Show More Authors

In this work Laser wireless video communication system using intensity modualtion direct
detection IM/DD over a 1 km range between transmitter and receiver is experimentally investigated and
demonstrated. Beam expander and beam collimeter were implemented to collimete laser beam at the
transmitter and focus this beam at the receiver respectively. The results show that IM/DD communication
sysatem using laser diode is quite attractive for transmitting video signal. In this work signal to noise
ratio (S/N) higher than 20 dB is achieved in this work.

View Publication Preview PDF