This paper has investigated experimentally the dynamic buckling behavior of AISI 303 stainless steel Aluminized and as received long columns. These columns, hot-dip aluminized and as received, are tested under dynamic buckling, 22 specimens, without aluminizing (type 1), and 50 specimens, with hot-dip aluminizing at different aluminizing conditions of dipping temperature and dipping time (type 2), are tested under dynamic compression loading and under dynamic combined loading (compression and bending) by using a rotating buckling test machine. The experimental results are compared with Perry Robertson interaction formula that used for long columns. Greenhill formula is used to get a mathematical model that descripts the buckling behavior of the specimens of type (1) under dynamic compression loading. The experimental results obtained show an advantageous influence of hot-dip aluminizing treatment on dynamic buckling behavior of AISI 303 stainless steel long columns. The improvement based on the average value of critical buckling stress, are as follow: (64.8 %) for long columns type (2), compared with columns type (1), under dynamic compression loading, and (56.6 %) for long columns type (2), compared with columns type (1), under dynamic combined loading, and (33.3 %) for long columns type (2) compared with Perry Robertson critical buckling stress.
ABSTRACT Background: resin cement type and intraoral temperature fluctuations may affect the fracture performance of successful zirconia restorations. To fill this gap, the purpose of this study is to evaluate and compare the influence of thermocycling on fracture resistance and mode of failure of monolithic zirconia crowns luted with Rely X™ U200 and BreezeTMself-adhesive resin cements as well as imply the effect of adding 2 % of polylysine (PLS) to these cements. Materials: 64 maxillary premolars were milled out of zirconia blocks using CAD/CAM milling system. They were divided into four groups (n = 16) according to the cement type. Four different resin cements were used (RelyXTMU200, Breeze™, RelyX™ U200 with 2 % PLS
... Show MoreBackground: Nanotechnology has emerged as a pivotal domain in material science research with extensive applications across various sectors including biotechnology and medicine. Nanoparticles offer unique properties facilitating advancements in nanobiotechnology, particularly in nanomedicine, to combat bacterial infections and antibiotic resistance. This study aimed to determine the application of nanoparticles, specifically nano-TiO2, in treating plasmid-mediated antibiotic resistance in both Gram-negative and Gram-positive bacteria. Method: We evaluated antibiotic and nanomaterial sensitivity through disc diffusion and broth microdilution assays. Plasmid curing experiments were conducted using varying concentrations of nano-TiO2 an
... Show MoreThe corrosion protection of low carbon steel in 2.5 M HCl solution by kiwi juice was studied at different temperatures and immersion times by weight loss technique. To study the determination of the optimum conditions from statistical design in evaluation of a corrosion inhibitor, three variables, were considered as the most dominant variables. These variables are: temperature, inhibitor concentration (extracted kiwi juice) and immersion time at static conditions.
These three variables are manipulated through the experimental work using central composite rotatable Box – Wilson Experimental Design (BWED) where second order polynomial model was proposed to correlate the studied variables with the corrosion rate o
... Show MoreThe research aims at introducing the principles of six sigma and if it had any effect of the dimensions of six sigma to improve the performance of the dentists and the availability of an appropriate environment in the center Specialist respondent to the application of six sigma principles and how to adopt Specialized Center under the dimensions of the six sigma and if there informed enough with the management methodology six sigma, and if you can adopt six sigma as one of the entrances to reduce medical errors. So Search creating six sigma five dimensions and are (the commitment and support of senior management, the focus on the patient, continuous improvement, training and civil, and infrastructure) as a variable int
... Show MoreAbstract
This study aims to find the relationships between social capital (social network, social trust, shared goals) and knowledge sharing (knowledge Donating, knowledge collecting) as independent variables and their impact on improving the quality of educational services (academic staffs quality, Quality of teaching methods and study curriculums). This research is an important, because it attempts to identify the relationship between social capital and the knowledge sharing and their effect on improving the quality of educational service for universities. The study problem was determined in several questions related to the nature of the correlation relationship - the impact between the different independent variables (
... Show MoreBraces in straight bridge systems improve the lateral-torsional buckling resistance of the girders by reducing the unbraced length, while in horizontally curved and skew bridges, the braces are primary structural elements for controlling deformations by engaging adjacent girders to act as a system to resist the potentially large forces and torques caused by the curved or skewed geometry of the bridge. The cross-frames are usually designed as torsional braces, which increase the overall strength and stiffness of the individual girders by creating a girder system that translates and rotates as a unit along the bracing lines. However, when they transmit the truck’s live load forces, they can produce fatigue cracks at their connection
... Show MoreThin films of Magnetite have been deposited on Galvanized Steel (G-S) alloy using RF-reactive magnetron sputtering technique and protection efficiency of the corrosion of G-S. A Three-Electrodes Cell was used in saline water (3.5 % NaCl) solution at different temperatures (298, 308, 318 & 328K) using potentiostatic techniques with. Electrochemical Impedance Spectroscopy (EIS) and fitting impedance data via Frequency Response Analysis (FRA) were applied to G-S alloy with Fe3O4 and tested in 3.5 % NaCl solution at 298K.Results taken from Nyquist and Bode plots were analyzed using software provided with the instrument. The results obtained show that the rate of corrosion of G.S alloy increased with increasing the temperatures from 298 t
... Show More