Preferred Language
Articles
/
alkej-212
Energy Saving of Heat Gain by Using Buried Pipe Inside a Roof
...Show More Authors

Abstract

    This work deals with a numerical investigation to evaluate the utilization of a water pipe buried inside a roof to reduce the heat gain and minimize the transmission of heat energy inside the conditioning space in summer season.     The numerical results of this paper showed that the reduction in heat gain and energy saving could be occurred with specific values of parameters, like the number of pipes per square meter, the ratio of pipe diameter to the roof thickness, and the pipe inlet water temperature. Comparing with a normal roof (without pipes), the results indicated a significant reduction in energy heat gain which is about 37.8% when the number of pipes per meter of roof length is 3.0 , the ratio of pipe diameter to the wall thickness (D/W) is 0.20, and the water inlet temperature is 30°C, while the minimum ratio of reduction 24% is achieved when the number of pipes per meter, the ratio of pipe diameter to the wall thickness, and the water inlet temperature are 27, 30 and 33 °C, respectively. The results also showed that there is a very small effect of pipe centre position inside the wall on the final heat transmission.

Keyword: Water pipe, Roof heat gain, Solar-air temperature.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Jul 27 2021
Journal Name
Journal Of Craniofacial Surgery
Morphometric Analysis of the Mental Foramen Variation in an Iraqi Population by Using Cone-Beam Computed Tomography
...Show More Authors

View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sun Apr 06 2014
Journal Name
Journal Of Economics And Administrative Sciences
Modeling Absolute Deviations Method by using Numerical Methods to measure the dispersion of the proposal for error
...Show More Authors

Is in this research review of the way minimum absolute deviations values ​​based on linear programming method to estimate the parameters of simple linear regression model and give an overview of this model. We were modeling method deviations of the absolute values ​​proposed using a scale of dispersion and composition of a simple linear regression model based on the proposed measure. Object of the work is to find the capabilities of not affected by abnormal values by using numerical method and at the lowest possible recurrence.

 

View Publication Preview PDF
Crossref
Publication Date
Thu Mar 30 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Genetic Variations of Echinococcus granulosus Isolated from Sheep and Cows by Using Fingerprint DNA Method in Iraq
...Show More Authors

The fingerprinting DNA method which depends on the unique pattern in this study was employed to detect the hydatid cyst of Echinococcus granulosus and to determine the genetic variation among their strains in different intermediate hosts (cows and sheep).  The unique pattern represents the number of amplified bands and their molecular weights with specialized sequences to one sample which different from the other samples.   Five hydatitd cysts samples  from cows and sheep were  collected, genetic analysis for  isolated DNA was done using PCR technique and  Random Amplified Polymorphic DNA reaction(RAPD) depending on (4) random primers, and the results showed:      

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Journal Of Engineering
Improving the Direction of Arrival Estimation Using the Parasitic Subspace Generated by Active-Parasitic Antenna (APA) Arrays
...Show More Authors

The improvement in Direction of Arrival (DOA) estimation when the received signals impinge on Active-Parasitic Antenna (APA) arrays will be studied in this work. An APA array consists of several active antennas; others are parasitic antennas. The responses to the received signals are measured at the loaded terminals of the active element. The terminals of the parasitic element are shorted. The effect of the received signals on the parasites, i.e., the induced short-circuit current, is mutually coupled to the active elements. Eigen decomposition of the covariance matrix of the measurements of the APA array generates a third subspace in addition to the traditional signal and noise subspaces generated by the all-active ante

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Apr 01 2023
Journal Name
Alexandria Engineering Journal
Employing Sisko non-Newtonian model to investigate the thermal behavior of blood flow in a stenosis artery: Effects of heat flux, different severities of stenosis, and different radii of the artery
...Show More Authors

View Publication
Scopus (31)
Crossref (32)
Scopus Clarivate Crossref
Publication Date
Sat Jul 01 2023
Journal Name
Journal Of Engineering
Performance of Solar Adsorption Cooling System Using Methanol and Activated Carbon as a Working Pair
...Show More Authors

The need for renewable energy sources is higher than ever due to rising global warming, climate change, and ozone depletion. For refrigeration and air conditioning applications, adsorption refrigeration systems are viable alternatives cooling techniques. This study is a topic and part of the M.Sc. thesis. A field solar-powered ice maker unit was created, studied, tested, and evaluated on the 13th and 30th of May, 2022. Activated carbon and methanol pair was used to set up a refrigeration system in Baghdad (Al Dora). Experimental tests were carried out outdoors to determine the coefficient of performance COP and specific cooling power SCP of the system. The results showed that the lowest temperature

... Show More
View Publication Preview PDF
Crossref (7)
Crossref
Publication Date
Mon Jun 19 2023
Journal Name
Journal Of Engineering
Compound Heat Transfer Enhancement in Dimpled and Sinusoidal Metal Solar Wall Ducts Fitted with Wired Inserts
...Show More Authors

An improved Metal Solar Wall (MSW) with integrated thermal energy storage is presented in this research. The proposed MSW makes use of two, combined, enhanced heat transfer methods. One of the methods is characterized by filling the tested ducts with a commercially available copper Wired Inserts (WI), while the other one uses dimpled or sinusoidal shaped duct walls instead of plane walls. Ducts having square or semi-circular cross sectional areas are tested in this work.
A developed numerical model for simulating the transported thermal energy in MSW is solved by finite difference method. The model is described by system of three governing energy equations. An experimental test rig has been built and six new duct configurations have b

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Jun 15 2022
Journal Name
Malaysian Journal Of Science
STUDY THE RELATIONSHIP BETWEEN BREMSSTRAHLUNG DOSE RATE AND THE ENERGY OF BETA RAY FOR DIFFERENT TYPES OF SHIELD
...Show More Authors

The dose rate for bremsstrahlung radiation from beta particles with energy (1.710) MeV and (2.28) MeV which comes from (32P and 90Y) beta source respectively have been calculated through six materials (polyethylene, wood, aluminum, iron, tungsten and lead) for first shielding material with thickness (x=1) mm which are putting between beta sources and second shield (polyethylene, aluminum and lead) with thickness (1, 2 &4) mm have been calculated. The distance between beta source and second shield is constant (D=1) cm. This dose rate was found by program called Rad Pro Calculator (version 3.26). The results of dose rate of beta particles were plotted as a function to the atomic number (Z) for first shield materials for each

... Show More
Preview PDF
Publication Date
Wed May 29 2019
Journal Name
Indian Journal Of Physics
Effect of lasing energy on the structure and optical and gas sensing properties of chromium oxide thin films
...Show More Authors

View Publication
Scopus (4)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Thu Sep 14 2023
Journal Name
Al-khwarizmi Engineering Journal
Applying Scikit-learn of Machine Learning to Predict Consumed Energy in Al-Khwarizmi College of Engineering, Baghdad, Iraq
...Show More Authors

Globally, buildings use about 40% of energy. Many elements, such as the physical properties of the structure, the efficiency of the cooling and heating systems, the activity of the occupants, and the building’s sustainability, affect the energy consumption of a building. It is really difficult to predict how much energy a building will need. To improve the building’s sustainability and create sustainable energy sources to reduce carbon dioxide emissions from fossil fuel combustion, estimating the building's energy use is necessary. This paper explains the energy consumed in the lecture building of the Al-Khwarizmi College of Engineering, University of Baghdad (UOB), Baghdad, Iraq. The weather data and the building construction informati