Preferred Language
Articles
/
alkej-209
Thermal Field Analysis of Oblique Machining Process with Infrared Image for AA6063-T6
...Show More Authors

Abstract

 Metal cutting processes still represent the largest class of manufacturing operations. Turning is the most commonly employed material removal process. This research focuses on analysis of the thermal field of the oblique machining process. Finite element method (FEM) software DEFORM 3D V10.2 was used together with experimental work carried out using infrared image equipment, which include both hardware and software simulations. The thermal experiments are conducted with AA6063-T6, using different tool obliquity, cutting speeds and feed rates. The results show that the temperature relatively decreased when tool obliquity increases at different cutting speeds and feed rates, also it is found that the mean tool rake face temperature distribution decreases with increase of tool obliquity. The result also show that the maximum error between the predicted and measured temperatures by IR camera was between 6-27 °C.

Keywords: Infrared, Deform-3D, tool obliquity, turning.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Aug 22 2019
Journal Name
Separation Science And Technology
Modification of Langmuir model for simulating initial pH and temperature effects on sorption process
...Show More Authors

Scopus (43)
Crossref (30)
Scopus Clarivate Crossref
Publication Date
Thu Apr 01 2021
Journal Name
Basra Journal Of Science
Organic Field Effect Transistor Based on P3HT with Two Different Gate Dielectrics
...Show More Authors

The electrical performance of bottom-gate/top source-drain contact for p-channel organic field-effect transistors (OFETs) using poly(3-hexylthiophene) (P3HT) as an active semiconductor layer with two different gate dielectric materials, Polyvinylpyrrolidone (PVP) and Hafnium oxide (HfO2), is investigated in this work. The output and transfer characteristics were studied for HfO2, PVP and HfO2/PVP as organic gate insulator layer. Both characteristics show a high drain current at the gate dielectric HfO2/PVP equal to -0.0031A and -0.0015A for output and transfer characteristics respectively, this can be attributed to the increasing of the dielectric capacitance. Transcondactance characteristics also studied for the three organic mater

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Sep 01 2017
Journal Name
International Research Journal Of Engineering And Technology
A POWERFUL AUTOMATED IMAGE INDEXING AND RETRIEVAL TOOL FOR SOCIAL MEDIA Sample
...Show More Authors

The Internet image retrieval is an interesting task that needs efforts from image processing and relationship structure analysis. In this paper, has been proposed compressed method when you need to send more than a photo via the internet based on image retrieval. First, face detection is implemented based on local binary patterns. The background is notice based on matching global self-similarities and compared it with the rest of the image backgrounds. The propose algorithm are link the gap between the present image indexing technology, developed in the pixel domain, and the fact that an increasing number of images stored on the computer are previously compressed by JPEG at the source. The similar images are found and send a few images inst

... Show More
Preview PDF
Publication Date
Mon Aug 01 2022
Journal Name
Indonesian Journal Of Electrical Engineering And Computer Science
Variable length error correcting code for image in OFDM and PAPR reduction
...Show More Authors

Data <span>transmission in orthogonal frequency division multiplexing (OFDM) system needs source and channel coding, the transmitted data suffers from the bad effect of large peak to average power ratio (PAPR). Source code and channel codes can be joined using different joined codes. Variable length error correcting code (VLEC) is one of these joined codes. VLEC is used in mat lab simulation for image transmission in OFDM system, different VLEC code length is used and compared to find that the PAPR decreased with increasing the code length. Several techniques are used and compared for PAPR reduction. The PAPR of OFDM signal is measured for image coding with VLEC and compared with image coded by Huffman source coding and Bose-

... Show More
View Publication
Scopus Crossref
Publication Date
Sat Jul 01 2023
Journal Name
International Journal Of Intelligent Engineering And Systems
An Efficient Cryptosystem for Image Using 1D and 2D Logistic Chaotic Maps
...Show More Authors

View Publication Preview PDF
Scopus (4)
Crossref (2)
Scopus Crossref
Publication Date
Sun Jun 06 2010
Journal Name
Baghdad Science Journal
The contrast and illumination technique for image capturing under different Tungsten illumination
...Show More Authors

The digital camera which contain light unit inside it is useful with low illumination but not for high. For different intensity; the quality of the image will not stay good but it will have dark or low intensity so we can not change the contrast and the intensity in order to increase the losses information in the bright and the dark regions. . In this search we study the regular illumination on the images using the tungsten light by changing the intensities. The result appears that the tungsten light gives nearly far intensity for the three color bands(RGB) and the illuminated band(L).the result depend on the statistical properties which represented by the voltage ,power and intensities and the effect of this parameter on the digital

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Nov 21 2022
Journal Name
Sensors
Deep Learning-Based Computer-Aided Diagnosis (CAD): Applications for Medical Image Datasets
...Show More Authors

Computer-aided diagnosis (CAD) has proved to be an effective and accurate method for diagnostic prediction over the years. This article focuses on the development of an automated CAD system with the intent to perform diagnosis as accurately as possible. Deep learning methods have been able to produce impressive results on medical image datasets. This study employs deep learning methods in conjunction with meta-heuristic algorithms and supervised machine-learning algorithms to perform an accurate diagnosis. Pre-trained convolutional neural networks (CNNs) or auto-encoder are used for feature extraction, whereas feature selection is performed using an ant colony optimization (ACO) algorithm. Ant colony optimization helps to search for the bes

... Show More
View Publication
Scopus (30)
Crossref (25)
Scopus Clarivate Crossref
Publication Date
Sun Sep 01 2024
Journal Name
Inorganic Chemistry Communications
Investigation of optical, mechanical, thermal, wettability, and antibacterial activity of polyvinyl alcohol mixed with clay nanoparticles
...Show More Authors

View Publication
Scopus (8)
Crossref (10)
Scopus Clarivate Crossref
Publication Date
Wed Aug 17 2022
Journal Name
Sustainability
Experimental Evaluation of the Thermoelectrical Performance of Photovoltaic-Thermal Systems with a Water-Cooled Heat Sink
...Show More Authors

A design for a photovoltaic-thermal (PVT) assembly with a water-cooled heat sink was planned, constructed, and experimentally evaluated in the climatic conditions of the southern region of Iraq during the summertime. The water-cooled heat sink was applied to thermally manage the PV cells, in order to boost the electrical output of the PVT system. A set of temperature sensors was installed to monitor the water intake, exit, and cell temperatures. The climatic parameters including the wind velocity, atmospheric pressure, and solar irradiation were also monitored on a daily basis. The effects of solar irradiation on the average PV temperature, electrical power, and overall electrical-thermal efficiency were investigated. The findings i

... Show More
View Publication
Scopus (29)
Crossref (26)
Scopus Clarivate Crossref
Publication Date
Sat Jun 03 2017
Journal Name
Journal Of Diagnostic Medical Sonography
The Diagnostic Accuracy of Sonography, With Graded Compression to Image Acute Appendicitis Compared to Histopathologic Results
...Show More Authors

Acute appendicitis is the most common surgical abdominal emergency. Its clinical diagnosis remains a challenge to surgeons, so different imaging options were introduced to improve diagnostic accuracy. Among these imaging modality choices, diagnostic medical sonography (DMS) is a simple, easily available, and cost effective clinical tool. The purpose of this study was to assess the accuracy of DMS, in the diagnosis of acute appendicitis compared to the histopathology report, as a gold standard. Between May 2015 and May 2016, 215 patients with suspected appendicitis were examined with DMS. The DMS findings were recorded as positive and negative for acute appendicitis and compared with the histopathological results, as a gold standard

... Show More
View Publication
Scopus (2)
Crossref (2)
Scopus Crossref