The performance of a solar cell under sun radiation is necessary to describe the electrical parameters of the cell. The Prova 200 solar panel analyzer is used for the professional testing of four solar cells at Baghdad climate conditions. Voltage -current characteristics of different area solar cells operated under solar irradiation for testing their quality and determining the optimal operational parameters for maximum electrical output were obtained. A correlation is developed between solar cell efficiency h and the corresponding solar cell parameters; solar irradiance G, maximum power Pmax, and production date P. The average absolute error of the proposed correlation is 5.5% for 40 data points. The results also show that the new solar panels have the highest efficiency compared with the older ones.
Objective :To evaluate elderly's environmental practices concerning fall prevention at governmental elderly care homes in Baghdad city. Methodology: A quazi- Experimental study was carried out in governmental elderly care homes at Baghdad city, during the period 1st, June 2014 to 30th November, 2014 , selected a purposive " Non – probability " sample of (40) elderly men and women aged (60) years old and over who were resident in governmental elderly care homes " Al Ceelakh and Al Sader elderly care homes", the data was collected through the use of constructed questionnaire that consist of (23) items,
Abstract
The study aimed: To assess the level of trainers' knowledge about the application of strategies and to find out the relationship between Trainer's knowledge and their socio-demographic characteristics.
Methodology: Using the pre-experimental design of the current study, for one group of 47 trainers working at the private Autism Centers in Baghdad, data was collected from 8/January / 2022 to 13 /February /2022. Using non-probability samples (convenient samples), self-management technology in which trainers fill out the questionnaire form themselves was used in the data collection process; it was analyzed through descriptive and inference statistics.
Objectives: To assess pregnant women’s knowledge regarding syphilisand to find out the relationship between women’s knowledge regarding syphilis infection and demographic and reproductive variables. Methodology: A descriptive analytical study of non probable (purposive sample) of 250 pregnant women during their different gestational ages for the period (October 2nd to April 25th 2013) by using questionnaire format consists of demographic variables and items of women's knowledge regarding syphilis who are visiting primary health care centers in Al-Kharkh and Al-Rrusafa in Baghdad city. The coefficient relia
The current, research, aims, to, verify, the relationship between talent development practices and organizational performance through a mediating role of creative organizational climate at the Institution of Industrial Development and Research- the Iraqi Industry Ministry. The descriptive and analytic approach was adopted as a research design. The research sample was represented by a number of managers and employees who work at the middle management level. The researchers used the questionnaire as the main method for collecting data to achieve the main research objective. It was distributed 162 questionnaires, of which 146 received; and then all of those were used on the final statistical analysis. The sample response-rate rate w
... Show MorePressure ulcers are one of the most common hospital-acquired major conditions that occur in patients with mobility limitations and result in endangering patient safety, prolonging hospital stay, disability, and death. This study aims to examine the level of nurses’ practices and perceived barriers for preventing pressure ulcers among critically ill patients.
A cross-sectional survey was conducte
Heat transfer process and fluid flow in a solar chimney used for natural ventilation are investigated numerically in the present work. Solar chimney was tested by selecting different positions of absorber namely: at the back side, front side, and at the middle of the air gap. CFD analysis based on finite volume method is used to predict the thermal performance, and air flow in two dimensional solar chimney under unsteady state condition, to identify the effect of different parameters such as solar radiation. Results show that a solar chimney with absorber at the middle of the air gap gives better ventilation performance. A comparison between the numerical and previous experimental results shows fair agreement.
Different frequency distributions models were fitted to the monthly data of raw water Turbidity at water treatment plants (WTPs) along Tigris River in Baghdad. Eight water treatment plants in Baghdad were selected, with raw water turbidity data for the period (2008-2014). The frequency distribution models used in this study are the Normal, Log-normal, Weibull, Exponential and two parameters Gamma type. The Kolmogorov-Smirnov test was used to evaluate the goodness of fit. The data for years (2008-2011) were used for building the models. The best fitted distributions were Log-Normal (LN) for Al-Karkh, Al-Wathbah, Al-Qadisiya, Al- Dawrah and, Al-Rashid WTPs. Gamma distribution fitted well for East Tigris and Al-Karamah WTPs. As for Al-
... Show MoreDifferent frequency distributions models were fitted to the monthly data of raw water Turbidity at water treatment plants (WTPs) along Tigris River in Baghdad. Eight water treatment plants in Baghdad were selected, with raw water turbidity data for the period (2008-2014). The frequency distribution models used in this study are the Normal, Log-normal, Weibull, Exponential and two parameters Gamma type. The Kolmogorov-Smirnov test was used to evaluate the goodness of fit. The data for years (2008-2011) were used for building the models. The best fitted distributions were Log-Normal (LN) for Al-Karkh, Al-Wathbah, Al-Qadisiya, Al-Dawrah and, Al-Rashid WTPs. Gamma distribution fitted well for East Tigris and Al-Karamah
... Show MoreThe thermal and electrical performance of different designs of air based hybrid photovoltaic/thermal collectors is investigated experimentally and theoretically. The circulating air is used to cool PV panels and to collect the absorbed energy to improve their performance. Four different collectors have been designed, manufactured and instrumented namely; double PV panels without cooling (model I), single duct double pass collector (model II), double duct single pass (model III), and single duct single pass (model IV) . Each collector consists of: channel duct, glass cover, axial fan to circulate air and two PV panel in parallel connection. The temperature of the upper and lower surfaces of PV panels, air temper
... Show More