This research studying the phenomenon of Doppler (frequency Doppler) as a method through which the direction and speed of the blood cells flows in blood vessels wear measured. This Doppler frequency is relied upon in medicine for measuring the speed of blood flow, because the blood flow is an important concept from the concepts of medicine. It represents the function and efficient of the heart and blood vessels in the body so any defect in this function will appear as a change in the speed of blood flow from the normal value assumed. As this speed changes alot in cases of disease and morbidity of the heart, so in order to identify the effect of changing the Doppler frequency on the speed of blood flow and the relationship of this frequency with the angles of transitions and receptions and the effect of changing the ultrasound transmitted frequencies on the measured velocities .The Doppler ultrasound system has been used which is more efficient and easier to be widely used as a practical application in Al Yarmouk Teaching Hospital on two subjects. The normal had a natural medical history in the blood vessels, and abnormal had carotid artery stenosis. This device will give the flow velocity of blood in the blood vessels which is useful to the examiner, the equation of Doppler as a mathematical model in the research is adopted the measured speed to clarify the amount of change in the frequency (shift in frequency). This speed was measured in five different blood vessels, large arteries (abdominal aorta and carotid artery in the neck) and large veins (the inferior vena cava across the abdomen and the external Jugular vein in the neck) and capillaries in the hand and fingers. Then using the measured velocities in these vessels the Doppler frequency was calculated from this mathematical model using MATLAB program, was found that as velocity of the blood increases, so does the Doppler frequency and vice versa. The greater the value of the Doppler angle used in the device then the Doppler frequency decreased and vice versa. As well as increasing the transmitted frequency giving an increase in the speed of blood flow and in the Doppler frequency and vice versa. It was observed during the practical work that it was possible to get the speed of blood flow in different blood vessels, arteries and veins easily, but to less extent in the capillary vessels since in fact the value of the received frequency was very small.
The research aims to formulate a model for research on the dimensions of the Leader-member exchange theory according to the ideas and thoughts of Liden /Maslyn, Hammer and impact on job satisfaction and measure these dimensions at asiacell communications to identify the extent of convergence between theoretical dimensions share leader – member Exchange (LMX) with leadership style used in this company, we have been building scale contains two variables, independent variable Leader-member exchange theory five dimensions (effect , Loyalty, contribution, respect professional, and support) the certified job satisfaction variable dimensions (job security, The Style of management, organizational climate, appreciation, and work itself)
... Show MoreBackground: Soft Laser has been advantageous in medical applications and is widely used in clinical practice. It is applied because it doesn’t cause the significant thermal effects or tissue hurt when irradiated. The blood response to low power laser radiation provides information about processes of laser radiation interaction with live creatures. Objective: The aim of the current work was to evaluate the laser-induced changes of in vitro erythrocyte sedimentation rate (ESR), mean corpuscular volume (MCV), and mean corpuscular hemoglobin concentration (MCHC) in patients with breast cancer by irradiating a human blood sample using a green laser and comparing its effects before and after irradiation with the same power density (100mW/c
... Show MoreThe influence of sensing element length of no-core fiber strain sensor has been studied and experimentally demonstrated, four different lengths of 125 μm diameter no-core fiber is fused between two standard single-mode fibers and bi-directionally strained, the highest obtained sensitivity was around 16.37 pm με -1 which was exhibited in the shortest no-core fiber segment, to the best of our knowledge this is the first study of the influence of no-core fiber strain sensors length on sensor sensitivity. The proposed sensor can be used in many opto-mechanical applications such as, structural health monitoring, aerospace vehicles and airplane components monitoring.
Objectives: To assess the relation between breast cancer & blood groups, identify the importance of women
age group and the relation of age with breast cancer.
Methodology: The study was performed on (115) women who were diagnosed with breast cancer in different
stages of disease and different ages. Blood samples were taken from them to demonstrate their blood groups and
(20) fresh tumor tissue samples were obtained; the tumor tissue used as a source of lectin for hemagglutinate
with erythrocyte of different blood groups. The study conducted at Baghdad Teaching Hospital and Radiation &
Nuclear Medicine Hospital from January, 2007 through June 2007.
Results: The study shows that the highest percentage of women
Background: Leukemia is a cancer of blood cells which treated by different anticancer agents, Plants nowadays considered a new source for the development of new anticancer agent. Euphorbia Lathyris use in folklore to treat skin cancer. Objective Euphorbia lathyris seeds phytochemically investigated then examined its cytotoxic activity against leukemia cells. Materials and Methods: Euphorbia lathyris seed was extracted by maceration with different organic solvents (petroleum ether, chloroform and methanol), each organic extract submitted to phytochemical investigation and evaluated its cytotoxic activity on Leukemic blood with three different doses (50,100 and 150 µg mL¯1) and three different intervals. The data were evaluated by two-way a
... Show MoreNon-thermal argon plasma needle at atmospheric pressure was
constructed. The experimental setup was based on a simple and low
cost electric component that generates a sufficiently high electric
field at the electrodes to ionize the argon gas which flow at
atmospheric pressure. A high AC power supply was used with 1.1
kV and 19.57 kHz. Non-thermal Argon plasma used on blood
samples to show the ability of non-thermal plasma to promote blood
coagulation. Three tests have been done to show the ability of plasma
to coagulate both normal and anti-coagulant blood. Each blood
sample has been treated for varying time from 20sec. to 180sec. at
different distances. The results of the current study showed that the
co
The fluctuations in oil prices in world markets affect the general budget and the trade balance of the rent countries, because oil is a strategic commodity affected by economic and political factors. The fluctuations in oil prices affect the public budgets of the rent countries through the public revenue side of oil revenues. On the other hand, these fluctuations affect the balance of trade through the volume of oil exports, which lead to imbalance of trade surplus or deficit . &nbs
... Show MoreThe European Unit has never been affected by a serious phenomena as the phenomena of the advancing of the far right parties. Though these parties vary in their impact in their original countries, they agree on one important issue which is the deconstruction of the European unit and limiting its supernational powers. These increasing popular parties aim at more national independence in decision making away from the decisions taken by Brussels. Moreover, they criticize the financial and administrative corruption accompanied many of the rescuing procedures directed for example towards countries like Greece and Spain during the international economic crisis. This failure nourishes many of the negative feelings against the European unit which
... Show More