Abstract: Microfluidic devices present unique advantages for the development of efficient drug assay and screening. The microfluidic platforms might offer a more rapid and cost-effective alternative. Fluids are confined in devices that have a significant dimension on the micrometer scale. Due to this extreme confinement, the volumes used for drug assays are tiny (milliliters to femtoliters).
In this research, a microfluidic chip consists of micro-channels carved on substrate materials built by using Acrylic (Polymethyl Methacrylate, PMMA) chip was designed using a Carbon Dioxide (CO2) laser machine. The CO2 parameters have influence on the width, depth, roughness of the chip. In order to have regular
... Show MoreA mathematical model constructed to study the combined effects of the concentration and the thermodiffusion on the nanoparticles of a Jeffrey fluid with a magnetic field effect the process of containing waves in a three-dimensional rectangular porous medium canal. Using the HPM to solve the nonlinear and coupled partial differential equations. Numerical results were obtained for temperature distribution, nanoparticles concentration, velocity, pressure rise, pressure gradient, friction force and stream function. Through the graphs, it was found that the velocity of fluid rises with the increase of a mean rate of volume flow and a magnetic parameter, while the velocity goes down with the increasing a Darcy number and lateral walls. Also, t
... Show MoreForeign body embolization is a rare but serious iatrogenic complication that might necessitate transcatheter or even surgical retrieval. A broken double-lumen catheter was snared using a goose neck snare kit. The procedure was successful, and the patient experienced no further complications.
Background: The type of dental implant surface is one of many factors that determine the success of implant restoration. This study aimed to study the effect of mixture of nano titanium oxide with nanohydroxyapatite coating of screw shaped CPTi dental implant on bond strength at bone implant interface by torque removal test related to two healing periods (2 and 6 weeks). Materials and methods: Dip coating process was performed to get an even coating layer on CPTi screws. X-ray diffraction (XRD) analysis and microscopical examination were performed on the coating surfaces of the CPTi. The tibia of 10 white New Zealand rabbits was chosen as implantation sites. The tibia of each rabbit received two screws, one was coated with mixture of nanoT
... Show MoreThis paper studies the oscillation properties and asymptotic behavior of all solutions of the 2×2 system of second-order half-linear neutral differential equations. Four results are obtained in this research. The first and second results are auxiliary results while the third and fourth results are main results. All possible cases of non-oscillating bounded solutions for this system are estimated and analyzed. It is noted that the parameters that affect the volatility of the solutions are Qi,Ri on the one hand and r1 and r2 on the other hand. For this purpose, and through investigation, it is shown that there are only fourteen possible cases of non-oscillating bounded solutions for this system, so all these cases must be treated, in the fir
... Show MoreObjective: to evaluate the increase in weight after biological agents and the association of weight gain with the body mass index among a sample of patients attending Baghdad Teaching Hospital Methods: A prospective study is carried out in Baghdad teaching hospital biological units and outpatient clinic of rheumatology for a period of one year starting On April 2015 and ending on March 2016. 120 patients were included in the study 40 psoriatic arthritis .40 ankylosing spondylitis and 40 rheumatoid arthritis Results : The study findings indicate that significance differences are seen regarding weight gain and b
In this paper, we investigate the basic characteristics of "magnetron sputtering plasma" using the target V2O5. The "magnetron sputtering plasma" is produced using "radio frequency (RF)" power supply and Argon gas. The intensity of the light emission from atoms and radicals in the plasma measured by using "optical emission spectrophotometer", and the appeared peaks in all patterns match the standard lines from NIST database and employed are to estimate the plasma parameters, of computes electron temperature and the electrons density. The characteristics of V2O5 sputtering plasma at multiple discharge provisos are studied at the "radio frequency" (RF) power ranging from 75 - 150 Wat
... Show More