Joseph Curtis wrote in his book (Introduction to Semiotics narrative and rhetoric) on the development of a semiotic project in exploring the meaning of communion. The book is rich in theoretical and analytical benefits both in the approach of texts and in the pursuit of letters in search of mechanisms of scriptural and scriptural generation and mechanics in narrative production, especially as the book offers exercises that help to assess the distance separating the narrative spread from the sin of the text, for the semiotics, Refers to the theoretical developments of the science of relations, through the combination of conventional definitions and the representative and comparative limitations, to provide an approach to the application of the semiarithian story of the semantics of the general organization of the sequences .. We will try in this study to monitor the following:
The philosophical perspective of semiotic terms.
Procedural deliberation of conceptual perspectives.
Background: Adipose derived-mesenchymal stem cells have been used as an alternative to bone marrow cells in this study. Objective: We investigated the in vitro isolation, identification, and differentiation of stem cells into neuron cells, in order to produce neuron cells via cell culture, which would be useful in nerve injury treatment. Method: Mouse adipose mesenchymal stem cells were dissected from the abdominal subcutaneous region. Neural differentiation was induced using β-mercaptoethanol. This study included two different neural stage markers, i.e. nestin and neurofilament light-chain, to detect immature and mature neurons, respectively. Results: The immunocytochemistry results showed that the use of β-mercaptoethanol resulted in
... Show MoreAqueous extract of poppy plant) Papaver nudicaule) with five concentrations (50, 100, 150, 200 and 250) mg/l were used to anesthetize fingerlings of the common carp Cyprinus carpio (Mean total length 8.91 ± 0.31 cm and mean total weight 7.72 ± 1.19 gm) instead of the traditional use of MS-222. Results showed that extracted solution of poppy have partial and overall anesthesia effect on these fishes with inverse relationship between the concentrations used and the time needed to reach partial and overall anesthesia, and also direct relationship between concentrations used and time needed for fish recovery. Best results were obtained by using a concentration of 250 mg/l, where time for partial anesthesia was 8 ± 1.52 m
... Show Moreسرطان البنكرياس هو مرض ذو معدل وفيات مرتفع، ولا يزال التشخيص المبكر لسرطان البنكرياس يمثل تحديًا. يظل معدل البقاء النسبي لمدة 5 سنوات أقل من 8%، والاستراتيجيات العلاجية غير فعالة في زيادة معدلات بقاء المريض على قيد الحياة. في خلايا سرطان البنكرياس، ارتبطت مقاومة العلاج بالتغيرات الجينية التي تؤدي إلى ظهور مسارات خلوية شاذة؛ ولذلك، هناك ما يبرر ايجاد استراتيجيات جديدة لعلاج هذا المرض. هنا، سعينا لاستكشاف
... Show MoreOptical fiber technology is without a doubt one of the most significant phases of the communications revolution and is crucial to our daily lives. Using the free version (2022) of RP Fiber Calculator, the modal properties for optical fibers with core radii (1.5−7.5) μm, core index (1.44−1.48) and cladding index (1.43−1.47) have been determined at a wavelength of 1000 nm. When the fiber core’s radius is larger than its operating wavelength, multimode fibers can be created. The result is a single-mode fiber in all other cases. All of the calculated properties, it has been shown, increase with increasing core radius. The modes’ intensity profiles were displayed.
The interaction of interplanetary coronal mass ejections (ICME) with each other and with co-rotating interaction regions (CIR) changes their configuration, dynamics, magnetic field and plasma characteristics and can make space weather forecasting difficult. During the period of March 20–25, 2011, the Solar Terrestrial Relation Observatory (
Abstract: A novel design of Mach Zehnder Interferometer (MZI) in terms of using special type of optical fiber that has double clad with graded distribution of the refractive index that can be easily implemented practically was suggested and simulated in this work. The suggested design is compact, rapid, and is simple to be modified and tested. The simulated design contains a MZI of 1546.74 nm of central wavelength that is constructed using special type of double clad optical fiber that has two different numerical apertures. The first aperture will supply single mode propagation via its core, while the second numerical aperture supports a zigzag wave propagation (multimode) in the first clad region. The interferometer’s
... Show MoreThe main purpose of this paper is to introduce a some concepts in fibrewise totally topological space which are called fibrewise totally mapping, fiberwise totally closed mapping, fibrewise weakly totally closed mapping, fibrewise totlally perfect mapping fibrewise almost totally perfect mapping. Also the concepts as totally adherent point, filter, filter base, totally converges to a subset, totally directed toward a set, totally rigid, totally-H-set, totally Urysohn space, locally totally-QHC totally topological space are introduced and the main concept in this paper is fibrewise totally perfect mapping in totally top
Статья посвящена возможности использования в обучении русскому языку как иностранному лингвоориентированной методики для арабских студентов. Обосновывается термин «лингвоориентированная методика», предложенный В. Н. Вагнер, и на основе положений заявленной методики проводится сопоставление изучаемого (русского) языка с родным (арабским) языком обучающихся.
Photonic Crystal Fiber Interferometers (PCFIs) are widely used for sensing applications. This work presents the fabrication and the characterization of a relative humidity sensor based on a polymer-coated photonic crystal fiber that operates in a Mach- Zehnder Interferometer (MZI) transmission mode. The fabrication of the sensor involved splicing a short (1 cm) length of Photonic Crystal Fiber (PCF) between two single-mode fibers (SMF). It was then coated with a layer of agarose solution. Experimental results showed that a high humidity sensitivity of 29.37 pm/%RH was achieved within a measurement range of 27–95%RH. The sensor also showed good repeatability, small size, measurement accuracy and wide humidity range. The RH sensitivity o
... Show More