The study is based on the selective binding ability of the drug compound procaine (PRO) on a surface imprinted with nylon 6 (N6) polymer. Physical characterization of the polymer template was performed by X-ray diffraction and DSC thermal analysis. The imprinted polymer showed a high adsorption capacity to trap procaine (237 µg/g) and excellent recognition ability with an imprinted factor equal to 3.2. The method was applied to an extraction column simulating a solid-phase extraction to separate the drug compound in the presence of tinoxicam and nucleosimide separately and in a mixture of them with a recovery rate more than the presence of tinoxicam and nucleosimide separately and in a mixture of them with a recovery rate of more than 82%. Separation efficiency and excellent selectivity for procaine were ensured using a mixed solution injected into an HPLC technique consisting of a C18 column with a mobile phase mixture of water-acetonitrile (75:25) at pH 3.3. The study of drug control using an imprinted polymer with procaine compound showed that the complete drug release process is faster at pH1 in a maximum period of 80 min. The proposed method was successfully applied on some of the available pharmaceuticals, and it showed high selectivity for the separation of PRO, RE % was < 1.18, and RSD was less than 0.447.
Diarrhea is a real disease in childhood which could cause death. Therefore, this study was conducted to isolate Salmonella from 350 stool samples taken from children under five years in age, suffering from diarrhea during the period from March 2019 to March 2020 in Tikrit city / Iraq. The results showed the possibility to isolate ten isolates of Salmonella enterica subsp. Enterica, an infection rate, represents 2.875% of the total rate of patients who suffer from diarrhea. The virulence genes were investigated for ten isolates of S. enterica subsp. enterica, the result is that all isolates possessed the genes stn, invA, lpfA with an appearance percentage of 100%, whi
... Show MoreThis work was influenced the separation and preconcentration steps were carried out to determination of metformin (MET) in pharmaceutical preparations and human serum samples. Complex formation method and cloud-point extraction (CPE) coupling with UV-Visible spectrophotometry were used to investigated of study target.The results has showed the best optical characteristic for calibration curve and statistical data which were obtained under optimum conditions. The first method is based on the reaction of MET with nickel (II) in alkaline medium an absorption maximum ?)max) at 434nm. ''Beer's low'' is obeyed in the concentration range (10-100µg.ml-1) with molar absorptivity of 3.9x103 L.mol-1.cm-1.The limit of detection and quantitation valu
... Show MoreIn this paper, the proposed phase fitted and amplification fitted of the Runge-Kutta-Fehlberg method were derived on the basis of existing method of 4(5) order to solve ordinary differential equations with oscillatory solutions. The recent method has null phase-lag and zero dissipation properties. The phase-lag or dispersion error is the angle between the real solution and the approximate solution. While the dissipation is the distance of the numerical solution from the basic periodic solution. Many of problems are tested over a long interval, and the numerical results have shown that the present method is more precise than the 4(5) Runge-Kutta-Fehlberg method.
The pervaporation using a commercial hydrophilic ceramic membrane supplied from PERVATECH was conducted. The dehydration of ethanol/ water system was used as a model for the pervaporation study. Pervaporation experiments of ethanol/water system were carried out in the temperature range of 303-343K, ethanol concentration in the feed 10-90 vol. % and the feed flow rate in the range of 0.5-10 L/min. In this work, the effect of operation parameters on permeates fluxes as well as permeates separation factors have been studied. The Water flux is strongly dependent on the temperature; it increased with increasing in temperature, which in turn decreased the selectivity of membrane to water molecules.
In addition water flux was decr
... Show More