Preferred Language
Articles
/
aHgee58BuRolNscLE-PN
Performance Evaluation of TB-LAMP in the Diagnosis of Pulmonary Tuberculosis
...Show More Authors

Background: Tuberculosis (TB), caused by Mycobacterium tuberculosis (MTB), is one of the most common infectious diseases, especially in countries with limited healthcare resources. Early and accurate diagnosis is essential to curb its spread, and loop-mediated isothermal amplification (LAMP) is a rapid, cost-effective, and reliable molecular diagnostic method. Objective: The objective of this study was to evaluate the performance of TB-LAMP as a rapid and reliable diagnostic tool for pulmonary TB and compare it with direct smears and Gene Xpert, using culture as a reference. Materials: Between February and July 2025, a total of 397 patients (227 men and 170 women) were enrolled in the study. Samples were tested by smear microscopy, culture, Xpert MTB/RIF, and TB-LAMP. Results: Of the 397 patients, 84 (21.15%) were culture-positive. Among culture-positive patients, 81 (96.4%) were positive by Gene Xpert, 69 (82.1%) by TB-LAMP, and 49 (58.3%) by direct smear microscopy. Using culture as the reference standard, the specificity, positive predictive value (PPV), and negative predictive value (NPV) of the TB-LAMP assay were 82.1% (73.9%–90.3%), 99.0% (97.9%–100%), 95.8% (91.2%–100%), and 95.4% (93.1%–97.7%), respectively. Conclusions: The TB-LAMP assay exhibits high diagnostic accuracy for the detection of Mycobacterium tuberculosis , making it a rapid, cost-effective, and reliable alternative to conventional methods, especially in resource-poor settings.

Crossref
View Publication
Publication Date
Fri Jul 21 2023
Journal Name
Journal Of Engineering
Performance Evaluation and Comparison Between LDPC and Turbo Coded MC-CDMA
...Show More Authors

This work presents a comparison between the Convolutional Encoding CE, Parallel Turbo code and Low density Parity Check (LDPC) coding schemes with a MultiUser Single Output MUSO Multi-Carrier Code Division Multiple Access (MC-CDMA) system over multipath fading channels. The decoding technique used in the simulation was iterative decoding since it gives maximum efficiency at higher iterations. Modulation schemes used is Quadrature Amplitude Modulation QAM. An 8 pilot carrier were
used to compensate channel effect with Least Square Estimation method. The channel model used is Long Term Evolution (LTE) channel with Technical Specification TS 25.101v2.10 and 5 MHz bandwidth bandwidth including the channels of indoor to outdoor/ pedestrian

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Jun 01 2018
Journal Name
Kerbala Journal Of Medicine
Polymerase Chain Reaction Testing in Comparison to Culture of Cerebrospinal Fluid for Diagnosis of Bacterial Meningitis in Children
...Show More Authors

View Publication
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of Population Therapeutics And Clinical Pharmacology
Accuracy of Office Hysteroscopy in Diagnosis of Endometrial Pathologies Compared to Ultrasound and Histopathology in Baghdad Teaching Hospital
...Show More Authors

View Publication
Scopus (7)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of Population Therapeutics And Clinical Pharmacology
Accuracy of Office Hysteroscopy in Diagnosis of Endometrial Pathologies Compared to Ultrasound and Histopathology in Baghdad Teaching Hospital
...Show More Authors

Background: Menstrual problems with all manifestations ranging from life-threatening bleeding to amen- orrhea are considered patterns of abnormal uterine bleeding (AUB), which is until now a popular reason for referral to the gynaecologic clinic and requires a special diagnostic tool. Objective: To assess the accuracy of hysteroscopy in diagnosing endometrial pathologies and to compare it with sonographic and histopathologic reports. Patients and Methods: A prospective study conducted in the Baghdad Teaching Hospital on 60 Iraqi females having varying complaints from abnormal uterine bleeding in pre- and post-menopausal women, infertility, and chronic pelvic pain with normal or abnormal ultrasound findings. Office hysteroscopy was done and

... Show More
View Publication Preview PDF
Scopus (7)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Thu Nov 01 2018
Journal Name
Journal Of Economics And Administrative Sciences
Administration Diagnosis of quality of work life dimensions: A survey of a sample of employees of the Northern Gas Filling Company in Nynawa
...Show More Authors

The primary objective of the present  research is to diagnose the most mportant imensions of quality of work life in a sample of individuals working in the Northern Gas Filling Company in Nynawa. The study sample consisted of 140 employees of the Northern Region Filling Company in even ,Through a questionnaire prepared for this purpose. The study concluded that there are five main factors that are considered to be measure of the quality of working life and are based on their importance: Empowerment, organizational health, internal work environment, motivation, development and training of workers. The study recommended that the organization should payattentio

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jun 30 2011
Journal Name
Al-kindy College Medical Journal
Antenatal diagnosis of myometrial invasion in anterior placenta previa by transabdominal color Doppler ultra sound
...Show More Authors

Background: The incidence of maternal mortality in
placenta previa accrete is 7%,and its preoperative
diagnosis is of a great value.
Objective: to evaluate the efficacy of transabdominal
color Doppler ultrasound in diagnosing placenta
previa accreta and inccreta. Color Doppler imaging
criteria used in: includes diffuse parenchymal
placental lacunar flow, focal intra parenchymal
placental lacunar flow and bladder uterine serosa
interphase hyper-vascularity.
Design: Prospective study on patients from
January2007 to January 2008.
Patients and method: 48patients with one caesarean
section or more and with persistent anterior placenta
previa diagnosed by transabdominal ultrasound were
examined by c

... Show More
View Publication Preview PDF
Publication Date
Thu Dec 10 2009
Journal Name
Iraqi Journal Of Laser
Diagnosis and Treatment of Cervical Intraepithelial Neoplasia with Carbon Dioxide Laser Therapy in Selected Patients
...Show More Authors

Female infection with HPV (human papilla virus) has been established as an essential cause of CIN (cervical intraepithelial neoplasia). The danger of transformation from CIN to frank malignancy should be considered. Objective: The goal of this study is to evaluate the effectiveness of CO2 laser vaporization of ectocervical lesion high grade squamous intraepithelial lesion (HGSIL). Patients and Methods: Four Female out of 150 affected with HGSIL lesions were submitted to CO2 laser vaporization and followed up in 4 months later, and 10 women with HGSIL lesion submitted to electrocautery diathermy for the comparison. Results: Among women treated by CO2 laser vaporization, 3 women had negative results (clear cervix), at 4 months follow up; o

... Show More
View Publication Preview PDF
Publication Date
Thu Dec 01 2022
Journal Name
Journal Of Environmental Engineering And Science
Performance evaluation of coronavirus closure on air quality over central, southern and northern parts of Iraq
...Show More Authors

When the number of confirmed coronavirus disease cases rose in Iraq in the middle of February 2021, the Iraqi government performed a closure approach to constrain mobility and factory operations and enforce social distancing. In this research, the concentrations of air components (PM2.5, PM10, nitrogen dioxide (NO2) and ozone (O3)), which represent herein the degree of air quality index, were recorded, drawn and evaluated over central (Baghdad, the capital), northern (Kirkuk Province) and southern (Basra Province) Iraq before and during the closure. The experimental duration of this research was 6 months (from 1 January 2021 to 30 June 2021), which

... Show More
View Publication
Scopus (4)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Fri Jun 30 2023
Journal Name
Ingénierie Des Systèmes D Information
Performance Evaluation of a Multi Organizations Secure Internet of Vehicles Based on Hyperledger Fabric Blockchain Platform
...Show More Authors

View Publication
Scopus (2)
Scopus Crossref
Publication Date
Fri Dec 31 2021
Journal Name
Journal Of Communicable Diseases
The Relation between RT-PCR and Chest CT Scan Sensitivity as Tools in the Diagnosis of COVID-19 Patients in Al-Najaf Province, Iraq
...Show More Authors

The typical test for diagnosis of severe acute respiratory syndrome coronavirus 2 is a reverse transcription-polymerase chain reaction (RT-PCR) technique, but the chest CT scan might play a complementary role at the first detection of Coronavirus Disease 2019 (COVID-19) pneumonia. Objectives: To determine the sensitivity of CT scan on patients with COVID-19 in Al-Najaf, Iraq, and to compare the accuracy of CT scan with that of RT-PCR technique. Material and Method: This is a prospective study. The patients suspicious of having COVID-19 infection and respiratory symptoms were registered. All patients were diagnosed by RT-PCR and chest CT. Diagnostic performance of CT was intended using RT-PCR as the reference sta

... Show More
View Publication Preview PDF
Crossref (1)
Scopus Crossref