The aim of this study was to evaluate the effects of local application of bisphosphonate gel and recombinant human bone morphogenic protein 2 gel, on titanium dental implant stability and marginal bone level. Twenty-seven patients with upper and lower missing posterior tooth/teeth were included in the study with a total of 71 implants that were used for rehabilitation. The implants were randomly divided into 4 groups: 3 study groups and 1 control. Group1; local application of bisphosphonate gel, group 2; local application of recombinant human bone morphogenic protein 2 gel, group 3; local application of a mixed formula of both gels. The gel application was immediately preimplant insertion, group 4; implant insertion without application of any medication. Using resonance frequency analyzer, implant stability was measured 4 times; primary, 8 weeks (second stage surgery), 12 weeks, and at least 14 weeks post functional loading. The level of the marginal bone around each implant were assessed using cone beam computed tomography. Four implants failed. Generally, there was a similar pattern of changes in implant stability over the study period in all groups and the stability was dependent on the healing time with no significant difference between groups. There was no significant treatment effect regarding marginal bone level differences of study groups against control, although there were significant differences on palatal and mesiodistal surfaces among the study (test) groups.
Recently the use of nanofluids represents very important materials. They are used in different branches like medicine, engineering, power, heat transfer, etc. The stability of nanofluids is an important factor to improve the performance of nanofluids with good results. In this research two types of nanoparticles, TiO2 (titanium oxide) and γ-Al2O3 (gamma aluminum oxide) were used with base fluid water. Two-step method were used to prepare the nanofluids. One concentration 0.003 vol. %, the nanoparticles were examined. Scanning Electron Microscopy (SEM), Atomic Force Microscopy (AFM) and X-ray diffraction (XRD) were used to accomplish these tests. The stability of the two types of nanofluids is measured by
... Show MoreThe olive tree, has been used it is important plant for the time being some of their parts on a large scale in the treatment of gastrointestinal disorders and stimulate circulation . Moreover, it is used as antibacterial material and also to address some of the respiratory system, diabetes, food preservation osteoporosis. This study involved the collection of olive leaves from different areas in Baghdad / Iraq. These leaves have been harvested, wash it, then dried and crushed, where the study aimed to identify the active ingredients and chemical elements in the olive leaf as well as its effect on the action of GOT enzyme .The study showed that the aqueous extracts (cold and hot) of the olive leaves powder are acidic in nature pH values
... Show MoreIt is often noted that disordered materials have different chemical properties to their more “ordered” cousins. Quantifying these effects in terms of thermodynamics is challenging in part because disordered materials can be difficult to characterize and are frequently relatively unstable. During the course of our experiments to understand the effects of disorder in catalysts for water oxidation we observed that many disordered manganese and cobalt oxide water oxidation catalysts directly oxidized peroxide in contrast to their more ordered analogues which catalyzed its disproportionation, that is, MnO2+2H+ +H2O2! Mn2+ +2H2O+O2(oxidation) versus H2O2!H2O+1=2 O2(disproportionation). By measuring the efficiency for one reaction over the oth
... Show MoreThis study was carried out to investigate the effects of magnetized water on accumulated infiltration depth. A test rig was designed and constructed for this purpose was installed at the water tests laboratory of the Department of Water Resources Engineering at the University of aghdad. The investigation was carried out by using two types of soil, different flow velocities throughout magnetizing device and different configuration of magnets over and under the water passage of the magnetizing device. The soils that were used in the experiments are clayey and sandy soils. Six different flow velocities throughout magnetizing device ranged between 0.29 to 1.19 cm/s and ten configurations of arranging the magnets over and under th
... Show MoreThe new complexes including Cu(II), Co(II), Ni(II), Pt(IV), and Pd(II) metals with 4,4'-(((1E,1'E)-1,4-phenylenebis(methaneylylidene))bis(azaneylylidene))bis(5-(4-chlorophenyl)-4H-1,2,4-triazole-3-thione) have been synthesized of utilizing us polystyrene (PS) photostability. The supplement (0,5 w / v%) was for the production of polystyrene ( PS) in the form of tetrahydrofuran (THF). Polystyrene films were exposing irradiation (250 – 380 nm) absorption light intensity of 6.02 x 10-9 ein dm-3 s-1 at room temperature, through the changes that occur to each of viscosity average molecular weight (Mv), main chain scission (S), degree of polymerization (DPn), weight loss %, hydroxyl index (lOH), carbonyl index (ICo) determined the photo stabiliz
... Show MoreBackground: The aim of this national oral health survey was to determine the prevalence of malocclusions due to some anomalies in the dentition among the 13 years old Kurdish students in sulaimani intermediate school. Materials and methods: The total sample was 950 (455 males and 495 females) which assessed by diagnostic set and special instrument. The clinical examination was mainly based on the definitions of Björk et al. Some variables were recorded as present or absent sometimes denoting the tooth or the teeth involved in malocclusion and their distribution according to the whole sample. Results: The results showed that 1)The most common extracted tooth was the mandibular first molar (2.9%). 2) At this age group the most common partial
... Show MoreBackground: The surface properties of the titanium alloy plays a significant role in the bond of the dental implant with living bone and modification of the implant surface could enhance osseointegration. This study was aimed to investigate the effect of different durations of heat treatment on the surface properties of titanium alloy for dental implants. Materials and methods: Twenty disks of (Ti-6Al-4V) alloy were prepared. The sample was divided into four test groups to study the effect of different duration of heat treatment to the surface topography; surface chemistry, titanium oxide layer thickness, blood contact angle, & blood drop diameter of titanium alloy samples were investigated to evaluate the effect of different durations of
... Show More