The aim of this study was to evaluate the effects of local application of bisphosphonate gel and recombinant human bone morphogenic protein 2 gel, on titanium dental implant stability and marginal bone level. Twenty-seven patients with upper and lower missing posterior tooth/teeth were included in the study with a total of 71 implants that were used for rehabilitation. The implants were randomly divided into 4 groups: 3 study groups and 1 control. Group1; local application of bisphosphonate gel, group 2; local application of recombinant human bone morphogenic protein 2 gel, group 3; local application of a mixed formula of both gels. The gel application was immediately preimplant insertion, group 4; implant insertion without application of any medication. Using resonance frequency analyzer, implant stability was measured 4 times; primary, 8 weeks (second stage surgery), 12 weeks, and at least 14 weeks post functional loading. The level of the marginal bone around each implant were assessed using cone beam computed tomography. Four implants failed. Generally, there was a similar pattern of changes in implant stability over the study period in all groups and the stability was dependent on the healing time with no significant difference between groups. There was no significant treatment effect regarding marginal bone level differences of study groups against control, although there were significant differences on palatal and mesiodistal surfaces among the study (test) groups.
In this study, derivatives of polyvinyl alcohol (PVA) grafted with phthalic anhydride (PhA) and dyes were prepared to produce polymeric materials of PVA-g-PhA, PVA-g-PhA-anthocyanin, PVA-g-PhA-bromophenol blue, and PVA-g-PhAthymol blue. The materials were characterised by FTIR and 1 H NMR spectroscopies. The crystallinity of the polymers was evaluated with powder X-ray difraction, and the thermal stability by thermogravimetric analysis (TGA). The synthetic procedure for the polymeric materials entailed the formation of esters. The FTIR spectra of the polymers confrmed their formation since the ester carbonyl group stretch was observed at approximately 1691–1716 cm−1 in each material. NMR spectroscopy confrmed the addition of t
... Show MoreEndothelin-I (ET-I) is one of the potent vasoconstrictors secreted from endothelial cells when needed. Many studies revealed the elevation of serum ET-I with human diabetes and microangiopathies. Since insulin resistance is a case of mixed diabetic and pre-diabetic cases, many risk factors beyond obesity and inflammation are proposed. The current study aims to demonstrate the association between serum ET-I and asymmetric dimethylarginine (ADMA) and insulin resistance in type 2 diabetes mellitus (T2DM). Sera of 73 subjects were enrolled currently (control= 35 subjects, and 38 with T2DM for more than 7 years), aged (40-60) years old, with distinct body mass index (BMI) ≤ 25 for control volunteers and (BMI) ≥ 25 for obesity and diabetes
... Show MoreMany condensed polymers [A1-A7] were prepared via reaction of (Ethylenediaminetetraacetic acid = EDTA), with different prepared imide-diamines by modification [ modification of amino acids and antibiotics (B1- B7)] Imide-diamines were prepared by chlorination of L-amino acids such as [ L-Histidine, L-Alanine, L-Valine, L-Glycine and L-Aspargine ] or selected antibiotics such as [Cephallixine monohydrate and Amoxilline ] with thionyl chloride at 0°C, then reacted with ammonia to obtain imidediamines [B1-B7] . The physical properties of all prepared condensed polymers [A1-A7], new prepared diamines [B1-B7] were studied and characterized by FT -IR spectroscope to certify the structural formulas. The thermal analysis (TGA, DTA) were studied, a
... Show MoreBackground: It has been well known that the success of mandibular implant- retained overdenture heavily depends on initial stability, retention and long term osseointegration this is might be due to optimal stresses distribution in surrounding bones. Types of mandibular implant- retained overdenture anchorage system and number of dental implants play an important role in stresses distribution at the implant-bone interface. It is necessary to keep the stresses below the physiologic tolerance level of the bone .since. And it is difficult to measure these stresses around bone in vivo. In the present study, finite element analysis used to study the stresses distribution around dental implant supporting Mandible implant retained overdenture Mate
... Show MoreBackground :Alkaline phosphatase (ALP) was a widely used marker for skeletal and hepatobiliary disorders, but its activity was also increased in atherosclerosis and peripheral vascular disease. Several study has showed that ALP activity was increased in the sera of diabetic patients. The current study was conducted to evaluate ALP activity in type 2 diabetic patients and optimum conditions for enzyme activity in their sera.Methods: This study was carried out at in AL-Yarmok hospital(diabetic center) between February /2009 and April /2009. Fifty two patients with type 2 diabetes have been enrolled. Besides BMI, WHR, serum fasting blood glucose, ALP, HbA1C,uric acid and lipid profile levels have been performed .The relationship bet
... Show MoreThe purpose of this study was to investigate the effect of omega-3 poly unsaturated fatty-acids co-administered with the therapeutic dose of lornoxicam on liver of healthy rats. Twenty-eight adults male rats weighing 180-200g were used in this study and the animals were randomly divided into four groups of seven rats each. Group I: negative control/rats intraperitoneally injected with normal saline in a dose 5ml/kg/day; Group II: rats intraperitoneally injected with lornoxicam at dose 0.7 mg/kg/day; Group III: rats orally-administered omega-3 only at a dose 185mg/kg/day; Group IV: rats co-administered omega-3 (185mg/kg/day) orally and in
... Show More